  LCd dISPLAY

 

  1.  Primary LCD: Display T1 (1st thermocouple reading) or T1 - T2
  2.  Secondary LCD: Display T2

4

  OPERATION

• 

POWER ON/OFF

Note:

Make sure you have plugged in the thermocouple probe before 

turning on. 

Press and hold PWR button to turn on the meter. While the meter is 

on, press PWR button to turn off the meter.

• 

SLEEP MODE (AUTO POWER OFF)

The meter will turn off automatically after 15 minutes if no buttons 

are pressed. To disable auto power off function, when the meter 

is off, press and hold “

HOLD

” button then press “

PWR

” button 

to turn on the meter, the primary LCD shows the following. Sleep 

mode is now disabled.

• 

TAKING MEASUREMENT

Connect thermocouple. If probe is open or not connected, the LCD 

will show ”---”. 

• 

DIFFERENTIAL (T1 - T2)

Press "

MODE

" to display differential. Press "

MODE

" again to 

return to normal display.

    

•  MAX / MIN

Press 

MAX / MIN

 button to change operation mode from live 

data -> MAX -> MIN -> back to live data. Corresponding value will 

display on the LCD. These values will reset at power on or when 

performing a reset on MAX/MIN.

Reset MAX/MIN

: Press Max/Min button for 2 seconds to reset 

MAX/MIN analysis value. The MAX/MIN value is updated to 

current reading.

•  DATA HOLD

Freeze display of basic measurements or disable. Press HOLD 

button again to go back to the temperature reading.

• 

CHANGE UNIT

Press 

UNIT

 button to change unit ˚C or ˚F. The meter default 

temperature unit is ˚F. The meter will default to last selected scale.

1

  INTROdUCTION

Thank you for purchasing the UEi DTK2 dual input K type 

differential thermometer. This thermometer features a built-in 

microprocessor and high resolution analog to digital converter 

chip. The thermocouple probe responds very quickly to a wide 

range of temperature measurements. The industry standard mini 

thermocouple jack accepts a wide selection of probe types.

FEATURES

•  Dual input with differential (T1 - T2)

•  Min / Max capture (T1 & T2)
•  Auto power off with disable feature (15 minutes) 

•  Large LCD screen 

•  Complete with bead wire temperature probes and 9V battery

•  ˚C / ˚F select function 

•  Magnetic mount

INCLUDES

•  Meter

•  9V battery

•  Operation manual

•  ATT29A K-type bead probe (2)

•  Pouch 

2

  KEYPAd (CONTROLS)

T1

-

T2

HOLD MAX MIN 

2

1

MODE

SET

PWR

MAX

MIN

UNIT

HOLD

PRESS “

UNIT

” TO SELECT ˚C/˚F. 

Freeze display 

Press “

MODE

” to change operation mode T1 or T1-T2. 

The corresponding reading will display on the primary 

LCD. The secondary LCD will always display T2.

Press and hold “

PWR

” to turn on the meter or 

press it to turn off the meter. The meter will turn off 

automatically after 15 minutes if you don’t press any 

key. Press “

HOLD

” and “

PWR

” buttons to disable  

Auto sleep mode. 

Press “

MAX/MIN

” to change operation mode

from live data -> Max.-> Min.-> back to live date. The 

corresponding value will display on the LCD. The value 

is calculated since powered on or reset. 

Press and hold to enter ice-point calibration. (Please 

refer to section 

5

 to ensure correct calibration.)

Press 

UNIT

 

Single Input: (Top View)

T2

MIN

MAX 

HOLD

 

5

  AUTOMATIC ICE-POINT CALIBRATION

The DTK2 has an automatic ice-point calibration function. Please 

follow these steps to calibrate your meter to the thermocouple 

probes.

•  ITEMS NEEDED:

 

1.  DTK2 Thermometer

 

2.  Two k-type probes

 

3.  Crushed ice/water mixture 

 

 

(distilled water recommended if available)

•  CALIBRATION PROCEDURE

1.  Connect both probes to the DTK2
2.  Place probe tips in the crushed ice/water mixture
3.  Power on the DTK2
4.  Press and hold SET for five seconds.
  a.  The meter will enter ice-point calibration and 0.0°C will  

    flash on both T1 and T2 readings
5.  Stir the ice bath with the probes submerged for one minute
6.  Continue stirring the ice/water mixture until the readings   

  return to normal measurement (flashing will stop)

  The ice-point calibration is now complete.

DTK2

   75.9

 

°

f

   75.9

 

°

f

T1
K

T1
K

76.1

°

f

76.1

°

f

T2
K

T2
K

Differential Thermometer

WARNING!

 Always connect thermocouple before turning the 

unit on for most accurate readings.

WARNING!

 Make sure to plug sensor with correct polarity. 

Do not be alarmed if erratic readings appear on display prior 

to normal mode.

MODE