background image

4.  Align the Arrow on the top edge of the UAP‑XG with the 

Arrow on the Mounting Plate.

Lock Tab

Arrow

Arrow

5.  Rotate the UAP‑XG clockwise until the tabs lock into place 

and the Lock Tab engages.

Summary of Contents for UniFi XG UAP-XG

Page 1: ...Quad Radio 802 11ac Wave 2 Access Point with Dedicated Security Model UAP XG ...

Page 2: ...unts Qty 2 T Bar Screws Qty 2 Allen Wrench Wall Screws Qty 4 Screw Anchors Qty 4 Quad Radio 802 11ac Wave 2 Access Point with Dedicated Security Model UAP XG Release Tool Cable Feed Plug Gigabit PoE 50V 1 2A Power Cord Quick Start Guide Included only with the single pack of the UAP XG TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cable and earth grounding m...

Page 3: ... Mounting location should be at least 60 cm 2 ft from the edge of the eave or ceiling Cable feed opening must be directed away from the open environment Cable feed must be pointed downwards when wall mounted Shielded Category 6 or above cabling should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE System Requirements Linux Mac OS X or Mic...

Page 4: ... c9m A W l c9m A 2 82 322 ধ32V 30 Mbps 40 Mbps 50 Mbps 20 Mbps 10 Mbps 0 Mbps 24 hrs 12 hrs Now 3 2 3 38 ধ 6 Throughput Portland SDN SW 24A SW 8A SW 8B SW 24E SW 24D 56 9 35 6 34 28 24 39 ধ 9 USG PRO 4 DHCP Server US 16 XG UniFi Hybrid Cloud Install Good Fair Poor Great Network Switches 12 Gateway ধ A ধ32 18 Internet Capacity 43 Clients 412 Guests 113 IoT 45 Everything is great My Dashboard Edit W...

Page 5: ...e upgrade is taking place Blue Indicates the device has been successfully adopted by a network and is working properly Quickly Flashing Blue This is used to locate an AP When you click Locate in the UniFi Controller software the AP will flash It will also display the location of the AP on the map Steady Blue with Occasional Flashing Indicates the device is in an isolated state all WLANs are brough...

Page 6: ...or more than five seconds 1 GbE The 1 GbE port is a 10 100 1000 Ethernet port used for bridging It can also be used to connect the power 10 GbE The 10 GbE port is a 1 10 Gbps Ethernet port used to connect the power and should be connected to the LAN and DHCP server For 10 Gbps operation connect the UAP XG to an 802 3bt POE switch Note The UAP XG can also be powered using a 50V 1 2A Gigabit PoE ada...

Page 7: ...e with the UAP AC PRO mounting hardware so you only need to remove the UAP AC PRO and replace it with the UAP XG To begin the upgrade 1 Insert the Release Tool into the UAP AC PRO Security Slot to disengage the lock Then turn the UAP AC PRO counterclockwise and lift it off of the mounting bracket Security Slot UAP AC PRO Wall Mount Installation 2 Unplug the Ethernet cable from the Main port 3 Go t...

Page 8: ...brackets used for previous UniFi AP models Wall Mount 1 Position the Mounting Plate at the desired location on the wall with the Arrow pointing up 2 Mark the four mounting holes marked A and use an 8 mm drill bit to drill the holes If your Ethernet cable feeds through the wall cut or drill a hole approximately 18 mm in diameter Then feed the CAT6A cable through the hole Arrow Optional 18 mm Hole f...

Page 9: ... the Mounting Plate to the wall by inserting the Wall Screws into the anchors 4 Go to the Connecting Ethernet section and then return to step 5 5 Align the Arrow on the top edge of the UAP XG with the Arrow on the Mounting Plate Arrow Lock Tab Arrow ...

Page 10: ...ck Tab engages Ceiling Mount 1 Remove the ceiling tile 2 Place the Ceiling Backing Plate in the center of the ceiling tile Mark the four mounting screw holes and an 18 mm hole for the Ethernet cable feed Optional 18 mm Hole for Ethernet Cable Feed through the Ceiling Tile ...

Page 11: ...and cut or drill the 18 mm hole for the Ethernet cable feed 4 Insert the Ceiling Screws through the Mounting Plate ceiling tile and Ceiling Backing Plate Fasten the screws using the Keps Nuts Then feed the Ethernet cable through the tile and bracket ...

Page 12: ...and then return to step 6 6 Align the Arrow on the top edge of the UAP XG with the Arrow on the Mounting Plate Lock Tab Arrow Arrow 7 Rotate the UAP XG clockwise until the tabs lock into place and the Lock Tab engages 8 Set the ceiling tile back into place ...

Page 13: ...nting 2 Loosen the set screws of the T Bar Mounts 3 Insert the T bar into a T Bar Mount and turn the T Bar Mount clockwise to attach it Use the included Allen Wrench to tighten the two set screws to secure the T Bar Mount 4 Attach the second T Bar Mount but do not tighten the set screws ...

Page 14: ...5 Use the two dashed lines on the Mounting Plate to space the T Bar Mounts 77 mm 3 apart 77 mm 6 Tighten the two set screws on the second T Bar Mount ...

Page 15: ...7 Insert the included T Bar Screws into the holes marked B on the Mounting Plate and then secure the plate to the T Bar Mounts 8 Drop the Ethernet cable between the plate and T bar ...

Page 16: ...d then return to step 10 10 Align the Arrow on the top edge of the UAP XG with the Arrow on the Mounting Plate Arrow Arrow Lock Tab 11 Rotate the UAP XG clockwise until the tabs lock into place and the Lock Tab engages 12 Set the ceiling tiles back into place ...

Page 17: ...allation 2 Pull the Ethernet cable through the Mounting Plate and attach the Mounting Plate to the junction or outlet box using at least two screws not included Note For in wall applications position the Mounting Plate with the Arrow pointing upwards 3 Perform the steps in the Connecting Ethernet section and then return to step 4 ...

Page 18: ...4 Align the Arrow on the top edge of the UAP XG with the Arrow on the Mounting Plate Lock Tab Arrow Arrow 5 Rotate the UAP XG clockwise until the tabs lock into place and the Lock Tab engages ...

Page 19: ...ble through the port cover Note The feed hole will stretch to accommodate the RJ45 connector and then seal around the cable 4 Connect the Ethernet cable to the 10 GbE port and replace the port cover Return to the appropriate instructions IC 6545A UAPXG Contains IC 6545A M442G Contains IC 6545A M445GL Contains IC 6545A M445GH FCC ID SWX UAPXG Contains FCC ID SWX M442G Contains FCC ID SWX M445GL Con...

Page 20: ...for power IMPORTANT Using the 10 GbE port requires enabling flow control on the upstream switch port s configuration for maximum performance Connecting to an 802 3bt PoE Switch Connect the Ethernet cable from the UAP XG directly to a PoE port on the switch 802 3bt PoE Switch ...

Page 21: ...uded with the single pack of the UAP XG 1 Connect the Ethernet cable from the UAP XG to the adapter s POE port 2 Connect an Ethernet cable from your LAN to the adapter s LAN port 3 Connect the Power Cord to the adapter s power port Connect the other end of the Power Cord to a power outlet ...

Page 22: ...click Log In You can manage your wireless network and view network statistics using the UniFi Controller management interface For information on configuring and using the UniFi Controller software refer to the User Guide Mobile App Installation Ubiquiti Networks also offers the UniFi mobile app which is available from the App Store iOS or Google Play Store Android You can use it to provision a Uni...

Page 23: ...oltage Range 44 57VDC Operating Frequency 2 4 GHz 5 GHz Max TX Power 2 4 GHz 5 GHz 25 dBm 25 dBm MIMO 2 4 GHz 5 GHz 4 x 4 4 x 4 Radio Rates 2 4 GHz 5 GHz 800 Mbps 1 7 Gbps Antenna Integrated Internal Antenna Antenna Gain 2 4 GHz 5 GHz 6 dBi 8 dBi Wi Fi Standards 802 11 a b g n ac ac wave2 Wireless Security WEP WPA PSK WPA Enterprise WPA WPA2 TKIP AES Mounting Wall Ceiling Junction Box Kits Include...

Reviews: