EVK-JODY-W3 - User guide
UBX-20030840 - R02
Specifications
Page 8 of 29
2
Specifications
This section includes the different operating parameters for the EVK-JODY-W3.
2.1
Operating conditions
Table 3 describes the absolute range for key EVK operating parameters.
Symbol
Parameter
Min.
Typ
Max.
Units
3V3
Power supply voltage
3.14
3.3
3.46
V
VIO
I/O supply voltage 1.8 V
1.71
1.8
1.89
V
I/O supply voltage 3.3 V
3.14
3.3
3.46
V
1V8
Analog power supply voltage 1.8 V
1.71
1.8
1.89
V
T
A
Ambient operating temperature
-40
-
+85
*
ºC
Ripple Noise Peak-to-peak voltage ripple on all supply lines.
-
-
30
mV
Table 3: EVK-JODY-W3 operating conditions
☞
The signal voltage for the SDIO interface of the JODY-W3 series module is powered from the
1V8
supply. A level shifter is required to operate the module in Default Speed and High-Speed
modes at 3.3 V signal voltage [3]. For further information contact your local u-blox support