USW-Industrial
ESD/EMP Protection
Air: ± 24 kV, Contact: ± 24 kV
Shock and Vibration
ETSI300-019-1.4 Standard
Operating Temperature
Internal AC/DC @ 450W
-40 to 50° C (-40 to 122° F)
Internal AC/DC @ 240W
-40 to 60° C (-40 to 140° F)
Operating Humidity
5 to 95% Noncondensing
Certifications
CE, FCC, IC
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING:
Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of
clearance next to the ventilation holes for adequate airflow.
WARNING:
To reduce the risk of fire or electric shock, do not expose this product to rain or
moisture.
WARNING:
Do not use this product in location that can be submerged by water.
WARNING:
Avoid using this product during an electrical storm. There may be a remote risk of
electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated on
the manufacturer’s label. Connection to a different power source than those specified may result in
improper operation, damage to the equipment or pose a fire hazard if the limitations are not
followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only by a
qualified service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground wire
intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an
adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding
wire.
b. The equipment requires the use of the ground wire as a part of the safety certification,
modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation
i t
ti
th
i
t
USW-Industrial Quick Start Guide
Summary of Contents for UniFi USW-Industrial
Page 4: ...Wall Mounting 1 USW Industrial Quick Start Guide ...
Page 5: ...2 USW Industrial Quick Start Guide ...
Page 6: ...3 USW Industrial Quick Start Guide ...
Page 7: ...4 USW Industrial Quick Start Guide ...
Page 8: ...Connecting Power Connecting Ethernet 1 USW Industrial Quick Start Guide ...