Controls and connectors 

 

 

 

Power switch 

 

Connects power supply to Model 2283FT(i);  
should be left in OFF position when instrument is 
not in use. 

 

Power meter 

 

Should read in the green zone when power switch 
is in ON position. 

 

Power connector (back panel) 

 

Connect supplied wall-mount transformer power 
supply to this jack.  

 

 
 

 

 

Four-pin input connectors (back panel) 

 

Connect the two supplied Fetrode™ buffer 
assemblies to these black receptacles, which are 
located on the left side of the back panel. 

 

Green ground reference connector (back panel) 

 

Plug the supplied ground reference lead into this 
0.080” jack, located between the two four-pin 
Fetrode™ connectors. 

 

Amplification switch 

 

Use this four-position rotary switch to select the 
amplification (gain) factor applied to the Fetrode™ 
buffer assembly outputs. 

 

Choices are   

o

 

X10 

o

 

X100 

o

 

X1000 

o

 

X10000 

Summary of Contents for FETRODE 2283FT

Page 1: ...a unique temperature compensated amplifier with an extremely high input impedance and a very low output impedance The circuitry is built with state of the art surface mount technology into a miniature enclosure that can be snapped onto any high quality electrode This innovation places signal buffering directly on the active electrode site In so doing the Fetrode virtually eliminates artifacts due ...

Page 2: ...4 Four pin input connectors back panel Connect the two supplied Fetrode buffer assemblies to these black receptacles which are located on the left side of the back panel Green ground reference connector back panel Plug the supplied ground reference lead into this 0 080 jack located between the two four pin Fetrode connectors Amplification switch Use this four position rotary switch to select the a...

Page 3: ...ng or to wear tight fitting clothing that cannot move enough to generate noise You must use ground reference electrode Locate it roughly equidistant from active electrode sites those equipped with Fetrode assemblies Do not abrade active electrode sites You may need to abrade the ground electrode site if you are recording low frequency low level signals when a large 50 60 Hz powerline noise source ...

Page 4: ...st defects in materials and workmanship to the original purchaser for a period of one year from the date of original purchase This warranty is void if our inspection shows the equipment has been tampered with or installed at variance with factory designated procedures or has been subjected to negligence misuse or accident beyond normal usage or has had the serial number altered defaced or removed ...

Reviews: