Ubiquiti TouchSwitch Poe TS-5-POE Quick Start Manual Download Page 13

11

General Warranty

General Warranty

UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and 

warrants that the Products furnished hereunder shall be free from defects 

in material and workmanship for a period of one (1) year from the date 

of shipment by UBIQUITI NETWORKS under normal use and operation. 

UBIQUITI NETWORKS sole and exclusive obligation under the foregoing 

warranty shall be to repair or replace, at its option, any defective Product 

that fails during the warranty period. The expense of removal and 

reinstallation of any item is not included in this warranty.
The foregoing warranty is exclusive and in lieu of all other warranties, 

express or implied, including the implied warranties of merchantability and 

fitness for a particular purpose and any warranties arising from a course 

of dealing, usage or trade practice with respect to the products. Repair or 

replacement in the manner provided herein shall be the sole and exclusive 

remedy of Buyer for breach of warranty and shall constitute fulfillment 

of all liabilities of UBIQUITI NETWORKS with respect to the quality and 

performance of the Products. UBIQUITI NETWORKS reserves the right 

to inspect all defective Products (which must be returned by Buyer to 

UBIQUITI NETWORKS factory freight prepaid).
No Products will be accepted for replacement or repair without obtaining 

a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS. 

Products returned without an RMA number will not be processed and will 

be returned to Buyer freight collect. UBIQUITI NETWORKS shall have no 

obligation to make repairs or replacement necessitated by catastrophe, 

fault, negligence, misuse, abuse, or accident by Buyer, Buyer’s customers or 

any other parties. The warranty period of any repaired or replaced Product 

shall not extend beyond its original term.

Warranty Conditions

The foregoing warranty shall apply only if:
(I) 

The Product has not been subjected to misuse, neglect or unusual 

physical, electrical or electromagnetic stress, or some other type of 

accident.

(II)  No modification, alteration or addition has been made to the Product 

by persons other than UBIQUITI NETWORKS or UBIQUITI NETWORK’S 

authorized representatives or otherwise approved by UBIQUITI 

NETWORKS.

(III)  The Product has been properly installed and used at all times in 

accordance, and in all material respects, with the applicable Product 

documentation.

(IV)  All Ethernet cabling runs use CAT5 (or above) shielded cabling.
Disclaimer: UBIQUITI NETWORKS does not warrant that the operation of 

the products is error-free or that operation will be uninterrupted. In no 

event shall UBIQUITI NETWORKS be responsible for damages or claims 

of any nature or description relating to system performance, including 

coverage, buyer’s selection of products for buyer’s application and/or 

failure of products to meet government or regulatory requirements.

Summary of Contents for TouchSwitch Poe TS-5-POE

Page 1: ...5 Port Power over Ethernet Managed Switch Model TS 5 POE ...

Page 2: ......

Page 3: ...eaturing 24V or 48V PoE TOUGHSwitch PoE Carrier TS 16 Carrier Two 8 Port TOUGHSwitch PoE PROs mounted in a rack For more information visit www ubnt com This Quick Start Guide is designed to guide you through the installation of the TOUGHSwitch and show you how to access the Configuration Interface Package Contents 5 Port TOUGHSwitch PoE M2 9x20 Screws Qty 2 M2 9 Anchors Qty 2 Carrier Class 5 Port ...

Page 4: ...nagement Traffic between the Management port and numbered ports will be limited to 10 100 Mbps and under heavy load may cause performance degradation of the TOUGHSwitch USB Reserved for future use 1 5 10 100 1000 Mbps ports for switching and PoE also available for management by default Reset To reset to factory defaults press and hold the Reset button for more than five seconds while the unit is a...

Page 5: ...If the link terminates the LED turns off until a link is re established If the unit reboots the LED will again indicate power until a link is established Amber Flashing Activity 1 5 PoE Off No Power over Ethernet Green 24V Power over Ethernet Speed Link Act Off No Link Amber Link Established at 10 100 Mbps Amber Flashing Link Activity at 10 100 Mbps Green Link Established at 1000 Mbps Green Flashi...

Page 6: ...n Requirements Drill and 6 mm drill bit Phillips screwdriver Instructions To mount the TOUGHSwitch on a wall 1 Use a 6 mm drill bit to drill two holes 60 mm apart 2 Insert the M2 9 Anchors into the holes 3 Use a Phillips screwdriver to secure a M2 9x20 Screw to each anchor Leave a clearance of approximately 3 mm between each screw head and its anchor 60 mm 3 mm Note You can also mount the TOUGHSwi...

Page 7: ...ck it into place Grounding the TOUGHSwitch Optional The TOUGHSwitch is grounded through the Power Adapter however you can add optional ESD grounding for enhanced ESD protection 1 Insert a ground wire not included through a corner slot 2 Twist tie to secure the ground wire to the TOUGHSwitch 3 Secure the other end of the ground wire to a grounding block ...

Page 8: ...rt Guide Connecting Power 1 Connect the power connector of the Power Adapter to the Power port of the TOUGHSwitch 2 Connect the Power Cord to the power port on the Power Adapter Connect the other end of the Power Cord to a power outlet ...

Page 9: ...agement port of the TOUGHSwitch 2 Connect Ethernet cables from the Ethernet ports of your devices to the numbered ports of the TOUGHSwitch Note PoE is disabled by default on all numbered ports and is not available on the Management port To enable PoE on the appropriate ports use the Ports tab in the Configuration Interface ...

Page 10: ...ort only You can configure this setting on the Device tab 2 Configure the Ethernet adapter on your host system with a static IP address on the 192 168 1 x subnet e g 192 168 1 100 3 Launch your web browser Type https 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Click Login The Configuration Interface wi...

Page 11: ...hod Passive Button Reset USB Port 2 0 Type A Reserved for Future Use Processor MIPS24K 400 MHz System Memory 64 MB Code Storage 8 MB Certifications CE FCC IC Wall Mount Yes Operating Temperature 25 to 55 C 13 to 131 F Operating Humidity 90 Non Condensing PoE Configurable Per Port Management N A Ports 1 5 Off 24V LEDs Per Port Management Link Activity Ports 1 5 PoE Speed Link Activity Networking In...

Page 12: ...ent Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of th...

Page 13: ...out obtaining a Return Materials Authorization RMA number from UBIQUITI NETWORKS Products returned without an RMA number will not be processed and will be returned to Buyer freight collect UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe fault negligence misuse abuse or accident by Buyer Buyer s customers or any other parties The warranty period...

Page 14: ...ed in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada This Class A digital apparatus complies with Canadian ICES 003 To reduce potential radio interference to o...

Page 15: ...isposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an de...

Page 16: ...e jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d...

Page 17: ... Finnish UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deuts...

Page 18: ... príslu né ustanovenia Smernice 1999 5 ES Svenska Swedish Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera...

Page 19: ......

Page 20: ...t Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks Inc All rights reserved ...

Reviews: