UEi Phoenix Series Instruction Manual Download Page 5

M a i n t e n a n c e

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified 
personnel only. Improper repair or service could result in physical 
degradation of the meter. This could alter the protection from electrical 
shock and personal injury this meter provides to the operator. Perform 
only those maintenance tasks that you are qualified to do.

Cleaning

Pe r i o d i cally clean your meter’s case using a damp cloth. 

DO NOT

u s e

a b rasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of the
s t r u c t u ral components.

Battery Replacement

Remove screws from battery compartment cover on back of meter and
remove cover. Replace batteries with fresh batteries paying attention to
p o l a r i ty position. Replace cover and screw s .

Specifications

AC Amps Measurement  - Jaw input (45Hz to 400Hz)

*DL269

400A range only

*DL289

45Hz to 400Hz True RMS (Crest factor <3:1)

DC Low Amps Measurement (test lead input)

AC Low Amps Measurement (test lead input, 45Hz to 400Hz)

*DL289

45Hz to 400Hz True RMS (Crest factor <3:1)

DC Volts Measurement

AC Volts Measurement (45Hz to 400Hz)

*DL289

45Hz to 1KHz True RMS (Crest factor <3:1)

Ohms Measurement

Diode Test

Capacitance Measurement

Temperature Measurement (DL279 & DL289 only)

Frequency Measurement

Minimum frequency: 0.5Hz, DC V offset should be zero
Sensitivity: > 1.0V rms

Duty (%) Cycle Measurement

0.5Hz to 100kHz (pulsewidth > 2µ sec)

Continuity Measurement

Physical Specifications

DL269/DL279/DL289-MAN     

P. 4

Range

Resolution

Accuracy

Overload Protection

40A

0.01A

±2.9% +15 dgts

600V

400A

0.1A

±1.9% +8 dgts

Range

Resolution

Accuracy

Overload Protection

400µA

0.01µA

±1.2% +3 dgts

2000µA / 600V

2000µA

0.1µA

Range

Resolution

Accuracy

Overload Protection

400µA

0.01µA

±2.0% +5 dgts

2000µA / 600V

2000µA

0.1µA

±1.5% +5 dgts

Range

Resolution

Accuracy

Overload Protection

400mV

0.1mV

±0.5% +4 dgts

600V

4V

1mV

40V

10mV

400V

100mV

1000V

1V

±0.8% +10 dgts

Range

Resolution

Accuracy

Overload Protection

4V

1mV

±2.0% +5 dgts

600V

40V

10mV

400V

100mV

750V

1V

Range

Resolution

Accuracy

Overload Protection

400

Ω

100m

Ω

±1.0% +4 dgts

600V

4k

Ω

1

Ω

40k

Ω

10

Ω

400k

Ω

100

Ω

4M

Ω

1kΩ

40MΩ

10kΩ

±2.0% +4 dgts

Range

Open Circuit Vo l t a g e Test Current (typical) Overload Protection

2.0V

< 3.0V DC

0.25mA

600V

Range

Resolution

Accuracy

Overload Protection

40nF

0.01nF

±3.5% +6 dgts

600V

400nF

0.1nF

4µF

0.001µF

40µF

0.01µF

400µF

0.1µF

4000µF

1µF

Range

Resolution

Accuracy

Overload Protection

-22˚ to 14˚F

0.1˚F

±5.4˚F

30V

(-30˚ to -10˚C)

(0.1˚C)

(±3.0˚C)

15˚ to 752˚F

0.1˚F

±1.0% +3.6˚F

(-9˚ to 400˚C)

(0.1˚C)

(±1.0% +2.0˚C)

Range

Resolution

Accuracy

Overload Protection

9.999Hz

0.001Hz

±0.1% +4 dgts

600V

99.99Hz

0.01Hz

999.9Hz

0.1Hz

9.999kHz

1Hz

99.99kHz

10Hz

Range

Accuracy

Overload Protection

01. to 99.9%

±(0.2% per kHz +0.1%) +5 count

600V

Open Circuit voltage <2.7V

Overload Protection

Threshold Approximately <20

Ω

600V

Operation temperature

32˚ to 104˚F (0˚ to 40˚C)

Storage temperature

-4˚ to 140˚F (-20˚ to 60˚C)

Relative humidity

0% to 80% at 32˚ to 95˚F (0˚ to 35˚C),
0% to 70% at 32˚ to 131˚F (0˚ to 55˚C)

Temperature coefficient

Nominal 0.1 x (Specified accuracy) / ˚C
(<18˚ or >28˚C ; <64˚ or >82˚F)

Altitude

Operating - up to 2000m
Storage - 10000m

Pollution degree

2

Installatin category

CAT III 600V, CAT II 1000V

Certifications

UL & cUL standard UL 3111-1 Listed