![UFO Mercury MER3000 0-10V User Manual Download Page 13](http://html1.mh-extra.com/html/ufo/mercury-mer3000-0-10v/mercury-mer3000-0-10v_user-manual_835105013.webp)
Universal Fibre Optics
13
ADDITIONAL TROUBLESHOOTING (0-10V MODELS ONLY)
Problem
Probable Causes
Remedy
Unit not repsonding to 0-
10V commands
0-10V cable fault
Refer to manual diagram for
correct termination.
Carry out continuity check.
Carry out voltage / polarity
check
Controller fault
Carry out voltage / polarity
check at controller.
Repair / replace as necessary
0-10V LED PCB failure
Replace 0-10V PCB
No 0-10V signal present
Controller off or failed
Check controller. Ensure 0-
10V signal present
0-10V cable faulty
Carry out voltage and
polarity check on mini XLR
plug. Repair as necessary