Ubiquiti 60G-Link Quick Start Manual Download Page 17

Safety Notices

1.  Read, follow, and keep these instructions.
2.  Heed all warnings.
3.  Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in a location that can 

be submerged by water. 

WARNING:

 Avoid using this product during an electrical 

storm. There may be a remote risk of electric shock from 
lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

3.  This equipment is provided with a detachable power cord which has 

an integral safety ground wire intended for connection to a grounded 
safety outlet.
a.  Do not substitute the power cord with one that is not the provided 

approved type. Never use an adapter plug to connect to a 2-wire 
outlet as this will defeat the continuity of the grounding wire. 

b.  The equipment requires the use of the ground wire as a part of the 

safety certification, modification or misuse can provide a shock 
hazard that can result in serious injury or death.

c.  Contact a qualified electrician or the manufacturer if there 

are questions about the installation prior to connecting the 
equipment.

d.  Protective earthing is provided by Listed AC adapter. Building 

installation shall provide appropriate short-circuit backup 
protection.

e.  Protective bonding must be installed in accordance with local 

national wiring rules and regulations.

Limited Warranty

ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on 
an individual basis, and, where applicable, specify arbitration instead of 
jury trials or class actions.

Summary of Contents for 60G-Link

Page 1: ...60 GHz 5 GHz Radio System with 1 Gbps Throughput Model 60G Link...

Page 2: ...Package Contents 60G Link Ball Joint Mount Lock Ring Metal Strap Gigabit PoE 24V 0 5A with Mounting Bracket Power Cord...

Page 3: ...your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti For more details visit ui com toughcable Surge protection should...

Page 4: ...for more than 10 seconds while the device is powered on Alternatively the device may be reset remotely via a Reset button located on the bottom of the Gigabit PoE Adapter 2 Ethernet Port This Gigabit...

Page 5: ...Ethernet connection is made to the Ethernet port and flash when there is activity 7 Power Status Color Status Flashing White Bootup is in progress White Ready for use UNMS is disabled Blue Ready for u...

Page 6: ...Hardware Installation Go to the appropriate mounting instructions Pole Mounting or Wall Mounting Pole Mounting 1 2...

Page 7: ...3 4...

Page 8: ...urface to avoid damage to the mounting hole when you adjust the aim Optional Accessory To enhance stability you can use the NanoBeam Wall Mount Kit model NBE WMK sold separately Note Center screw incl...

Page 9: ...2 3 OR Fastener not included NanoBeam Wall Mount Kit 4...

Page 10: ...Aiming 1 2...

Page 11: ...Connecting Power 1 2...

Page 12: ...cluded Gigabit PoE Adapter PoE switch WARNING The switch port must comply with the power specifications listed in the Specifications section of this Quick Start Guide Connecting to the PoE Adapter Mou...

Page 13: ...re enable its Wi Fi UNMS App 1 Download the UNMS app 2 Connect your device s Wi Fi to the SSID named 60G Link MAC Address Note Ensure that DHCP is enabled on your Wi Fi adapter 3 Launch the app and f...

Page 14: ...roduct Click Continue 4 Create a username and password Confirm your new password and then click Save The airOS Configuration Interface will appear allowing you to customize your settings as needed For...

Page 15: ...nally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Output Power field is provided to the profess...

Page 16: ...f Using Motor Accessory Power Method Passive PoE Pairs 4 5 7 8 Wind Loading 56 N 200 km h 12 6 lbf 125 mph Wind Survivability 200 km h 125 mph Mounting Pole Mount Kit Included Wall Mount Not Included...

Page 17: ...ch has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug t...

Page 18: ...dio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Thi...

Page 19: ...on aux rayonnements dans un environnement non contr l Lors de l installation et de la mise en fonctionnement de l quipement assurez vous qu il y ait une distance minimale de 20 cm entre l l ment rayon...

Page 20: ...is prohibited in BFWA member states Other countries listed may use the 5 8 GHz frequency band RoHS WEEE Compliance Statement English European Directive 2012 19 EU requires that the equipment bearing t...

Page 21: ...alesquiera otros aparatos el ctricos y electr nicos a trav s de los puntos de recogida que ponen a su disposici n el gobierno y las autoridades locales Al desechar y reciclar correctamente estos apara...

Page 22: ...ven mi sm rnic 2014 53 EU 2014 30 EU 2014 35 EU pln zn n EU prohl en o shod je k dispozici na t to internetov adrese ui com compliance Dansk Danish Hermed UBIQUITI erkl rer at denne 60G Link enhed er...

Page 23: ...rneta vietn ui com compliance Lietuvi kalba Lithuanian UBIQUITI deklaruoja kad is 60G Link renginys atitinka esminius reikalavimus ir kitas 2014 53 ES 2014 30 ES 2014 35 ES Direktyv nuostatas Visas ES...

Page 24: ...drugimi ustreznimi dolo bami direktiv 2014 53 EU 2014 30 EU in 2014 35 EU Celotno besedilo izjave EU o skladnosti je na voljo na naslednjem spletnem naslovu ui com compliance Espa ol Spanish Por medi...

Reviews: