OPERATING INSTRUCTIONS

To turn the meter on press the power button for 2 seconds.

1. Zero the meter

Prior to use, the meter must be zeroed. To do this, ensure 

the meter is in a non-pressurized area, and press and hold 

the ‘ZERO’ button for approximately four seconds. The 

display will show ‘888’ to indicate that the zero function 

has occurred.

2. Measure Pressure

Connect the flexible tube between the meter and the 

pressure source.  

When performing single input measurement use the EM151 

single port or the EM201B positive input.  The EM201B 

positive input is to the right when looking at the front of the 

meter.  Positive pressures will display as positive results, 

and negative pressure will display a negative result.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for EM151

Page 1: ...EM201B Low Battery PSI In Wg mBar hPa EM151 Scale Hold for OFF EM151 EM201B Electromic Manometers INSTRUCTION MANUAL www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...and EM201B provide a simple time saving alternative to U tube pressure measurements Use the UEi EM151 EM201B to measure gas supply and draft pressures in residential or light commercial properties The...

Page 3: ...fy and repair the source of the leak before continuing with the test In the interest of safety this instrument should only be used by trained competent professionals who know the hazards and consider...

Page 4: ...r 20 minutes 3 year limited warranty EM201B Dual input differential measurement to 60 In WG Measures in In WG mBar PSI and Pa auto range to hPa Ruggedized including rubber boot with integral magnet Au...

Page 5: ...cate that the zero function has occurred 2 Measure Pressure Connect the flexible tube between the meter and the pressure source When performing single input measurement use the EM151 single port or th...

Page 6: ...nts Place the positive port in the area expected to have a higher pressure and the negative port in the area of lower expected pressure 3 SCALE To select the desired units press SCALE Repeated presses...

Page 7: ...lay hold feature Press this during reading to freeze the display Press again to return to actual measurement 6 BACKLIGHT EM201 ONLY The EM201B has a backlit display Press to turn on or off the back li...

Page 8: ...ndensing Battery life 50 hours min with alkaline battery EM201B Measurement range 60 to 60 In WG Minimum pressure displayed 0 01 In WG Accuracy 0 03 3 In WG 1 rdg 3 In WG Resolution 0 001 9 999 to 9 9...

Reviews: