NEO-D9S - Integration manual
All message output is additionally subject to the protocol configuration of the
communication interfaces. Messages of a given protocol will not be output until the protocol
is enabled for output on the interface (see
Communication interface configuration
3.1.5 L-band service selection
Any particular service provider will have several requirements that need to be configured before the
receiver will provide the relevant service provider data:
• Service provider service ID
• Service provider frequency based on geographical location
• Service provider data rate
The service provider will provide the information on the frequency required per geographical
location.
All relevant configurations are done via the CFG-PMP message.
The main settings are shown below:
• CFG-PMP-SERVICE_ID - Example, 50821
• CFG-PMP-CENTER_FREQUENCY - Can be set from 1525000000 to 1559000000 Hz
• CFG-PMP-DATA_RATE - Can be set from 600 bps to 4800 bps
There may be additional settings required that can be configured from the information supplied by
the service provider.
The receiver will output raw L-band correction data when a service provider satellite data frame is
received. This will be output in the UBX-RXM-PMP message. This message is not output at a fixed
rate.
If no selected service provider data frame is detected, no UBX-RXM-PMP message is sent. The
output rate of the UBX-RXM-PMP message depends on the data rate of the satellite data stream
(600 bps - 4800 bps). The validity of the data frame must be verified by the host software. For frame
verification, quality indicators included in this message can be used.
For more information see the Configuration Interface section in the applicable Interface description
[
].
Figure 2: L-band SESTB-28A data frame
3.1.6 Power management
u-blox D9 correction data receiver supports two different externally controlled power modes.
• External cycling of the receiver main power supply with the receiver in continuous mode when
powered
• Instruct the receiver to turn on/off into software back-up mode (with main power still applied)
via the UBX-RXM-PMREQ message