Summary of Contents for EdgeRouter ER-8

Page 1: ...8 Port Router Model ER 8 https arttel ru https arttel ru shop marshrutizatory ubiqu ...

Page 2: ... 32 x 5 8 Qty 4 Cage Nuts 10 32 x 5 8 Qty 4 8 Port Router Model ER 8 Power Cord Quick Start Guide TERMS OF USE All Ethernet cabling runs must use CAT5 or above It is the customer s responsibility to follow local country regulations including operation within legal frequency channels output power indoor cabling requirements and Dynamic Frequency Selection DFS requirements https arttel ru https artt...

Page 3: ...hould be grounded through the AC ground of the power supply We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable WARNING To reduce the risk of fire or electric shock do not expose the EdgeRouter to rain or moisture Note Although the...

Page 4: ... a rollover cable to connect the Console port to your computer If your computer does not have a DB9 port then you will also need a DB9 adapter Then configure the following settings as needed Baud rate 115200 Data bits 8 Parity NONE Stop bits 1 Flow control NONE USB Reserved for future use RJ45 eth0 eth7 RJ45 ports support 10 100 1000 Ethernet connections https arttel ru https arttel ru shop marshr...

Page 5: ... on RJ45 port eth7 starts flashing and then becomes solidly lit After a few seconds the LED will turn off and the EdgeRouter will automatically reboot Power on reset Disconnect the Power Cord from the EdgeRouter Press and hold the Reset button while connecting the Power Cord to the EdgeRouter Keep holding the button until the right LED on RJ45 port eth7 starts flashing and then stops flashing afte...

Page 6: ...Amber Link Established at 10 100 Mbps Amber Flashing Link Activity at 10 100 Mbps Green Link Established at 1000 Mbps Green Flashing Link Activity at 1000 Mbps Power White 8 Port EdgeRouter is powered on Back Panel Mounting Holes Power Ventilation Holes Mounting Holes Fans Note There are additional ventilation holes on the sides of the EdgeRouter https arttel ru https arttel ru shop marshrutizator...

Page 7: ... OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW 1 Attach the EdgeRouter to the rack using the four Mounting Screws If the rack has square slots then use the Cage Nuts with the Mounting Screws 2 Connect the Power Cord to the Power port https arttel ru https arttel ru shop marshrutizatory ubiqu ...

Page 8: ...ernet port of your computer to the port labeled eth0 on the 8 Port EdgeRouter 2 Configure the Ethernet adapter on your host system with a static IP address on the 192 168 1 x subnet 3 Launch your web browser Type https 192 168 1 1 in the address field Press enter PC or return Mac https arttel ru https arttel ru shop marshrutizatory ubiqu ...

Page 9: ...this License Agreement to accept it Click Login The EdgeOS Configuration Interface will appear allowing you to customize your settings as needed You can click the Wizards tab to access the Setup Wizard For more information refer to the EdgeOS User Guide which is available at documentation ubnt com edgemax https arttel ru https arttel ru shop marshrutizatory ubiqu ...

Page 10: ...ation for Packet Processing System Memory 2 GB DDR3 RAM Code Storage 4 GB LEDs Serial Console Port Data Ports N A Speed Link Activity Networking Interfaces Serial Console Port Data Ports 1 RJ45 Serial Port 8 10 100 1000 RJ45 Ethernet Ports Certifications CE FCC IC Rack Mount Yes ESD EMP Protection Air 24 kV Contact 24 kV Operating Temperature 10 to 45 C 14 to 113 F Operating Humidity 10 90 Noncond...

Page 11: ... not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter p...

Page 12: ... by Ubiquiti Networks or Ubiquiti Networks authorized representatives or as approved by Ubiquiti Networks in writing II has been painted rebranded or physically modified in any way III has been damaged due to errors or defects in cabling IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged...

Page 13: ...MENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYER S EQUIPMENT OR THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES INCLUDING THE INTERNET AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT TO LIMITATIONS INTERRUPTIONS DELAYS C...

Page 14: ...itions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages so the above limitation may not apply to you EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW THESE WARRANTY TERMS DO NOT EXCLU...

Page 15: ...s uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada CAN ICES 3 A NMB 3 A This Class A...

Page 16: ...ased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung dieses Gerät und an...

Page 17: ...ique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ancien équipement veuillez prendre...

Page 18: ...S déclare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes des directives 2014 30 UE 2014 35 UE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinien 2014 30 EU 2014 35 EU befindet Ελληνική ...

Page 19: ...nciais e outras disposições das Directivas 2014 30 UE 2014 35 UE Română Romanian Prin prezenta UBIQUITI NETWORKS declară că acest dispozitiv UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivelor 2014 30 UE 2014 35 UE Slovensky Slovak Týmto UBIQUITI NETWORKS prehlasuje že toto UBIQUITI NETWORKS zariadenie je v súlade so základnými požiadavkami a ...

Page 20: ...beam logo EdgeMAX EdgeOS EdgeSwitch and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners PHJL041516 w w w u b n t c o m https arttel ru https arttel ru shop marshrutizatory ubiqu ...