UEi DT150 Instruction Manual Download Page 2

C o n t rols and Indicators

1.

T h e r m o couple Po r t :

Polarized blades from miniature 

thermocouple probe plugs in here.

2.  

LCD Display:

Displays temperature and relative clock information.

3.  

Power Switch:

Powers instrument on and off.

4.  

Hold/Relative Switch:

Quick press freezes temperature data. 

Long press switches instrument to the relative-zero display mode.

5.  

Back Light:

Powers back light on and off.

6.  

K/J/T Thermocouple Select Switch:

Changes input reference 

for thermocouple ty p e .

7.

˚F/˚C Mode Select Switch:

Toggles display mode from degrees 

Celsius to degrees Fa h r e n h e i t .

8.  

Record Mode Select Switch:

Starts record mode (relative clock). 

Cycles display to indicate either the current temperature, the 
m aximum temperature, or the minimum temperature along with 
the hour and minute it was recorded.

Introduction

The DT 150 or DTO 150 is ideal for technicians working in HVAC/R 
maintenance, appliance repair, labora t o ry environmental monitoring,
process control, agriculture, and numerous other purposes.

Features include

• Measures from -328 to 2498˚F (-200 to 1370˚C)
• Record mode with relative clock
• Relative zero displays change in temperature
• Hold function
• Switchable ˚F or ˚C
• Back light

Safety Notes

Before using this meter, read all safety information carefully. In 
this manual the word 

"WARNING"

is used to indicate conditions 

or actions that may pose physical hazards to the user. The word 

"CAUTION"

is used to indicate conditions or actions that may 

damage this instrument.

WARNING!

Exceeding the specified limits of this meter is dangerous and can
expose the user to serious or possibly fatal injury.

• Read the safety precautions associated with the equipment being 

tested and seek assistance or advice when performing 
unfamiliar tasks.

• Place ONLY thermocouples (type K, J, or T) in the DT150

or DTO150 thermocouple ports.

• Make sure your DT150 or DTO150 is set for the proper 

thermocouple type you are using.

• Be sure the thermocouple you are using can withstand the 

temperature extreme it may be exposed to in your service task.

• Maintain your DT150 or DTO150 according to the schedule 

provided and calibrate it regularly.

International Symbols

DTO150-MAN    

P. 1

1

2

3

4

5

6

7

8

Summary of Contents for DT150

Page 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com DT150 DTO150 INSTRUCTION MANUAL ...

Page 2: ... purposes Features include Measures from 328 to 2498 F 200 to 1370 C Record mode with relative clock Relative zero displays change in temperature Hold function Switchable F or C Back light Safety Notes Before using this meter read all safety information carefully In this manual the word WARNING is used to indicate conditions or actions that may pose physical hazards to the user The word CAUTION is...

Page 3: ...res temperature using appropriate thermocouples Tables indicating the range and accuracy of this thermometer are provided in the specification section The type and quality of your thermocouple will limit the range and accuracy of this thermometer are provided in the Specification section The type and quality of your thermocouple will limit the range and accuracy of your measurement The LCD display...

Page 4: ...ents Battery Replacement Always use a fresh replacement battery of the specified size and type Immediately remove the old or weak battery from the meter and dispose of it in accordance with your local disposal regulations Old or defective batteries can leak chemicals that corrode electronic circuits WARNING To avoid electric shock be sure to turn off the meter s power before you remove or install ...

Page 5: ...ifts Thermocouple Ensure thermocouple type matches from known value type the displayed icon in a controlled Moisture Clean and dry thermocouple environment corrosion or blades Allow thermocouple plug debris on to air dry thermocouple blade Defective Confirm defect with known good thermocouple thermocouple Replace if required Relative clock will Thermocouple Record will not start without not start ...

Page 6: ...imited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required befo...

Reviews: