EN-10
EN-11
Operating the device
Operating the device
• Repeat these steps to enter the day (Figure 3) and
the hours and the minutes (Figure 4).
played, and press the MEMO button to reduce the
value displayed. Set the correct month and con-
firm the entry by pressing the START button.
• You are now able to set the temperature unit (Fig-
ure 5). Press the MODE button to switch between
°C (Celsius) and °F (Fahrenheit). Set the required
temperature unit and confirm the entry by press-
ing the START button.
• The basic settings have now been configured. The
device switches off.
If no button is pressed for approximately 30 seconds
while configuring the basic settings, the device switches off automat-
ically. However, any entries that have already been confirmed will still
be saved.
After changing the battery, you must enter the date and time again.
With the device switched off, press the MODE button. The current
status of the beep function is shown on the display:
Beep switched on
Beep switched off
Figure 4
Figure 5
Switching the beep on/off
Taking measured values directly from the middle ear (eardrum) en-
sures the most accurate temperature measurement. Measurements
taken on the surrounding tissue of the ear canal will result in lower
measured values and can lead to an incorrect diagnosis of a fever.
For this reason, it is very important to position the thermometer in the
ear correctly. It is essential to follow the instructions on positioning the
thermometer in the ear in the chapter “Measuring the temperature“
on page 12.
Always measure the temperature in the same ear, as the temperature
values may vary from ear to ear.
In the following situations, you should take three consecutive tem-
perature measurements in the same ear and take the highest result as
the measured value:
Rest for at least 5 minutes before taking the measurement.
– In children under three years of age with a vulnerable immune sys-
tem where the presence or absence of fever may be critical.
– If you are familiarising yourself with the device and are practis-
ing how to use the infrared ear thermometer correctly until you
achieve consistent measured values.
Avoiding inaccurate measurements
Switch off the device by pressing the on/off button or wait until the
device switches off automatically after approximately ten seconds.
You can now use the MODE button to switch the beep function on
or off.
Make sure that the measuring sensor is always clean. A dirty or
clogged measuring sensor can lead to incorrect measurements.
– If you feel the measured values are unusually low.