background image

1

Introduction

Introduction

Thank you for purchasing the Ubiquiti Networks airGrid

 2.4 GHz 

High-Performance Integrated InnerFeed Antenna, model 
AGM2-HP-1114. This Quick Start Guide is designed to walk you 
through the installation of the airGrid.

Package Contents

2

2.4 GHz High-Performance 

Integrated InnerFeed 

Antenna
Model: AGM2-HP-1114

11x14" Grid Reflector

Antenna Feed*

Feed Support*

Quick Start Guide

L Bracket

Pole Clamp

M6 U Bolt

M6x20 Bolts 

(Qty. 4)

M6 Serrated  

Flange Nuts  

(Qty. 2)

M6 Washers 

(Qty. 4)

M6 Lock Washers 

(Qty. 4)

Feed Support  

Bushing*

PoE Adapter* 

(24V, 0.5A)

Power Cord*

*  Items marked with an asterisk may be packaged separately. Products may be 

different from pictures and are subject to change without notice.

Summary of Contents for AGM2-HP-1114

Page 1: ...2 2 4 GHz High Performance Integrated InnerFeed Antenna Model AGM2 HP 1114 ...

Page 2: ......

Page 3: ...ntents 2 2 4 GHz High Performance Integrated InnerFeed Antenna Model AGM2 HP 1114 11x14 Grid Reflector Antenna Feed Feed Support Quick Start Guide L Bracket Pole Clamp M6 U Bolt M6x20 Bolts Qty 4 M6 Serrated Flange Nuts Qty 2 M6 Washers Qty 4 M6 Lock Washers Qty 4 Feed Support Bushing PoE Adapter 24V 0 5A Power Cord Items marked with an asterisk may be packaged separately Products may be different...

Page 4: ...s visit www ubnt com toughcable Hardware Installation 1 Attach the Feed Support and L Bracket to the Grid Reflector a Orient the Grid Reflector for the appropriate polarization horizontal or vertical WARNING The polarization of the airGrid must match the polarization of its corresponding device horizontal to horizontal vertical to vertical b With the cable opening facing down insert the Feed Suppo...

Page 5: ...3 Hardware Installation 2 Route an Ethernet cable through the cable opening of the Feed Support and connect it to the Ethernet port on the back of the Antenna Feed ...

Page 6: ... Horizontal Polarization Vertical Polarization WARNING The orientation of the Antenna Feed and Grid Reflector must match the orientation required for your signal polarization horizontal or vertical 4 Wrap the Feed Support Bushing around the Ethernet cable and then push it into the cable opening of the Feed Support ...

Page 7: ...commodate a Ø 1 25 2 2 pole a Ensure that the cable opening of the Feed Support faces down b Insert the M6 U Bolt into the Pole Clamp and L Bracket c Secure the M6 U Bolt with two M6 Serrated Flange Nuts d Tighten all nuts to approximately 14 N m 10 lb ft or less to avoid deforming the pole ...

Page 8: ...the Ethernet cable from the airGrid to the Ethernet port labeled POE on the PoE Adapter 2 Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 3 Connect the Power Cord to the power port on the PoE Adapter Connect the other end of the Power Cord to a power outlet ...

Page 9: ... static IP address on the 192 168 1 x subnet 3 Launch your web browser and type http 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ensure comp...

Page 10: ...ller Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna and Output Power fields are provided to the professional installer to assist in meeting regulat...

Page 11: ...R 1 5 1 Wind Survivability 125 mph Wind Loading 5 lbf 100 mph ETSI Specification EN 302 326 DN2 Shock and Vibration ETSI300 019 1 4 Certifications FCC IC CE Operating Temperature 30 to 75 C Operating Humidity 5 to 95 Condensing Mounting Universal Pole Mount Included Safety Notices 1 Read follow and keep these instructions 2 Heed all warnings 3 Only use attachments accessories specified by the manu...

Page 12: ... Building installation shall provide appropriate short circuit backup protection e Protective bonding must be installed in accordance with local national wiring rules and regulations General Warranty UBIQUITI NETWORKS Inc UBIQUITI NETWORKS represents and warrants that the Products furnished hereunder shall be free from defects in material and workmanship for a period of one 1 year from the date of...

Page 13: ...duct has been properly installed and used at all times in accordance and in all material respects with the applicable Product documentation IV All Ethernet cabling runs use CAT5 or above shielded cabling Disclaimer UBIQUITI NETWORKS does not warrant that the operation of the products is error free or that operation will be uninterrupted In no event shall UBIQUITI NETWORKS be responsible for damage...

Page 14: ...users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including int...

Page 15: ...ated if a restriction on use applied to the product and it must follow the CE marking RoHS WEEE Compliance Statement English European Directive 2002 96 EC requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately from regular household waste stream...

Page 16: ...a desechar este y cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas Si desea obtener información más detallada sobre la eliminación...

Page 17: ...evice overholder de væsentlige krav og øvrige relevante krav i direktiv 1999 5 EF Nederlands Dutch Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999 5 EG Bij deze verklaart UBIQUITI NETWORKS dat deze UBIQUITI NETWORKS device voldoet aan de essentiële eisen en aan de overige...

Page 18: ... jikkonforma mal ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid Dirrettiva 1999 5 EC Norsk Norwegian UBIQUITI NETWORKS erklærer herved at utstyret UBIQUITI NETWORKS device er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999 5 EF Slovensky Slovak UBIQUITI NETWORKS t mto vyhlasuje e UBIQUITI NETWORKS device sp a základné po iadavky a v etky príslu né ...

Page 19: ......

Page 20: ...t Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks Inc All rights reserved ...

Reviews: