Important

If  a  decoder  will  not  react  after  a  programming  cycle,  most  probably  its  address  has  been

altered inadvertently. To resolve this situation, either try all address settings, or Intellibox’s, or

Loktool‘s  address  search  function.
Wrong settings may be corrected by resetting the decoder using programming function 10.

Programming of Uhlenbrock Function Decoders

by a Märklin Central Unit

Follow exactly these steps when programming the decoder.

Do not push any other keys.

1. Preparation

s

Connect a Märklin central unit together with a control 80/80f or a control unit

to the track.

s

Switch off power supply for at least ten seconds, then switch on again.

All digital signals that may possibly interfere have died away.

s

Key in decoder address.

Every new decoder is set to 01.

s

Hold knob in direction reversal position for at least 8 secs.

Decoder changes over to programming mode.

2.  Programming  of  individual  functions

It does not matter whether functions are programmed individually or consecutively.

Functions not called up remain unaltered.
A lamp connected to the “f1” output will flash four times  to acknowledge a programming step.

2.1 Address

s

Call up function: Key in 01 and shortly push knob to reverse -

 a lamp will flash

s

Set value: Key in 01- 80 and shortly push knob to reverse -

 a lamp will flash

2.2 Selection of Data Format

s

Call up function: Key in 02 and shortly push knob to reverse -

 a lamp will flash

s

Set value: Key in 01 for the extended format (Gauge I format) and shortly push knob to reverse  - 

the lamp will flash

Key in 02 for the old data format (double frequency) and shortly push knob to reverse  - 

the lamp will flash

The old format renders functions “f1” to “f4”, the extended Motorola format will also utilize the direction info.

2.3 Output dimming

s

Call up function: for “f1” and “f2” - key in 03 and shortly push knob to reverse - 

the lamp will flash

for “f3”, “f4”, and “function” - key in 04 and shortly push knob to reverse - 

the lamp will flash

s

To set the duty cycle: 25% - key in 01 and shortly push knob to reverse - 

the lamp will flash

50% - key in 02 and shortly push knob to reverse - 

the lamp will flash

75% - key in 03 and shortly push knob to reverse - 

the lamp will flash

100% - key in 04 and shortly push knob to reverse - 

the lamp will flash

2.4 Defining of Flasher Outputs

s

Call up function: To assign frequency#1- key in 06 and shortly push knob to reverse - 

the lamp will flash

To assign frequency#2 key in 08 and shortly push knob to reverse - 

the lamp will flash

s

Set value: Flashing outputs-key in 01-31and shortly push knob to reverse - 

the lamp will flash

No flashing at all-key in 32 and shortly push knob to reverse - 

the lamp will flash

The code value is derived from an addition of the output ‘weights’: f1 = 1, f2 = 2, f3 = 4, f4 = 8, function = 16.

When e.g. f1 and f3 are set to flashing, the code value must be 05 (1 + 4).

2.5 Setting the frequency

s

Call up function: To call frequency#1 - key in 07 and shortly push knob to reverse - 

the lamp will flash

To call frequency#2 - key in 09 and shortly push knob to reverse - 

the lamp will flash

s

Set value: Rate 8 times per sec - key in 01 and shortly push knob to reverse - 

the lamp will flash

Rate 1 time per sec - key in 08 and shortly push knob to reverse - 

the lamp will flash

Rate 1 time per 8 sec - key in 64 and shortly push knob to reverse - 

the lamp will flash

The allowed values range from 01 -79. In analogy to 2.4 the actual flash period is determined by adding the rate weights.

2.6  Reset

s

Key in 10 and shortly push knob to reverse - 

the lamp will flash

The decoder will be set to the preset values: Address 01, extended Motorola data format,

no flashing, frequency rates set to 1 time per sec, and 100% duty cycle.

3. Leaving Programming Mode

s

 Key in 80 and shortly push knob to reverse.

Decoder returns to its normal operating mode.