UEi ECT690 Instruction Manual Download Page 2

Introduction

Use the ECT690 to perform quick checks of AC Volts, DC Volts, and
Continuity. LED’s indicate Voltage level and DC polarity, tone provides
audible indication of Continuity.

Features include

• AC Volts 12 to 690
• DC Volts 6 to 220
• Continuity
• One year limited warranty

Safety Notes

• Never use the tester if it or its test leads appear damaged.
• Never apply more than 1000V DC or 1000V AC rms. between 

any terminal and earth ground.

• I n d i cates dangerous voltage present at the terminals if the LED 

turns on.

• When using the probes, do not touch the metal probe tips.
• Disconnect the live test lead before disconnecting the common 

test lead.

• Before each use, verify the tester’s operation by measuring a 

known voltage.

Operating Instructions

Automatic Operation

The tester automatically turns on when you place the probes across a
complete circuit. The tester selects continuity or DC or AC voltage 
mode based on the resistance or voltage between the probes. The
tester automatically turns off when you remove the probes from the
complete circuit.

Measuring Voltage

Connect test leads across the source or load under measurement. The
LEDs turn on at between 70% and 100% of their rated voltages.

DC Voltage

AC Voltage

1000V DC maximum

1000V rms. maximum
45 Hz to 66 Hz

Testing for Continuity

Turn off circuit power before testing. Beeper indicates shorts lasting 
1 ms or longer.

M a i n t e n a n c e

Battery Test and Replacement

Replace the batteries when touching the leads together no longer turns
on the continuity LED. Reference to (Fig 1) to replace batteries.

NOTE:

Disconnect probes

from voltage.

NOTE:

Do not 

over-tighten screws

Observe battery polarity.

S p e c i f i c a t i o n s

ECT690-MAN    

P. 1

Function

Range

Accuracy

AC Voltage (V)

12, 24, 48, 110, 230, 400, 690

-30% to 0% of reading

DC Voltage (V)

6, 12, 24, 36, 48, 110, 220

-30% to 0% of reading

Continuity Test

Audible threshold 0 - 85

Ω

, Continuity beeper 2KHz

Maximum Voltage

Between any terminal and earth ground: 1000V DC, 
1000V AC rms, overvoltage category III

Input Impudence

1M

Ω

Relative Humidity

90% (0˚-30˚C), 75% (30˚-40˚C), 45% (40˚-50˚C)

Battery Type and Life (2) “AA”, 350 hours with NEDA 15F r IEC R6
Safety

Complies with EN61010-1:1993 for use in overvoltage 
CAT III environments

EMC Regulations

EN50081-1, EN50082-1

(Fig 1)

Continuity

Beeping

Continuity

+VDC

-VDC

VDC

+

-

6

12

24

-

+

+VDC

-VDC

VDC

6

12

24

VAC

VAC

12

24

24

48

110

230

400

12V DC

12V DC

110V AC

Open

Short          or          0 - 85K

Ω

Reviews: