background image

Important Warning Regarding Emergency Calls

NOTE THAT THE LIMITATIONS SET FORTH BELOW ARE APPLICABLE TO 
ALL EMERGENCY CALLS, FUNCTIONS AND SERVICES, INCLUDING 911, 
ENHANCED 911 AND 112 CALLS (COLLECTIVELY, “EMERGENCY SERVICES”). 
1.  You should be aware that:

a.  Emergency Services may not connect to the Public Service 

Answering Point (“PSAP”), or may ring to the administrative line 
of the PSAP, which may not be staffed after hours, or by trained 
emergency operators.

b.  VoIP customers may need to provide location or other information 

to their VoIP providers, and update this information if they change 
locations, for their Emergency Services to function properly.

c.  VoIP service may not work during a power outage, or when 

the Internet connection fails or becomes overloaded. Consider 
installing a backup power supply, maintaining a traditional phone 
line or having a wireless phone as a backup.

d.  VoIP service will not function if the telephone equipment or other 

equipment necessary to place calls is not correctly configured.

e.  Emergency Services may correctly connect to the PSAP, but may 

not transmit the user’s phone number and/or location information.

f. 

VoIP calls may not be capable of being received and/or processed 
by an emergency call center due to the center’s technical 
limitations.

g.  VoIP calls may be affected by other factors or force majeure events, 

such as the quality of the broadband connection and network 
congestion.

2.  You should:

a.  Provide your accurate physical address to your interconnected 

VoIP service provider to ensure that emergency services can 
quickly be dispatched to your location.

b.  Be familiar with your VoIP service provider’s procedures for 

updating your address, and promptly update address information 
in the event of a change.

c.  Have a clear understanding of any limitations of your Emergency 

Services.

d.  Inform children, babysitters and visitors about your VoIP service 

and its Emergency Services limitations.

3.  By installing the phone, you are affirmatively acknowledging that (i) 

you have read and understood this Warning, (ii) you understand that 
you may not be able to contact emergency services by dialing or using 
any Emergency Service, and (iii) you understand that you must inform 
users of the phone that they may not be able to contact emergency 
services by dialing or using any Emergency Service. 

4. 

IN NO EVENT SHALL UBIQUITI NETWORKS, ITS AFFILIATES, 
OFFICERS, DIRECTORS, EMPLOYEES, REPRESENTATIVES, AGENTS 
OR ANY OTHER THIRD‑PARTY PROVIDER OR VENDOR WHO MAY 
FURNISH SERVICES OR PRODUCTS TO YOU IN CONNECTION WITH 
THE VOIP SERVICES OR THE EQUIPMENT BE HELD LIABLE FOR 
ANY CLAIM, DAMAGE, OR LOSS WHATSOEVER ARISING FROM OR 
RELATING TO EMERGENCY SERVICES, AND YOU HEREBY WAIVE 
ANY AND ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING 
THEREFROM OR RELATING THERETO.

Summary of Contents for UT-Phone-Touch

Page 1: ...VoIP Phone with 5 HD LCD and Touch Model UVP Touch TALK UT Phone Touch ...

Page 2: ...ckage Contents UniFi VoIP Phone Touch Installation Requirements UniFi Switch or PoE 802 3at compliant switch Third Party SIP PBX Provider Hardware Overview Front Camera LED Touchscreen Volume Keypad TALK ...

Page 3: ...ad Touch to display the numeric keypad Volume Use the volume arrows to adjust audio levels LED The LED will illuminate when the device is first connected to a 48V power source Once the phone has started up the LED will turn off IMPORTANT The LED will flash when a firmware update is occurring Do not disconnect power Ethernet from the device during this time Back Ports PoE LAN PC PoE LAN PC ...

Page 4: ...the same network as the UniFi Security Gateway VOIP port PC The Ethernet port labeled PC is used for bridging WARNING Do not connect a powered Ethernet connection to the port labeled PC Side Ports USB C Port The USB C port can be used to charge a device Headset Jack 3 5 mm jack for optional wired stereo and microphone headsets ...

Page 5: ...Handset Mute button Mute Press the Mute button to mute the microphone on the handset Hardware Installation 1 1G ...

Page 6: ...2 PoE LAN PC Configuration Enter the SIP server address username and password Enter server details and credentials Manual Setup Continue BACK SIP SERVER USERNAME PASSWORD ...

Page 7: ...Making a Call Lift the handset to make a call and the keypad will appear Use the Delete button to correct any mistakes Press the Call button to make a call Delete Contacts Call Favorites Recents ...

Page 8: ...l Connection Status Displays Dialing or the total elapsed time of the currently connected call Mute Mute the microphone so that audio is not broadcast Hold Place the caller on hold Hold music will be played Add Call Press to add another call for a group conversation Transfer Elect to transfer a call blind directly or attended with an introduction from you Keypad Display the numeric keypad ...

Page 9: ... Pnom 2W Pmax 3W SPL 80dB 1W 0 5m Hands Free Microphone Dual Omnidirectional MEMS Microphones SNR 64 dB Sensitivity 26dBFS Digital Microphone Connectivity 2 10 100 1000 Ethernet Ports 1 Type C Port charging only Bluetooth 4 2 Wi Fi 2 4G b g n BW 20 40 Wi Fi 5G a n ac BW 20 40 80 Slave DFS Headset Support 3 5 mm Audio Jack Processor Octa Core CPU 8x ARM Cortex A53 1 8 GHz Memory eMCP 32 GB eMMC 16 ...

Page 10: ...alls may be affected by other factors or force majeure events such as the quality of the broadband connection and network congestion 2 You should a Provide your accurate physical address to your interconnected VoIP service provider to ensure that emergency services can quickly be dispatched to your location b Be familiar with your VoIP service provider s procedures for updating your address and pr...

Page 11: ...ed with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a The equipment requires the use of the ground wire as a part of the safety certification modification or misuse can provide a shock hazard that can result in serious injury or death b Contact a qualified electrician or the manufacturer if there are questions about the insta...

Page 12: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tec...

Page 13: ...5A UVPT a été approuvée par Industrie Canada RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute per...

Page 14: ...ed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol ...

Page 15: ...que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre anci...

Page 16: ...innitab et antud UVP Touch seade on vastavus olulistele nõuetele ja teistele asjakohastele sätetele direktiivide 2014 53 EL ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www ubnt com compliance Suomi Finnish Täten UBIQUITI NETWORKS vakuuttaa että tämä UVP Touch laite on yhdenmukainen olennaisten vaatimusten ja muiden sitä koskevien direktiivien 2014 53 EU EU ...

Page 17: ...rtuguese UBIQUITI NETWORKS declara que este dispositivo UVP Touch está conforme com os requisitos essenciais e outras disposições das Directivas 2014 53 UE O texto integral da declaração de conformidade está disponível no seguinte endereço de Internet www ubnt com compliance Română Romanian Prin prezenta UBIQUITI NETWORKS declară că acest dispozitiv UVP Touch este în conformitate cu cerințele esen...

Page 18: ...biquiti beam logo and UniFi are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries Google Android Google Play and other marks are trademarks of Google Inc All other trademarks are the property of their respective owners RR022719 w w w u b n t c o m ...

Reviews: