The UFO IP-01 enclosure is available in two power source variants: 
 

1.

 DC supply (12V DC) denoted by the model number having the suffix DC. This version has the 

light source 12V DC PSU mounted remotely external to the enclosure and the unit is powered 
from the DC supply to a terminal block inside the enclosure. For this version, the PSU can be 
supplied by UFO or the customer. For the USA and Canada, if supplied by the customer the PSU 
must be UL listed and not only suitable in terms of correct voltage and wattage but also suitable 
for the environment/location in which the PSU is to be installed. (See figure 1 below. 
 

2.

 Mains supply (240V 50Hz) denoted by the model number having the suffix AC. This version 

has the light source 12V DC PSU mounted inside the enclosure and the unit is powered from a 
mains supply to a fused terminal block inside the enclosure. (See figure 2 on next page). 
 

INTRODUCTION

3

UFO

 

LIGHTING

FIGURE

 

1

 - 

DC

 

POWERED

 

VARIANT

Summary of Contents for IP-01

Page 1: ...PRODUCT USER GUIDE IP 01 Weatherproof Enclosure PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ENCLOSURE Rev C1...

Page 2: ...person familiar with the construction and operation of the product and the hazards involved When used in the USA or Canada cables connected to this enclosure must be UL listed and not only suitable f...

Page 3: ...the customer For the USA and Canada if supplied by the customer the PSU must be UL listed and not only suitable in terms of correct voltage and wattage but also suitable for the environment location i...

Page 4: ...INTRODUCTION 4 FIGURE 2 AC POWERED VARIANT IP 01 WEATHERPROOF ENCLOSURE USER GUIDE...

Page 5: ...rce Model Power Variant Max Wattage UFO IP01 MIC1000 AC MicroLED 1000 240VAC 50Hz 5W UFO IP01 MIC1000 DC MicroLED 1000 12V DC 5W UFO IP01 MIC4000 AC MicroLED 4000 240VAC 50Hz 5W UFO IP01 MIC4000 DC Mi...

Page 6: ...ust be located out of direct sunlight and there must be a minimum of 300mm 12 of space around all sides to allow for air circulation and to prevent overheating Mounting the enclosure in any other way...

Page 7: ...te that unless UFO are installing the unit then we do not supply fixings This is due to the large variance of surface types the enclosure may be mounted to 4 Follow the instructions for the chosen fix...

Page 8: ...eal Do not overtighten the nylon gland Never run the luminaire with the fibre optic harness out of the aperture Loosen the gland for the DMX cables and feed the cables carefully through the gland leav...

Page 9: ...s and feed the cables carefully through the gland leaving sufficient slack inside the enclosure to reach the back of the light source Tighten the gland and fit RJ45 connectors to the cables as detaile...

Page 10: ...cator on Light source not connected correctly Refer to Troubleshooting section in light source user guide Light source not set up correctly Refer to Operation section in light source user guide DC enc...

Page 11: ...lity for any loss or damage that occurs due to incorrect mounting Port Connector Size 30mm Fibre Type Glass or PMMA Material Finish Sheet Steel RAL7035 Overall Dimensions 300mm x 250mm x 155mm 11 8 x...