EVK-G45 - User Guide
UBX-18058360 - R01
Starting up
Page 8 of 21
1.5
Connectors
Function
Description
Name
Board
9 - 18 V power input Connector for the AC / DC power adapter of the EVK
AC: 100-240 V, 0.8 A, 50-60 Hz / DC: +12 V, 2.5 A
IEC 60417-5172
Class II equipment
J400
EVB
SIM card holder
SIM card holder
J300
EVB
Cellular antenna
SMA connector for the cellular module antenna
J0501
ADP-G450
Cellular USB
(UART AUX)
Micro USB 2.0 type B connector for the cellular module UART AUX interface
converted as USB interface
J0600
ADP-G450
Cellular USB
(UART/UART FT)
Mini USB 2.0 type B connector for the cellular module UART and UART FT
interfaces converted as USB interface
J501
EVB
Cellular RS232
(UART)
DB9 connector for the cellular module UART interface converted as an RS232
interface
J500
EVB
DIL B2B headers
Dual in-line board-to-board connectors for the cellular module interfaces
J0403,
J0404
ADP-G450
Header connector
Header connector for the cellular module UART AUX interface
J0601
ADP-G450
Cellular headset
Audio headset jack connector for the cellular module audio interface
J303
EVB
GNSS antenna
SMA connector for the GNSS module antenna (GNSS Antenna)
J208
ADP-GNSS
GNSS USB
Mini USB connector for the GNSS module USB interface
J102
ADP-GNSS
GNSS backup
battery
Backup battery socket for the GNSS module (under the GNSS adapter board) BT200
EVB
GND
Ground terminals for the probe reference
J402, J403
J405, J406
EVB
Table 3: Description of EVK-G45 connectors
⚠
CAUTION! IN THE UNLIKELY EVENT OF A FAILURE IN THE INTERNAL PROTECTION CIRCUITRY,
THERE IS A RISK OF AN EXPLOSION WHEN CHARGING A FULLY OR PARTIALLY DISCHARGED
BATTERY. REPLACE THE BATTERY WHEN IT NO LONGER HAS A SUFFICIENT CHARGE FOR
UNIT OPERATION. CONTROL THE BATTERY BEFORE USE IF THE DEVICE HAS NOT BEEN USED
FOR AN EXTENDED PERIOD OF TIME.
⚠
CAUTION! RISK OF EXPLOSION IF BATTERY IS REPLACED WITH AN INCORRECT TYPE. DISPOSE
OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS!