background image

General characteristics

- Electronic protection against short-circuits in output.

- Power supply suspend.

- Excess temperature (110 C in the power radiator) detector. In the event of overheating caused by a
ventilation obstruction, a safety device will be triggered. When temperature conditions revert to
normal this devise switches off automatically.

- Digital keypad for microphone volume, auxiliary volume, treble and bass.

- Control device for attenuator with maximum level restoration (three wires) incorporated.

- Input 1: balanced microphone, phantom power supply with remote control input (TM1).

- Input 2: auxiliary with remote control input (TM2).

- Signal input/output connection for audio processors (EG-31, etc.)

- Signal output for other amplifiers, with remote-controlled device for attenuators.

- On/off

- Modulation

- Luminous digital display

- 230 VAC at 50/60 Hz

. Antilarsen module.

. Handle / bracket for mounting on 19” rack

. Signal lead

. EG-31 insertion cable.

The

amplifier has a plug-in connection jumper which allows the user to change the

sensitivity of the auxiliary input from 770 mV to 250 mV (see graphic).

Indicators:

Power supply:

Optional accessories:

- WX-19

- WX-3

- CA-01

- CA-32

NOTE:

AX-459

AX-459

15

4

610.105A

Summary of Contents for AX-459

Page 1: ...mentation 12 VDC sensitivity 770 mV 250 mV impedance 47 K Signal output level 800 mV impedance 600 Insertion output 400 mV 600 input 400 mV 4700 4 8 Insertion connector for external signal processors 8 bits microprocessor ON MOD OFF ON Digital F MIC AUX 4 3 2 1 5 6 7 8 AX 459 15 1 610 105A POWER AMPLIFIER DIGITAL TECHNICAL CHARACTERISTICS C LUIS I 88 3ª planta 28031 MADRID ESPAÑA Tel 34 91 311 60 ...

Page 2: ...r Auxiliary digital control 6 7 8 9 Front controls 10 16 17 18 11 12 13 14 15 Data connector not available 2 Speaker priority line terminal 5 Speaker line terminals 4 AC input and fuse Reset button 3 Miicrophone input Auxiliary input Insertion input output 1 0 dBm signal output 16 11 15 10 17 12 18 13 14 Rear connections ON MOD OFF ON Digital F MIC AUX 4 3 2 1 5 6 7 8 AX 459 15 2 610 105A ...

Page 3: ...ess the load impedance menu and make the adjustments automatically or else select the right value manually in each case 4 8 70 V line 11 or 100 V line 22 This function is highly useful since it makes it possible to record in the non volatile memory any adjustments made for different utilisation conditions thereby optimising the public address system in applications in fluctuating acoustic conditio...

Page 4: ...orporated Input 1 balanced microphone phantom power supply with remote control input TM1 Input 2 auxiliary with remote control input TM2 Signal input output connection for audio processors EG 31 etc Signal output for other amplifiers with remote controlled device for attenuators On off Modulation Luminous digital display 230 VAC at 50 60 Hz Antilarsen module Handle bracket for mounting on 19 rack ...

Page 5: ...aken to comply with any applicable safety standards Do not block the front and rear air vents in order to make sure the unit will work properly Start up the unit and make any adjustments you require Impedance Volume microphone Volume auxiliary Treble Bass Programming 1 to 8 Operating mode standard or programmed selection The unit is now ready to operate Volume 7 0 Treble 0 Bass 0 Volume 7 0 Treble...

Page 6: ...Remove the screws A from the rear subchassis Move the subchassis to expose the signal input output circuit Connect the jumper as required Replace the rear subchassis and the 4 screws A Checked that all the connectors fit properly into their respective housings Replace the top cover of the unit AX 459 15 6 610 105A ...

Page 7: ...etc ATTENUATOR 3 wires maximum level restoration EG 31 EQUALIZER PX 9 PRE AMPLIFIER 230 VAC MIC AUX BASIC CONNECTION SYSTEM WX 19 antilarsen module AUXILIARY AMPLIFIER CA 01 CA 32 CA 01 Connection diagram OPTIONAL ELEMENTS AX 459 15 7 610 105A ...

Page 8: ...X 3 handle bracket mounting rack 1 2 WX 19 3 WX 19 4 5 D 6 Remove the top cover of the unit Remove the bracket for the module Assemble the module in the aforementioned bracket using the screws supplied Fit the 6 lead connection as shown Extract jumper No special adjustment is needed Fix the bracket in position The unit is ready to operate AX 459 15 8 610 105A ...

Page 9: ...AC 12 VDC 5 VDC 15 VDC 450 W RMS 0 dBm OUTPUT INSERTION MIC AUX TM1 TM2 TM DIGITAL CONTROL CONTROL DIGITAL SIGNAL 92 VDC AUX MIC Th 65 C P _ 230 VAC MATCHING MICROPROCESSOR Block diagram AX 459 15 9 610 105A ...

Page 10: ...memory of the standard operation mode for the unit and restore default values factory settings Record programmes Copy content from one programme to another Edit correct an existing programme Select the unit s operating mode mode 1 mode 2 Return to the user menu Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Press the F key and then while you hold down the aforementioned key press key...

Page 11: ... 6 2 1 7 8 MIN MIN MIN MAX MAX MAX AUX PUSH SHORT TIME 2 MANUAL ADJUSTMENT CURRENT IMPEDANCE VALUE NEW IMPEDANCE VALUE INSTALLER MENU Z 4W Z 8W L 70V L 100V F F F 1 2 3 F 4 F 5 Fig 3 MANUAL IMPEDANCE SELECTION INSTALLER MENU 3 AUTOMATIC ADJUSTMENT CURRENT IMPEDANCE VALUE ADJUSTED VALUE 4 8 70V 100V W W F 1 F 5 Fig 4 AUTOMATIC IMPEDANCE MATCHING NOTE During automatic impedance adjustment one or sev...

Page 12: ...ME E g edit programme 7 5 PRESET PROGRAMME MENU CALL UP PROGRAMME TO SELECT RECOVER SETTINGS RECORDED IN PROGRAMME 7 F 2 7 F 5 4 5 6 2 1 7 8 MIN MIN MIN MAX MAX MAX AUX 5 6 4 3 7 8 MIN MIN MIN MAX MAX MAX CORRECT VALUES VOLUME TREBLE BASS MICROPHONE INPUT E1 CORRECT VALUES VOLUME TREBLE BASS AUXILIARY INPUT E2 MIC INSTALLER MENU ACTIVE INPUT E1 or E2 SELECT MICROPHONE INPUT E1 ON SELECT AUXILIARY ...

Page 13: ...h and the heat protector has been triggered The microprocessor has detected some kind of anomaly in the power supply of the power circuit and has switched it off Thus if the message appears check whether the passage of air front and rear is blocked and put the problem right Switch off the amplifier allow it to cool and then switch it back on again Otherwise switch off the unit and call technical a...

Page 14: ...ration with remote controlled message priority INDICATE VOLUME VALUE ISSUE PRIORITY MESSAGE REMOTE CONTROLLED TM1 E1 MESSAGE PRIORITY REMOTE CONTROLLED TM2 E2 MESSAGE PRIORITY INDICATE VOLUME VALUE ISSUE PRIORITY MESSAGE OperatingtheAX 459withremotecontrolsTM1andTM2 Regardlessofwhichactiveinputisselected E1orE2 whenTM1is pulled E1 becomes the active input with its corresponding volume treble and b...

Page 15: ...OTE CONTROLLED TM2 E2 MESSAGE PRIORITY CURRENT PROGRAMME ISSUE PRIORITY MESSAGE OperatingtheAX 459withremotecontrolsTM1andTM2 Regardlessofwhichactiveinputisselected E1orE2 whenTM1is pulled E1 becomes the active input with its corresponding volume treble and bass settings At the same time the attenuator control deviceisactivatedwith3 wiremessagepriority terminalP Once remote control TM1 is off the ...