Specifications

GBE

Dimensions

140 x 140 x 90 mm (5.51 x 5.51 x 3.54")

Weight

376 g (13.3 oz)

Gain

5 GHz
60 GHz

10 dBi

17.2 dBi

Networking Interface

10/100/1000 Ethernet Port

Wi-Fi for Management

Enclosure

UV-Resistant Polycarbonate

Max. Power Consumption

11W

Power Supply

24V, 0.5A Gigabit PoE Adapter (Included)

24V, 1A if Using Motor Accessory

Power Method

Passive PoE (Pairs 4, 5+; 7, 8-)

Wind Loading

56 N @ 200 km/h (12.6 lbf @ 125 mph)

Wind Survivability

200 km/h (125 mph)

Mounting

Pole-Mount (Kit Included)

Wall-Mount (Not Included)

ESD/EMP Protection

± 24kV Contact/Air

Operating Temperature

-40 to 70° C (-40 to 158° F)

Operating Humidity

5 to 95% Noncondensing

Certifications

CE, FCC, IC

Operating Frequency (MHz)

Worldwide

5180 - 5875 

57,000 - 66,000

US/CA

U-NII-1: 

5180 - 5250

U-NII-3:

5725 - 5850

57,000 - 66,000

Management Radio (MHz)

Worldwide

2412 - 2472

US/CA

2412 - 2462

Summary of Contents for GigaBeam GBE

Page 1: ...60 GHz 5 GHz Radio System with 1 Gbps Throughput Model GBE ...

Page 2: ...Package Contents GBE Ball Joint Mount Lock Ring Metal Strap Gigabit PoE 24V 0 5A with Mounting Bracket Power Cord ...

Page 3: ...ect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti For more details visit ui com toughcable Surge protection should be used for all outdoor installations We recommend that you use two Ethernet Surge Protectors model ETH SP G2 one near the device and the other at the entry point to the building The ETH SP G2 wil...

Page 4: ... for more than 10 seconds while the device is powered on Alternatively the device may be reset remotely via a Reset button located on the bottom of the Gigabit PoE Adapter 2 Ethernet Port This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server ...

Page 5: ...e Ethernet connection is made to the Ethernet port and flash when there is activity 7 Power Status Color Status Flashing White Bootup is in progress White Ready for use UNMS is disabled Blue Ready for use UNMS is enabled and connected Steady Blue with Occasional Flashing Ready for use UNMS is enabled but not connected Quickly Flashing Blue Used to locate device from UNMS or web Alternating Blue Wh...

Page 6: ...Hardware Installation Go to the appropriate mounting instructions Pole Mounting or Wall Mounting Pole Mounting 1 2 ...

Page 7: ...3 4 ...

Page 8: ...surface to avoid damage to the mounting hole when you adjust the aim Optional Accessory To enhance stability you can use the NanoBeam Wall Mount Kit model NBE WMK sold separately Note Center screw included Two optional screws not included provide additional stability Installation Instructions 1 ...

Page 9: ...2 3 OR Fastener not included NanoBeam Wall Mount Kit 4 ...

Page 10: ...Aiming 1 2 ...

Page 11: ...Connecting Power 1 2 3 ...

Page 12: ...4 WARNING The switch port must comply with the power specifications listed in Specifications OR Mounting the PoE Adapter Optional ...

Page 13: ...ice to re enable its Wi Fi UNMS App 1 Download the UNMS app 2 Connect your device s Wi Fi to the SSID named GBE MAC Address Note Ensure that DHCP is enabled on your Wi Fi adapter 3 Launch the app and follow the on screen instructions Web Portal 1 Connect your device s Wi Fi to the SSID named GBE MAC Address Note Ensure that your Wi Fi connection has DHCP enabled 2 Launch a web browser and go to ht...

Page 14: ...product Click Continue 4 Create a username and password Confirm your new password and then click Save The airOS Configuration Interface will appear allowing you to customize your settings as needed For additional details refer to the User Guide available at ui com download airmax ac ...

Page 15: ...onally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Output Power field is provided to the professional installer to assist in meeting regulatory requirements ...

Page 16: ...Using Motor Accessory Power Method Passive PoE Pairs 4 5 7 8 Wind Loading 56 N 200 km h 12 6 lbf 125 mph Wind Survivability 200 km h 125 mph Mounting Pole Mount Kit Included Wall Mount Not Included ESD EMP Protection 24kV Contact Air Operating Temperature 40 to 70 C 40 to 158 F Operating Humidity 5 to 95 Noncondensing Certifications CE FCC IC Operating Frequency MHz Worldwide 5180 5875 57 000 66 0...

Page 17: ...ich has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The equipment requires the use of the ground wire as a part of the safety certification modification or misuse ...

Page 18: ...f this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This radio transmitter has been approved by FCC ISED Canada CAN ICES 3 A NMB 3 A This device complies with ISED Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause inte...

Page 19: ...or transmitter AVIS IMPORTANT Déclaration sur l exposition aux rayonnements Cet équipement est conforme aux limites prévues pour l exposition aux rayonnements dans un environnement non contrôlé Lors de l installation et de la mise en fonctionnement de l équipement assurez vous qu il y ait une distance minimale de 33 cm entre l élément rayonnant et vous Cet émetteur ne doit être installé à proximit...

Page 20: ... is prohibited in BFWA member states Other countries listed may use the 5 8 GHz frequency band RoHS WEEE Compliance Statement English European Directive 2012 19 EU requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately from regular household was...

Page 21: ...uiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas Si desea obtener información más detallada sobre la eliminación segura de su aparato usa...

Page 22: ...4 30 EU 2014 35 EU Úplné znění EU prohlášení o shodě je k dispozici na této internetové adrese ui com compliance Dansk Danish Hermed UBIQUITI erklærer at denne GBE enhed er i overensstemmelse med de væsentlige krav og øvrige relevante krav i direktiver 2014 53 EU 2014 30 EU 2014 35 EU EU overensstemmelseserklæringens fulde tekst kan findes på følgende internetadresse ui com compliance Nederlands D...

Page 23: ... ES Direktyvų nuostatas Visas ES atitikties deklaracijos tekstas prieinamas šiuo interneto adresu ui com compliance Malti Maltese Hawnhekk UBIQUITI tiddikjara li dan il mezz GBE huwa konformi mar rekwiżiti essenzjali u dispożizzjonijiet rilevanti oħrajn ta Direttivi 2014 53 UE 2014 30 UE 2014 35 UE Id dikjarazzjoni tal konformità tista tiġi kkonsultata minn ui com compliance Norsk Norwegian Herved...

Page 24: ...demarks are the property of their respective owners AI072219 Español Spanish Por medio de la presente UBIQUITI declara que este dispositivo GBE cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de las Directivas 2014 53 UE 2014 30 UE 2014 35 UE El texto completo de la declaración UE de conformidad está disponible en la dirección Internet siguiente ui co...

Reviews: