background image

CE Marking

CE marking on this product represents the product is in compliance with all 
directives that are applicable to it.

Alert Sign (!) Follows CE Marking

Alert sign must be indicated if a restriction on use applied to the product 
and it must follow the CE marking.

RoHS/WEEE Compliance Statement

English

European Directive 2012/19/EU requires that the equipment bearing 
this symbol on the product and/or its packaging must not be disposed 
of with unsorted municipal waste. The symbol indicates that this 
product should be disposed of separately from regular household waste 
streams. It is your responsibility to dispose of this and other electric and 
electronic equipment via designated collection facilities appointed by the 
government or local authorities. Correct disposal and recycling will help 
prevent potential negative consequences to the environment and human 
health. For more detailed information about the disposal of your old 
equipment, please contact your local authorities, waste disposal service, or 
the shop where you purchased the product.

Deutsch

Die Europäische Richtlinie 2012/19/EU verlangt, dass technische 
Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem 
Symbol versehen ist, nicht zusammen mit unsortiertem Gemeindeabfall 
entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt 
von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es 
liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische 
und elektronische Geräte über die dafür zuständigen und von der 
Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu 
entsorgen. Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei, 
potentielle negative Folgen für Umwelt und die menschliche Gesundheit 
zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer 
Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder 
städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das 
Produkt erworben haben.

Summary of Contents for UniFi UAP-IW

Page 1: ...In Wall Wi Fi Access Point Model UAP IW ...

Page 2: ...y to follow local country regulations including operation within legal frequency channels output power indoor cabling requirements and Dynamic Frequency Selection DFS requirements Installation Requirements Pre installed electrical wall box Category 5 or above UTP cabling approved for indoor use Phillips screwdriver UniFi Switch with PoE Important The UAP IW requires a UniFi Switch with PoE for pow...

Page 3: ...d either on site and connected to the same Layer 2 network or off site in a cloud or NOC UAP IW US 48 500W USG PRO 4 DHCP Server Internet UAP AC PRO UAP AC PRO O UAP AC LR LAN WAN UniFi Cloud Key UniFi Controller Remote Access to UniFi Controller Sample Network Diagram All UniFi devices support off site management controllers For setup details see the User Guide on the website documentation ubnt c...

Page 4: ...ata only Used to connect a client device to the LAN PoE In Data 10 100 Ethernet port supports data and PoE Connect this port to a UniFi Switch that is connected to your LAN and DHCP server Reset The Reset button serves two functions for the UAP IW Restart Press and release the Reset button quickly Restore to Factory Default Settings Press and hold the Reset button for more than five seconds ...

Page 5: ...e is taking place Blue Indicates the device has been successfully integrated into a network and is working properly Quickly Flashing Blue This is used to locate an AP When you click Locate in the UniFi Controller software the AP will flash It will also display the location of the AP on the map Steady Blue with occasional flashing Indicates the device is in an isolated state all WLANs are brought d...

Page 6: ...n electrical wall box should be pre installed with an Ethernet cable running from the box to a UniFi Switch 1 Detach the Cover Plate from the UAP IW 2 Connect the Ethernet cable in the wall box to the port labeled PoE IN DATA ...

Page 7: ...operly position the cable to ensure the Ethernet connection is not strained Note If the wall box does not have enough room to accommodate the UAP IW without straining the Ethernet connection replace the wall box with an open end or deeper box ...

Page 8: ...d bottom screws Adjust the screws to ensure the mounting plate is flush with the wall for proper fitting of the Cover Plate Note Do not over tighten or rely on the force of the screws to pull the UAP IW into the wall box ...

Page 9: ...5 Attach the Cover Plate Press the Cover Plate into position until the four mounting clips snap into place If you are using your own cover plate secure it with two screws ...

Page 10: ...tation ubnt com unifi After you have installed the software and run the UniFi Installation Wizard a login screen will appear for the UniFi Controller management interface Enter the Admin Name and Password that you created and click Login You can manage your wireless network and view network statistics using the UniFi Controller management interface For information on configuring and using the UniF...

Page 11: ...on 6W Max TX Power 17 dBm Max Data Speed 150 Mbps Max Range 25 m 82 Antenna Gain 1 dBi Wi Fi Standards 802 11 b g n Wireless Security WEP WPA PSK WPA Enterprise WPA WPA2 TKIP AES Mounting 1 Gang Electrical Wall Box Not Included Operating Temperature 10 to 70 C 14 to 158 F Operating Humidity 5 to 95 Noncondensing Operating Band 2 4 GHz VLAN 802 1Q Advanced QOS Per User Rate Limiting Guest Traffic I...

Page 12: ...provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The...

Page 13: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...

Page 14: ...OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance including coverage buyer s selection of products including the Products for b...

Page 15: ...easonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in w...

Page 16: ...exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 1 Cet appareil ne peut pas provoquer d interférences et 2 Cet appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif Cet émetteur radio IC 6545A UAPRO a été approuvée par Industrie Canada pour l exploitation avec l antenne types énumérés c...

Page 17: ...th For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werde...

Page 18: ...que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre anci...

Page 19: ...ch Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befinde...

Page 20: ...iv UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivei 1999 5 CE Slovensky Slovak Týmto UBIQUITI NETWORKS prehlasuje že toto UBIQUITI NETWORKS zariadenie je v súlade so základnými požiadavkami a ďalšími relevantnými ustanoveniami smernice 1999 5 ES Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI N...

Reviews: