PON 

              ONU 

Battery Operating 

 

Charging:

 When you connect AC power and Battery at the same time, it is charged 

automatically. In case of a new battery, you cannot make sure that the voltage value is 
going up with your eyes because it is charged slowly. 

 

Discharging:

 When AC power stops, it is discharged automatically and the battery 

replaces AC power. 

 

Operating:

 The battery normally operates for 6 hours in case of using every port. When 

the battery starts charging via AC power again, it will be fully charged after 5 hours.   

 

 

 
 
 

<Figure 10> Connecting AC power cable, DC power lines, and Grounding Cable.   

 

 

Note  The specification of power to be supplied to AC power supply of E3208E is 

as follows. 

-

 

Voltage : AC 100V ~ AC 240V 

-

 

Power Consumption : max 16.9 Watt 

-

 

Input Frequency : 50/60Hz 

 

Warning  Because the battery using to E3208E ONU is 12V (4.5AH) VRLA 

battery, it may have the danger of gas-leak and of explosion on the 
overcharge or the over-discharge.   
E3208E cut off the current at less than 10.5V battery voltage and also 
cut off the current at more than 13.5V battery voltage to charge. 
(Charging current max 800mA) 
 
The power supply that does not meet the above specifications can 
cause damage to the product or a fire. 

 

Connecting Console Terminal 

E3208E can be configured or monitored by connecting a console port to the product directly. 

The user can use the console cable that came with the product to connect the product and 

the console terminal. Connect the RJ-45 connector of the console cable to the console port 

of the product and the DB-9 connector (the other side of the cable) to the console terminal. 

The terminal device used as the console terminal of E3208E should be set according to the 

following communication configuration in order to communicate with E3208E normally. 

  Baud Rate: 9600 bps 

  Data Bit: 8 bit 

  Stop Bit: 1 bit 

  Parity Bit: None 

  Flow Control: None 

 

E3208E Installation Guide 

25

Summary of Contents for E3208E

Page 1: ...PON ONU E3208E Installation Guide...

Page 2: ...E3208E Installation Guide II ubiQuoss Inc 24F Millennium B D 467 12 Dogok Dong Gangnam Gu Seoul 135 700 Korea TEL 82 70 8666 5000 FAX 82 2 2190 3201 E mail oversea team ubiQuoss com www ubiQuoss com...

Page 3: ...t safely The user manual command manual and configuration manual that come with this installation guide covers the functions usage and settings more in detail The audience of this installation guide i...

Page 4: ...orrect product operation can occur and provides the proper actions to take in the situation Warning Describes the situation that product damage and the user s injury can occur and provides the proper...

Page 5: ...understand the notes in this chapter before installing the product to prevent any problem from occurring during the product installation Chapter 3 Installation This chapter describes how to install E3...

Page 6: ...uirements for Installation 19 Complying with operation environment condition 19 Preventing Static Electricity 19 Requirements for handling Power 20 Grounding 21 Lightening 21 Preventing Overheating 21...

Page 7: ...PON ONU Specification 32 Appendix B Cable Spec 33 Ethernet cable 34 Optical cable 34 Console cable 35 E3208E Installation Guide VII...

Page 8: ...st of Figure and Table Table 1 Console port Specification 14 Table 2 System status LED 15 Table 3 Port status LED 15 Table 4 List of Package Items 22 Table 5 Specification 32 Table 6 Configuration of...

Page 9: ...ure 3 LEDs and Console Port 14 Figure 4 Console Port Pin numbers 14 Figure 5 System Status LED 15 Figure 6 Fast Ethernet 8 Ports 15 Figure 7 E3208E ONU Real Panel 16 Figure 8 RST button 16 Figure 9 E3...

Page 10: ......

Page 11: ...ion This chapter describes the types and features of E3208E and explains the name and function of each part This chapter consists of the following sections Features of Product Appearance of Product E3...

Page 12: ...performance switching service to subscribers It can be also deployed economically because it is based on 100Mbps downlink speed as FE and an uplink port as GE PON E3208E is the best solution for mediu...

Page 13: ...ort RJ 45 Type Fast Ethernet 10 100B T 8 ports E PON Up link and LEDs for system status Up Link Slot port Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not...

Page 14: ...n the console port and a console terminal comes with the product A PC workstation or VT 100 with terminal emulator program installed can be used as a console terminal The following table show the cons...

Page 15: ...k down EPON Link up Rx sensitivity 26dBm 24dBm PWR Green Off Power Normal Power Off DATA Green Blink Off EPON Data Tx Rx EPON no Data Fast Ethernet 8 Port E3208E has port status LEDs that indicates th...

Page 16: ...rear side Figure 7 E3208E ONU Real Panel RST Button Figure 8 RST button E3208E has a reset button on the side of the system so that the user can manually reboot the system by pressing the RESET button...

Page 17: ...PON ONU Side View Air Flow The vent hole is the part required for air intake or outtake to prevent the Switch from getting overheated Figure 9 E3208E ONU Right Left Side E3208E Installation Guide 17...

Page 18: ...talling and using the product The user should fully understand the notes in this chapter before installing the product to prevent any problem from occurring during the product installation This chapte...

Page 19: ...magnetic wave can cause a problem to the product operation so avoid the location where an electro magnetic wave is generated Install the product in the location that the user can easily access and con...

Page 20: ...is not tight because it can cause an electric shock and a fire Always check the working place for the possibility of any danger the wet floor non grounded power extension cable the floor with no grou...

Page 21: ...the temperature of other products or unsmooth air circulation Do not block the cooling fan and vents on the top bottom of the product because they play an important role of cooling down the system te...

Page 22: ...nts of Package E3208E Switch package contains the following components Table 4 List of Package Items Components Qty Use Main Body 1 set E3208E ONU Main Body Manual CD 1 ea A manual CD that contains in...

Page 23: ...tall E3208E Switch on a rack and connect each port of the switch This chapter consists of the following sections Selecting Installation Place Connecting Power Connecting Console Terminal Connecting EP...

Page 24: ...ed to any injury put the device and tools away from the location that people often visit Install the product in the location that the user can easily access and connect a cable to the product easily E...

Page 25: ...may have the danger of gas leak and of explosion on the overcharge or the over discharge E3208E cut off the current at less than 10 5V battery voltage and also cut off the current at more than 13 5V...

Page 26: ...ber of bits per sec in the console terminal In case that the characters on the console terminal screen are broken or that no character is displayed check the number of bits per sec set in the terminal...

Page 27: ...wer switch connected to the power supply to ON direction to turn on the power of the equipment Then check if the LEDs on the front panel of the equipment work as follows Press the power switch to ON d...

Page 28: ...s in case that console terminal connects the system click Enter key Then you can see login massage Note For configuration of equipment after logging in to the CLI please refer to the user manual of E5...

Page 29: ...of the problems occurred to the equipment can be easily checked and solved by the user If the equipment does not work properly please check if the problem can be solved referring to the description gi...

Page 30: ...Problem 3 Nothing appears on the console terminal display or the characters are crashed The console cable is wrong or the communication configuration of the console terminal is wrong Solution 1 Check...

Page 31: ...properly or wrong cables are used or the other equipment is not working properly Solution 1 Check if the cable connector is properly connected to the SFP port 2 The connector of optic cable can be eas...

Page 32: ...R System power status LINE EPON Link up Green EPON Link down Red EPON Link up Low signal Rx sensitivity 26dBm 24dBm Orange Port status LED DATA EPON Data Transmission Status Green BLINK LNK ACT Link S...

Page 33: ...wing sections Ethernet cable Optic cable Console cable Note The standards of various Ethernet ports on the front panel of E3208E are as follows Interface Standard Cable Type Max Distance IEEE Specific...

Page 34: ...Twisted pair cable depending on the speed of the equipments to be connected 10B T Category 3 5 5E 6 100B TX Category 5 5E 6 Optical cable EPON Up Link port uses simplex SC fiber optic cable When the c...

Page 35: ...able below describes the types of the signals transmitted from each pin of the connectors on both sides of a console cable Table 6 Configuration of terminal mode Pin Number Console port Pin Number Con...

Reviews: