background image

OPEN

OPEN

INSTRUCTION MANUAL

ENGLISH

NCV3

NCV3

Non-Contact Voltage Tester

Manual de instrucciones

ESPAÑOL

Detector de Tensíon Sin Contacto

Copyright © 2018 Kane USA, Inc. All Rights Reserved.

WARRANTY

The NCV3 is warranted to be free from defects in materials 
and workmanship for a period of one year from the date of 
purchase. If within the warranty period your instrument should 
become inoperative from such defects, the unit will be repaired 
or replaced at UEi’s option. This warranty covers normal use 
and does not cover damage which occurs in shipment or 
failure which results from alteration, tampering, accident, 
misuse, abuse, neglect or improper maintenance. Batteries and 
consequential damage resulting from failed batteries are not 
covered by warranty.

Any implied warranties, including but not limited to implied 
warranties of merchantability and fitness for a particular 
purpose, are limited to the express warranty. UEi shall not be 
liable for loss of use of the instrument or other incidental or 
consequential damages, expenses, or economic loss, or for any 
claim or claims for such damage, expenses or economic loss.

A purchase receipt or other proof of original purchase date 
will be required before warranty repairs will be rendered. 
Instruments out of warranty will be repaired (when repairable) 
for a service charge.

This warranty gives you specific legal rights. You may also 
have other rights, which vary from state to state.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment 

and its accessories shall be subject to separate 
collection and correct disposal.

GARANTÍA

El NCV3 está garantizado a no tener defectos en materiales 
y fabricación por un periodo de uno año a partir de la fecha 
de compra. Si dentro del periodo de garantía el instrumento 
quedara inoperante debido a tales defectos, se reparará la 
unidad o se sustituirá, a opción de UEi. Esta garantía cubre el 
uso normal y no cubre daños que ocurran en el envío o fallas 
resultantes de alteraciones, modificaciones, accidentes, uso 
indebido, maltrato, negligencia o mantenimiento indebido. Las 
baterías y el daño consecuente resultante de baterías falladas 
no están cubiertos por la garantía. 

Toda garantía implícita, inclusive entre otras las garantías 
implícitas de comerciabilidad e idoneidad para un fin en 
particular, se limitan a la garantía expresa. UEi no se hace 
responsable por la pérdida de uso del instrumento u otros daños 
fortuitos o consecuentes, gastos, o pérdida económica, ni por 
ninguna reclamación o reclamaciones por dichos daños, gastos o 
pérdida económica. 

Se exigirá un recibo de compra u otro comprobante de la fecha 
original de compra antes de realizar las reparaciones bajo 
garantía. Los instrumentos fuera de garantía serán reparados 
(cuando sean reparables) cobrando un 
cargo por el servicio. 

Esta garantía le concede derechos legales específicos. También 
puede tener otros derechos que varían de un estado a otro.

DESCARTE / RECICLADO

 PRECAUCIÓN:

 

Este símbolo indica que el equipo 

y sus accesorios estarán sujetos a una recolección 
separada y descarte correcto.

17224 • RB 0518

1000V

CAT IV

1000V

CAT IV

FEATURES

GENERAL SPECIFICATIONS

• Operating Temperature: 

14˚ to 122˚F (-10˚ to 50˚C)

• Storage Temperature 

-4˚ to 140˚F (-20˚ to 60˚C)

• Operating Humidity:

 < 80%

• Pollution Degree:

 2

• Dimensions: 

1.06 X 6.1 X 0.78

• Item Weight: 

0.09

• CAT Rating:

 CAT IV 1000V

• Certifications: 

cETLus,

 

STD61010-1, 61010-2-030,

certified to CAN/CSA C22.2

• Battery Type:

 AAA X 2

IMPORTANT SAFETY WARNINGS

 

 

WARNING

Read entire Safety Notes section regarding potential hazard 
and proper instructions before using this unit. In this manual the 
word “

WARNING

” is used to indicate conditions or actions that 

may pose physical hazards to the user. The word “

CAUTION

” 

is used to indicate conditions or actions that may damage this 
instrument. 

•  Do not use the unit to detect an AC voltage below 24V AC or

above 1,000V AC. Do not use the unit for DC voltage
detection.

•  If there are several lines, such as 2-phase wires or 3-phase

wires, separate them far enough apart from each other and
perform detection on each line.

•  Because the unit’s range and distance can affect detection

alerts, the object under test may be live even if the visual
and audible alerts do not activate. To avoid electric shock 
and personal injury, do not touch non-insulated conductor
with hand or skin.

•  Due to interference caused by the electric field in the 

environment, the unit may give an alarm even if the object 
under test does not contain AC voltage.

•  Do not use the unit if it is damaged or operates abnormally.
•  Do not use the unit for detection on any shielded conductor.
•  NCV3 may alarm near objects with static charge or iron

objects near an AC current.

SYMBOLS

AC (Alternating current)

Double Insulation (Protection to Class II)

Risk of Electrical shock

OPERATING INSTRUCTIONS

Turn On:

 

• Press button to turn on.
• Single “beep” and steady Green LED indicates ready.

Function

On

Low Voltage 
24V to 48V 

High Voltage 
48V to 1000V 

Off

Visual 
Alert

Solid 
GREEN 
LED

Slow-Blinking 
RED LED

Solid
RED LED

None

Audible 
Alert

Single 
Beep

Slow Beeps

Fast Beeps

None

•  Worklight: Press button for 1~2 seconds to activate or

deactivate.

•  Auto power off: Powers down after 5 minutes of non-use

to save battery life.

Battery Replacement:

 When turning on, if Green LED is dim, 

blinking or does not light, this indicates immediate battery 
replacement needed.
To replace battery, remove cover as indicated below. Remove old 
batteries and dispose of properly. Install 2 new (AAA), observing 
proper polarity. Replace cover.

PRESS

SLIDE

•  24 to 1000V AC detection
•  Hi/Lo voltage detection
•  Visual LED alert
• Audible alert

• Worklight
• Magnetic mount
•  Auto power off
•  Low battery indication

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Reviews: