background image

12

airGrid

 AGM5-HP-1724 Quick Start Guide

5.  Select the airGrid antenna size:

a.  Click the Wireless tab.
b.  From the Antenna drop-down list, select the appropriate 

option.

c.  Click Change to save.
d.  Click OK to confirm.

Customize additional settings as needed to complete 
the installation. Please review the Installer Compliance 
Responsibility section on the following page.
For additional details on the airOS Configuration Interface, refer 
to the User Guide available at documentation.ubnt.com

Summary of Contents for airMAX airGrid M5HP

Page 1: ...5 GHz High Performance Model M5GHP ...

Page 2: ......

Page 3: ...w you how to access the airOS Configuration Interface Package Contents Antenna Feed Feed Extender Grid Reflector Rear Housing L Bracket Pole Clamp M8 U Bolt 5 GHz High Performance Integrated InnerFeed Antenna Model AGM5 HP 1724 M8 Flange Nuts Qty 2 PoE Adapter 24V 0 5A Power Cord Quick Start Guide Grid reflector and mounting hardware packaged separately Products may be different from pictures and ...

Page 4: ...works from the most brutal environments and devastating ESD attacks with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable Application Examples The airGrid mounted outdoors with the Grid Reflector installed provides directional outdoor coverage gain reflector dependent The airGrid mounted outdoors without the Grid Reflector installed pro...

Page 5: ...th is above 65 dBm LED will light green when the wireless signal strength is above 73 dBm LED will light amber when the wireless signal strength is above 80 dBm LED will light red when the wireless signal strength is above 94 dBm Ethernet The Ethernet LED will light steady green when an active Ethernet connection is made and flash when there is activity Power The Power LED will light green when th...

Page 6: ...liding the tabs into the slots Vertical Polarization Horizontal Polarization WARNING The polarization of the airGrid must match the polarization of its corresponding device horizontal to horizontal vertical to vertical 2 On the front of the airGrid ensure the polarization mark V or H properly matches your desired polarization Vertical Polarization Horizontal Polarization ...

Page 7: ...locking tab of the cable feed door facing up c Insert the alignments pins of the Rear Housing into the alignment holes and push until the Rear Housing locks into place with a click Vertical Polarization Horizontal Polarization 4 Insert the Feed Extender into the Rear Housing with the Release Button facing down Push until it locks into place with a click Release Button ...

Page 8: ...t Guide 5 Lift the locking tab of the cable feed door and detach the door from the Rear Housing 6 Route an Ethernet cable through the Rear Housing and Feed Extender Connect the cable to the Ethernet port on the back of the Antenna Feed ...

Page 9: ...tion b Insert the Antenna Feed into the Feed Extender and push until it locks into place with a click Vertical Polarization Horizontal Polarization 8 Lightly pull the Antenna Feed to ensure that the Release Button is fully engaged and locked into place Antenna Feed Feed Extender Release Button Bottom View ...

Page 10: ...enna Feed polarization matches the Grid Reflector polarization shown in step 2 Vertical Polarization Horizontal Polarization Note If you need to remove the Antenna Feed you must depress the Release Button first 10 Re attach the cable feed door to the Rear Housing Ensure the locking tab securely latches to the Rear Housing ...

Page 11: ... Slide the Pole Clamp onto the L Bracket 12 Insert the M8 U Bolt into the Pole Clamp and L Bracket Secure each end of the M8 U Bolt with a M8 Flange Nut 9 N m 80 lb in Note The mounting assembly can accommodate a Ø 1 25 2 2 pole ...

Page 12: ...the Ethernet cable from the airGrid to the Ethernet port labeled POE on the PoE Adapter 2 Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 3 Connect the Power Cord to the power port on the PoE Adapter Connect the other end of the Power Cord to a power outlet ...

Page 13: ...our host system with a static IP address on the 192 168 1 x subnet 3 Launch your web browser and type https 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Coun...

Page 14: ...t the appropriate option c Click Change to save d Click OK to confirm Customize additional settings as needed to complete the installation Please review the Installer Compliance Responsibility section on the following page For additional details on the airOS Configuration Interface refer to the User Guide available at documentation ubnt com ...

Page 15: ... professional installer s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements ...

Page 16: ...requency Worldwide 5170 5875 MHz USA 5725 5825 MHz Gain 28 dBi Max Power Consumption 3 0 W Power Supply 24V 0 5A PoE Adapter Included Power Method Passive Power over Ethernet Pairs 4 5 7 8 Return Max VSWR 1 5 1 Wind Survivability 125 mph Wind Loading 5 lbf 100 mph ETSI Specification EN 302 326 DN2 Shock and Vibration ETSI300 019 1 4 Certifications FCC IC CE Operating Temperature 30 to 75 C Operati...

Page 17: ...hould be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding w...

Page 18: ... returned without an RMA number will not be processed and will be returned to Buyer freight collect UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe fault negligence misuse abuse or accident by Buyer Buyer s customers or any other parties The warranty period of any repaired or replaced Product shall not extend beyond its original term EXCEPT FOR...

Page 19: ...s in accordance and in all material respects with the applicable Product documentation IV All Ethernet cabling runs use CAT5 or above shielded cabling Disclaimer UBIQUITI NETWORKS does not warrant that the operation of the products is error free or that operation will be uninterrupted In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to ...

Page 20: ... 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital de...

Page 21: ...paration distance of at least 55 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d au moins 55 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur CE Marking CE marki...

Page 22: ...sche und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu entsorgen Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei potentielle negative Folgen für Umwelt und die menschliche Gesundheit zu vermeiden Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgeräte benötigen wenden Sie sich bitte an die örtlichen Behörd...

Page 23: ...voirs publics locaux le service de traitement des déchets ou l endroit où vous avez acheté le produit Italiano La direttiva europea 2002 96 EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e o sull imballaggio non siano smaltite insieme ai rifiuti urbani non differenziati Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti dome...

Page 24: ...e Suomi Finnish UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 C...

Page 25: ...y a v etky príslu né ustanovenia Smernice 1999 5 ES Svenska Swedish Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cu...

Page 26: ...s redes de los entornos más hostiles y los devastadores efectos de las descargas electrostáticas utilizando cable Ethernet blindado con calidad industrial de Ubiquiti Networks Para obtener más información visite www ubnt com toughcable Français Nous vous recommandons de protéger vos réseaux contre les environnements les plus brutaux et les décharges électrostatiques les plus dévastatrices avec un ...

Page 27: ......

Page 28: ...w w w u b n t c o m 2013 Ubiquiti Networks Inc All rights reserved Support support ubnt com Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com ...

Reviews: