Office: 972.556.0916 Fax: 972.910.8384
SWIFT offers the PSD1 wall plug for users who wish to leave their LSSM turned on for long periods of time.
This is
NOT
a charger, but rather powers the unit from a wall outlet.
PSD1 BATTERY BYPASS
SPECIFICATIONS
Wavelength
Output Power
Output Stability
Spectral Width
Optical Interface
Tone Output
Power
Battery
Operating Temperature
Storage Temperature
Dimensions
Weight
DUAL SINGLEMODE LASER SOURCE
1310nm & 1550nm
-5.0dBm
±0.05dB (1 hour)
±0.03dB long-term (15 min warm-up)
5nm/5nm
SC/FC/ST/LC interchangeable
2kHz
Push button toggle/auto-off
CR2
-10º to +50ºC
-30º to +60ºC
6.1” x 0.94” x 0.75” (15.5 x 2.83 x 1.9cm)
3oz. (85.4g)
3330 Earhart Drive, Suite 208
|
Carrollton, TX 75006
|
Office: 972.556.0916
|
Fax: 972.910.8384
PAGE 5
LSSM
CK-01
Bag, 9x8x3 zippered
Swabs, package of 25
AquaKleen cleaner, 2 fl oz bottle
FiberKleen wipes, pk of 50 wipes
Brush
Screwdriver
Tweezers
Illuminated jeweler’s loupe
Instruction sheet
Zipper pull
Sharpie, medium point
CK-02
Bag, 9x8x3 zippered
Swabs, package of 25
AquaKleen cleaner, 2 fl oz bottle
FiberKleen wipes, pk of 50 wipes
IBC-SC
IBC-LC
Optipop-R
Instruction sheet
Zipper pull