16
• Only specialized personnel should perform repairs to this electrical appliance. Any incorrectly performed repair
can lead to considerable hazards for the user. In the event of repair, please always contact our aftersales service.
Failure to observe these instructions will lead to the total loss of the product warranty..
TROUBLESHOOTING GUIDE
Possible operating anomalies
INCIDENT
CAUSE
SOLUTION
The device
does not
work.
Appliance not switched on.
Switch on the appliance using the speed button.
The unit is on but the selected temperature level
in the thermostat is lower than the temperature
of the room.
Increase the temperature level of the thermostat (D)
Information requirements for electric local space heaters
CP1800IP
Item
Symbol
Value Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only
Nominal heat output
P nom
1,6 -
1,8
KW
Manual heat charge control, with integrated thermostat
No
Minimum heat output
(indicative)
P min
0,9
KW
Manual heat charge control with room and/or outdoor
temperature feedback
No
Maximum continuous
heat output
P max,c
1,8
KW
Electronic heat charge control with room and/or outdoor
temperature feedback
No
Auxiliary electricity
consumption
Fan assisted heat output
No
At nominal heat
output
el max
N/A
KW
Type of heat output/room temperature control (select one)
At minimum heat
output
el min
N/A
KW
single stage heat output and no room temperature control No
In standby mode
el SB
0
KW
Two or more manual stages, no room temperature control No
with mechanic thermostat room temperature control
Yes
with electronic room temperature control
No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
No
Other control options (multiple selections possible)
room temperature control, with presence detection
No
room temperature control, with open window detection
No
with distance control option
No
with adaptive start control
No
Summary of Contents for calefactor plano CP1800IP
Page 2: ...2 D C B A...
Page 23: ...23 UFESA 1 UFESA C D 8 t UFESA...
Page 24: ...24 t a 3 3 8 t 3 8...
Page 25: ...25 4 2...
Page 26: ...26 IPX1 T B B TRENDS SL 1 2 50 1 50 cm 3 60...
Page 27: ...27 4 5 C 6 D CP1800IP...
Page 30: ...30 4 IPX1 B BTRENDSSL 1 2 50 50 06 3...
Page 31: ...31 UFESA UFESA 1 A B C D 8 3 8 3 3 8...
Page 32: ...32...
Page 33: ...33 WEEE EU 19 2012...
Page 36: ...36 B B TRENDS SL e B B TRENDS SL 1999 44 B B TRENDS SL B B TRENDS SL...
Page 37: ...37 B B TRENDS SL 23 2003 B B TRENDS SL 2003 10 B B TRENDS SL...