Uhlenbrock Elektronik IntelliSound Manual Download Page 5

Table of the Configuarion Variables

CV Addr.

Range 1

897

900
901
902
903

904

905

906

907

908

909

910

911

912

913

914

915

920

921

922

923

924

925

Factory

Setting

1

85

1

255

0

3

2

4

1

0

0

0

8

0

0

0

0

128

5

5

128

27

4

Description

SUSI address range

1 = from 900 to 925

2 = from 940 to 965

3 = from 980 to 1005
Manufacturer ID
Software version
Speaker volume
function activates sound "x" (x = value of the CV)

x = 0     no sound is produced

x = 1     bell or horn #1

x = 2     whistle or horn #2

x = 3     motor (driving) sound

x = 4     uncoupling or door warning sound

x = 8     fade in/out all sounds
f1 activates sound "x"

where "x" is defined as per CV903/943/983
f2 activates sound "x"

where "x" is defined as per CV903/943/983
f3 activates sound "x"

where "x" is defined as per CV903/943/983
f4 activates sound "x"

where "x" is defined as per CV903/943/983
f5 activates sound "x"

where "x" is defined as per CV903/943/983
f6 activates sound "x"

where "x" is defined as per CV903/943/983
f7 activates sound "x"

where "x" is defined as per CV903/943/983
f8 activates sound "x"

where "x" is defined as per CV903/943/983
f9 activates sound "x"

where "x" is defined as per CV903/943/983
f10 activates sound "x"

where "x" is defined as per CV903/943/983
f11 activates sound "x"

where "x" is defined as per CV903/943/983
f12 activates sound "x"

where "x" is defined as per CV903/943/983
Configuration

Wert

Bit 0 = 0 The "chuff" sound of a steam locomotive is

0 *

controlled by the locomotive speed. However,

if a sensor is present, its information shall be

automatically used in order to synchronize the

"chuff" to the wheels.

Bit 0 = 1 The "chuff" sound of a steam locomotive is

0 *

controlled only by the sensor.

Bit 7 = 0 The module sound power output stage is

0

always turned on.

Bit 7 = 1 The module sound power output stage is

128 *

turned off if the sound is turned off.

Threshold for the load-dependend sound generation by

increasing load: 128 = load-dependend sound generation is off
Threshold for the load-dependend sound generation by

decreasing load: 128 = load-dependend sound generation is off
Threshold for exhaust fan for electric locomotive

255 = no exhaust fan sound
Threshold for brake squeal sound

255 = no brake squeal
Sensitivy to load changes

1 = reacts very quickly / 8 = reacts very slowly

Allowable

Values

1-3

-
-

0-255

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0-8

0, 1, 128,

129

0-128

0-128

0-255

0-255

1-8

CV Addr.

Range 2

897

940
941
942
943

944

945

946

947

948

949

950

951

952

953

954

955

960

961

962

963

964

965

CV Addr.

Range 3

897

980
981
982
983

984

985

986

987

988

989

990

991

992

993

994

995

1000

1001

1002

1003

1004

1005

All manuals and user guides at all-guides.com