COMBUSTION ANALYSIS
T1
Insert flue probe into stack.
Adjust cone so the probe tip is
approximately at the center of
the stack.
Insert flue probe into combustion
input. Insert K-type temperature
probe into input T1.
Rotate rotary dial to O2/Eff for
O2/Eff Test Screen parameters.
Combu
stion Analy
zer
C160
CO
C
O2
T
EM
P
Status
v3
O2/Eff
CO/CO2
O2/Eff displays O2 (%), Gross
Efficiency, Flue Temperature.
Rotate rotary dial to CO/CO2 for
CO/CO2 Test Screen parameters.
STATUS
FLUE 1
AUX
FLUE 2
TEMP
Combu
stion Analy
zer
C161
CO
C
O2
T
EM
P
CO/CO2 displays CO (ppm),
Losses calculated, Excess Air
%, Make any adjustments need-
ed for proper combustion and
wait for changes in readings
(Repeat necessary).
BEFORE TESTING
Remove the rubber boot and red
drain plug. Allow the water to
drain out. Re-insert the rubber
plug and replace boot cover.
Remove protective rubber boot.
Remove water trap from analyzer.
Remove particle filter from
spigot and replace with new
one. Reattach trap and boot.
CHECKLIST
o
Clean particle filter
o
Water trap and probe line are
free of water
o
All hose and thermocouple
connections are properly
secured
o
Water trap is fitted correctly
o
Power on and zero
o
Flue gas probe is sampling
ambient FRESH air
NOTE
: If there is no hole, check with service and installation instructions of appliance for best testing
method or check with your local authority on best practice