background image

Physical Characteristics

Functional Characteristics

RLD10-MAN    

P. 4

Size: Height by Width by Depth

(with probe wrapped around boot)

Probe length: fully extended

Weight (battery installed)

8” x 4” x 1 1/2”

18 1/2” (47cm)

14.1 Oz (400g)

Power requirements

Average battery life (Continuos use)

Leak detection sensitivity

Sensor

Duty cycle 

Typical response time

Warm up period

Sensor output (voltage/current)

Visual level indicators

One 9 volt alkaline battery

Approximately 8 hours

.4 Oz/year (11 grams/year) R134A 

using LS20 leak standard

Corona discharge

Continuos

Less than 1 second 

(allows for 1”/sec seek rate)

10 second average

A. No -load high voltage: 2500V ±10%
B. Current: 24 mA
C. Loaded high voltage: 2400V ±50V
(loaded with 100.0 M Ohms

Four tic-rate scaled LED indicators

changing from green to yellow to light

red to red (indicating relative, 

not specific quantities)

Reviews: