background image

Safety Notices

1.  Read, follow, and keep these instructions.
2.  Heed all warnings.
3.  Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in location that can 

be submerged by water. 

WARNING:

 Avoid using this product during an electrical 

storm. There may be a remote risk of electric shock from 
lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

3.  This equipment is provided with a detachable power cord which has 

an integral safety ground wire intended for connection to a grounded 
safety outlet.
a.  Do not substitute the power cord with one that is not the provided 

approved type. Never use an adapter plug to connect to a 2-wire 
outlet as this will defeat the continuity of the grounding wire. 

b.  The equipment requires the use of the ground wire as a part of the 

safety certification, modification or misuse can provide a shock 
hazard that can result in serious injury or death.

c.  Contact a qualified electrician or the manufacturer if there 

are questions about the installation prior to connecting the 
equipment.

d.  Protective earthing is provided by Listed AC adapter. Building 

installation shall provide appropriate short-circuit backup 
protection.

e.  Protective bonding must be installed in accordance with local 

national wiring rules and regulations.

Summary of Contents for PowerBean fante

Page 1: ...5 GHz High Performance airMAX ac Gen 2 Radio Bridge Model PBE 5AC Omni Gen2...

Page 2: ...gory 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE We recommend that you protect your networks from the most brutal envir...

Page 3: ...ed on Alternatively the PowerBeam may be reset remotely via a Reset button located on the bottom of the Gigabit PoE Adapter Release Button After you assemble the PowerBeam check the Release button it...

Page 4: ...is equal to or above 73 dBm LED will light blue when the wireless signal strength is equal to or above 80 dBm LED will light blue when the wireless signal strength is equal to or above 94 dBm Etherne...

Page 5: ...Installation 1 Push in the sides of the Cable Door and detach it from the Rear Housing 2 Insert the Antenna Feed with Omni into the Rear Housing and push until it locks into place with a click...

Page 6: ...3 Connect an Ethernet cable to the Ethernet Port of the Antenna Feed and re attach the Cable Door to the Rear Housing 640 12345 01 640 12345 01...

Page 7: ...4 Attach the Rear Housing to the Mounting Bracket with four Bolts...

Page 8: ...5 Insert the U Bolt into the Pole Clamp and Mounting Bracket Secure each end of the U Bolt with a Washer and a Flange Nut Note The mounting assembly can accommodate a 32 56 mm pole...

Page 9: ...Ethernet port labeled POE on the Gigabit PoE Adapter 7 Connect an Ethernet cable from your LAN or computer to the Ethernet port labeled LAN on the adapter 8 Connect the Power Cord to the power port o...

Page 10: ...oE Adapter 2 Place the PoE Mounting Bracket at the desired location and mark the two holes Pre drill the holes if necessary and then secure the bracket using two fasteners not included 3 Align the slo...

Page 11: ...ss enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Log...

Page 12: ...er s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna a...

Page 13: ...upply 24V 0 5A Gigabit PoE Supply Included Power Method Passive PoE Pairs 4 5 7 8 Return Wind Survivability 200 km h 125 mph Certifications CE FCC IC Mounting Pole Mounting Kit Included Operating Temp...

Page 14: ...rovided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a...

Page 15: ...addition made thereto except by Ubiquiti Networks or Ubiquiti Networks authorized representatives or as approved by Ubiquiti Networks in writing II has been painted rebranded or physically modified i...

Page 16: ...LAR PURPOSE AND NON INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NE...

Page 17: ...f implied warranties or conditions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states...

Page 18: ...ticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to cor...

Page 19: ...nce aux autres utilisateurs le type d antenne et son gain doivent tre choisies de fa on que la puissance isotrope rayonn e quivalente PIRE ne d passe pas ce qui est n cessaire pour une communication r...

Page 20: ...transmetteur doivent tre install en consid rant une distance de s paration de toute personnes d au moins 94 516 cm et ne doivent pas tre localis ou utilis en conflit avec tout autre antenne ou transme...

Page 21: ...ice or the shop where you purchased the product Deutsch Die Europ ische Richtlinie 2002 96 EC verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol verse...

Page 22: ...insi que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bo...

Page 23: ...ch Par la pr sente UBIQUITI NETWORKS d clare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hi...

Page 24: ...y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Polski Polish Niniejszym Ubiquiti Networks o wiadcza e urz dzenie UBIQUITI NETWORKS jest zgodny z zasadniczymi wymag...

Reviews: