background image

5

IMPORTANT SAFETY WARNINGS

 

 

WARNING

Read entire Safety Notes section regarding potential hazard and proper instructions before using this meter. In this 
manual the word “

WARNING

” is used to indicate conditions or actions that may pose physical hazards to the user.  

The word “

CAUTION

” is used to indicate conditions or actions that may damage this instrument. 

 

 

WARNING

To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can 
result in severe injury or death.

 

 

WARNING

•   Before each use, verify meter operation by measuring a known voltage or current.

•   Never use the meter on a circuit with voltages that exceed the category based rating of this meter. 

•   Do not use this meter during electrical storms or in wet weather.

•   Do not use the meter or test leads if they appear damaged. 

•   Ensure meter leads are fully seated and keep fingers away from the metal probe contact when making  

 

 

measurements. Always grip the leads behind the finger guards molded into the probe.

•   Do not open the meter to replace batteries while the probes are connected. 

•   Use caution when working with voltages above 60 DC or 25 AC RMS. Such voltages pose shock hazards.

•   To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. 

•   Unless measuring voltage or current, shut off and lockout power before measuring resistance or capacitance.

•   Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) to prevent shock  
 

and arc blast injury where hazardous live conductors are exposed.

•   Always turn off power to a circuit or assembly under test before cutting, unsoldering or breaking the current path.  
 

Even small amounts of current can be dangerous.

•   Always disconnect the live test lead before disconnecting the common test lead from the circuit.  

•   In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of  
 

victim’s apparent recovery. Electrical shock can cause unstable heart rhythms that may need medical attention.

•   If any of the following occur during testing, turn off the power source to the circuit being tested: arching, flame,  
 

smoke, extreme heat, smell of burning materials or discoloration or melting of components. 

 

 

WARNING

Higher voltages and currents require greater awareness of physical safety hazards. Before connecting the test leads; 
turn off power to the circuit under test, set meter to the desired function and range; connect the test leads to the meter 
first, then connect to the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power 
immediately and recheck all settings and connections. 

 

 

WARNING

This meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all 
recommended safety procedures that include proper lockout utilization and use of personal protective equipment that 
includes safety glasses, gloves and flame resistant clothing.

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for 053533508192

Page 1: ...μA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV F C REL Hz Hz W PF 0 10 20 30 40 50 60 LINK INSTRUCTION MANUAL ENGLISH DM525 True RMS 1000V Digital Multimeter w Temperature www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30 ...

Page 2: ...Capacitance 10 AC DC Microamps 6000μA 11 AC DC Milliamps 400mA 11 AC DC Amps 10A 12 Temperature C F 13 Low Z Low Impedance Filter 13 Frequency Duty Cycle 14 Relative REL Δ Mode 14 Wireless Capability 14 Watt Power Factor 15 Test Lead Notes 16 Battery Replacement 16 CONNECTING AND USING APP 17 19 FCC IC INFORMATION 19 WARRANTY 20 DISPOSAL 20 CLEANING 20 STORAGE 20 www calcert com sales calcert com ...

Page 3: ...CIFICATIONS Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 44 to 122 F 20 to 50 C Operating Humidity 75 max Operating Altitude 6561 ft 2000m Display 6 000 Back light Yes Over range OL is displayed Dimensions 7 27 x 3 5 x 2 17 Item Weight 18 8 oz Calibration Recommended annually CAT Rating CAT IV 600V CAT III 1000V Certifications cELTus UL 61010 1 2012 3rd CE EN 61010 1 2010 3rd IEC...

Page 4: ...o national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small amounts of current can be dangerous Always disconnect the live test lead before disconnecting the common test lead...

Page 5: ...e In the V μA mA or Amps function either select AC DC or change to manual ranging before pressing this button to enter MAX MIN mode Press repeatedly to alternate between Maximum and Minimum readings Press and hold to return to live readings G Select Button Press to select AC or DC or Auto Selection in the following functions Voltage μA mA Amps Press to select Hz Duty Cycle DCmV ACmV F C Ohm Contin...

Page 6: ...Indicator Maximum CAT Rating for fused input jacks Multifunction input port used for measuring AC or DC volts AC or DC mV Temperature Hertz Duty Cycle Watts Resistance Continuity Diode Capacitance AC or DC Amps AC or DC μA AC or DC mA Use CATIV test leads or higher L Recess for magnetic hanger M Test Lead Holders N Protective Rubber Boot O Battery Cover under protective rubber boot P Kick Stand Q ...

Page 7: ...8 dgts 2 0 20 dgts 0 1mV 600V Auto selection mode is not available DC MILLIVOLTS Ranges Accuracy Resolution Overload Protection 600 0mV 0 2 5 dgts 0 1mV 600V Auto selection mode is not available Note Meter automatically selects AC or DC WARNING Use CATIV rated Test leads or higher Do not attempt to measure more than 1000V AC DC Do not exceed 25 volts AC or 60 volts DC RMS at either the common or m...

Page 8: ...NK RANGE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo μA mAμA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV F C REL Hz Hz W PF 0 10 20 30 40 50 60 LINK Open Circuit Voltage Audible Threshold Overload Protection Approx 1 0V Approx 40Ω 600V Features MIN MAX HOLD SEL Buzzer sounds at less than 40Ω WARNING Do not measure resistance on a live circuit Continuity Lo...

Page 9: ...X HOLD SEL Ranges Accuracy Resolution Overload Protection 10 00nF 2 0 5 dgts 0 01nF 600V 100 0nF 0 1nF 1 000μF 2 5 5 dgts 0 001μF 10 00μF 0 01μF 100 0μF 0 1μF 9999μF 3 0 5 dgts 1μF Capacitance Open Diode Displays OL Both directions Reverse Bias Displays OL RANGE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo μA mAμA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV...

Page 10: ...um sensitivity 50μA DC auto selection mode only ACmA Ranges Accuracy Burden Voltage Resolution Overload Protection 45Hz to 500Hz 500Hz to 5kHz 60 00mA 1 0 5 dgts 1 5 10 dgts 2mV mA 0 01mA 600mA 1000V Fast Fuse 400 0mA 0 1mA Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Burden Voltage Resolution Overload Protection 60 00mA 0 8 5 dgts 2mV mA 0 01mA 600mA 1000V Fast Fuse 40...

Page 11: ...ad for 30 seconds max DC A Ranges Accuracy Burden Voltage Resolution Overload Protection 6 000A 1 0 5 dgts 0 02V A 0 001A 11A 1000V Fast fuse 10 00A 0 01A Minimum sensitivity 500mA auto selection mode only CAUTION 20A overload for 30 seconds max AC DC Amps 10A RANGE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo μA mAμA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM52...

Page 12: ...e scale between Fahrenheit and Celsius Features MIN MAX HOLD SEL F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolution Overload Protection 200 to 999 C 1 5 2 0 C 0 1 C 600V 1000 to 1350 C 1 5 2 0 C 1 C Temperature C F RANGE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo μA mAμA A mA 10A MAX FUSED 400mA ...

Page 13: ...lution Overload Protection 99 99Hz to 999 9kHz 0 05 3 dgts 0 01Hz to 0 1kHz 600V Duty Cycle Ranges Accuracy Overload Protection 1 0 to 99 0 0 1 3 dgts 0 2 per kHz 600V Frequency Duty Cycle RANGE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo μA mAμA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV F C REL Hz Hz W PF 0 10 20 30 40 50 60 LINK Low Z μA A mA mV F C Hz...

Page 14: ...rrent clamp transformers The meter automatically selects the range which allows for the highest possible resolution of the applied quantities NOTE If the meter activates a measuring range which is too high during automatic measuring range selection this may be due to peak value monitoring Check the crest factor of the respective signal in Volts AC or DC or Amps AC or DC Significance of the Power Fa...

Page 15: ...s such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the meter s specific CAT rating Observe the maximum category protection indicated on the meter the test leads are plugged into Battery Replacement When the batteries are too low for safe operation the Low Battery indicator will display 4mm...

Page 16: ...er to activate wireless BT Open App Meter will connect automatically Menu Press to connect disconnect and access settings Settings General settings adjust button sound vibrate and refresh rate Recording settings Continuous reading Number of samples Sampling interval CONNECTING AND USING THE APP Record Press to start stop The number of samples will show in real time www calcert com sales calcert co...

Page 17: ...yy mm dd hh mm ss Functions are noted underneath respectively AMP AMP TOP BOTTOM Display Press button for summary Press button for sample data Press button to export data via email in csv png or jpg format www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30 ...

Page 18: ...rference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receivin...

Page 19: ...ase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol indicates that equipment and its accessories shall be subject to separ...

Reviews: