background image

PRODUCT USER GUIDE

MicroLED 1000P Light Source

PLEASE READ THIS USER GUIDE BEFORE INSTALLING

OPERATING

OR PERFORMING MAINTENANCE ON THE LIGHT SOURCE UNIT

E357731

Rev: C2

Summary of Contents for MicroLED 1000P

Page 1: ...PRODUCT USER GUIDE MicroLED 1000P Light Source PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE LIGHT SOURCE UNIT E357731 Rev C2 ...

Page 2: ...urce is not replaceable When it reaches end of life the whole unit must be replaced Type Y Attachment If the external flexible cable or cord of this luminaire or associated PSU driver is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person to avoid a hazard Location Do not locate this light source closer than 200mm from any flammable surfa...

Page 3: ...suit UK European and USA power outlets The UK model is shown below POWER SUPPLY REQUIREMENTS Plug the jack plug into the socket in the back of the light source and the unit is now ready for connection INSTALLATION 3 UFO LIGHTING This luminaire supplied with a separate mounting plate If using the mounting plate refer to the fitting instructions supplied with it ...

Page 4: ...lour 2 Colour 3 Colour 4 Colour 5 Colour 6 Colour 7 1 White Red Orange Jade Green Cyan Blue 2 Red Orange Jade Green Cyan Blue White The light source is controlled using the 2 push buttons on the rear of the unit The upper button stops and starts the colour cycle The lower button is used to select the cycle speed as follows Push the lower button repeatedly until the colour white is displayed The li...

Page 5: ... but LED power indicator is still illuminated LED array failure Replace Light Source Poor light output on fibre Unit needs cleaning Carefully clean LED Lens with dry cloth Clean fibre common end Fibre port connector not plugged in correctly Ensure plugged in correctly and secured with locking screw Stationary on one colour Upper button has been pressed Press upper button once LED driver has failed R...

Page 6: ... Maintenance Undertaken Note a record of all maintenance MUST be kept in the table above indicating what maintenance was undertaken and when This MUST be dated for warranty purposes MAINTENANCE MICROLED 1000P USER GUIDE 6 ...

Page 7: ... Min Ambient Temp 10 C Max Ambient Temp 45 C LED Array Type RGBW LED Array Power 2 5W LED Array Model Cree XLamp MC E LED Array Life L70 B10 50 000 hours 25 C Wavelength and Luminous Flux Red 625nm 45lm Green 530nm 93lm Blue 460nm 12lm White 3500K 120lm Colour Change Functionality Push button manual colour change Supply Voltage 90 264Vac Mains Running Current 0 03A 240Vac Mains Voltage VA rating 8...

Page 8: ...ndsfactory AG Gutenbergstraße 1 85737 Munchen Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting com Universal Fibre Optics Ltd Home Place Coldstream TD12 4DT UK 44 0 1890 883416 www ufo lighting ...