2. Feed a DC cable (not included, maximum size: 14AWG) through
the hole and wire to the SLA terminal block.
WARNING:
We strongly recommend that you add
an appropriate DC breaker (interrupter) between the
SLA|Tbatt terminal block and external battery to increase
safety during installation or maintenance. Suggested
breaker rating: 30VDC/10A.
3. Wire the other end to a lead acid (AGM/flooded or gel) battery.
4. Feed the included NTC Thermistor through the hole and wire it
to the Tbatt terminal block. (You can use a cable to extend the
NTC Thermistor as needed.)
5. Attach the other end of the NTC Thermistor to your battery.