![uhlmann & zacher CX2192 Operating And Assembly Manual Download Page 18](http://html1.mh-extra.com/html/uhlmann-and-zacher/cx2192/cx2192_operating-and-assembly-manual_3269050018.webp)
CX2192
F
AULTS DURING OPERATION
17
8
Faults during operation
8.1
Fault indications
Function
Audible signal
Explanation
Memory fault /
configuration fault
▬ ▬ ▬ ▬ ▬ ●
5 long beeps,
1 short beep
Coupling error
▬ ▬ ▬ ▬ ▬ ● ●
5 long beeps,
2 short beeps
RTC fault (clock)
▬ ▬ ▬ ▬ ▬ ● ● ●
5 long beeps,
3 short beeps
Internal error
(unhandled interrupt)
▬ ▬ ▬ ▬ ▬ ● ● ● ●
5 long beeps,
4 short beeps
Internal error
(bus conflict)
▬ ▬ ▬ ▬ ▬ ● ● ● ● ●
5 long beeps,
5 short beeps
Internal error
(bus conflict)
▬ ▬ ▬ ▬ ▬ ● ● ● ● ● ●
5 long beeps,
6 short beeps
Internal error
(bus conflict)
▬ ▬ ▬ ▬ ▬ ● ● ● ● ● ● ●
5 long beeps,
7 short beeps
If the faults mentioned above occur repeatedly, then please contact the