background image

9. 9. 2019

USW-Industrial Quick Start Guide

https://dl.ubnt.com/qsg/USW-Industrial/USW-Industrial_EN.html

13/18

2. On the Devices screen, locate the UniFi Switch in the list of devices under the Model

column. To adopt the UniFi Switch, click Adopt.

USW-Industrial Quick Start Guide

Summary of Contents for 0817882026758

Page 1: ...Industrial_EN html 1 18 UniFi Switch Screws Qty 6 Screw Anchors Qty 6 Power Cord Package Contents Installation Requirements Drill with 6 mm drill bit Phillips screwdriver Cat5 6 UTP cable for indoor installations Plenum rated cabling for plenum spaces USW Industrial Quick Start Guide ...

Page 2: ...er browsers may have limited functionality UniFi Controller software v5 10 x or newer available at ui com download unifi Hardware Overview Flashing White Initializing Steady White Factory defaults waiting for adoption Alternating White Blue Device is busy do not touch or unplug it This usually indicates that a process such as a firmware upgrade is taking place Steady Blue Successfully adopted by a...

Page 3: ...tware the System LED will flash blue The software will also display the location of the UniFi Switch on the map Off PoE Disabled Amber 802 3af at bt PoE Off No Link Amber Link Established at 10 or 100 Mbps Flashing Indicates Activity Green Link Established at 1000 Mbps 1 Gbps Flashing Indicates Activity RJ45 ports support 10 100 1000 Ethernet connections and 802 3af at bt PoE output RJ45 ports sup...

Page 4: ...uickly Restore to Factory Default Settings Press and hold the Reset button for more than five seconds Hardware Installation You have two options for mounting Screws and Screw Anchors You can use the included Screws and Screw Anchors Go to Wall Mounting Machine Screws You can use eight M4 machine screws not included which must be long enough to extend 6 mm into the Switch USW Industrial Quick Start...

Page 5: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 5 18 Wall Mounting 1 USW Industrial Quick Start Guide ...

Page 6: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 6 18 2 USW Industrial Quick Start Guide ...

Page 7: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 7 18 3 USW Industrial Quick Start Guide ...

Page 8: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 8 18 4 USW Industrial Quick Start Guide ...

Page 9: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 9 18 Connecting Power USW Industrial Quick Start Guide ...

Page 10: ...9 9 2019 USW Industrial Quick Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 10 18 Connecting Ethernet 1 USW Industrial Quick Start Guide ...

Page 11: ... com download unifi and follow the on screen instructions Note If you already have UniFi Controller v5 10 x or newer installed skip to Adopting the UniFi Switch After you have installed the software and run the UniFi Installation Wizard a login screen will appear for the UniFi Controller management interface Enter the admin name and password that you created and click Sign In USW Industrial Quick ...

Page 12: ...g the UniFi Controller management interface To adopt the UniFi Switch proceed to Adopting the UniFi Switch For information on configuring and using the UniFi Controller software refer to the User Guide on the website ui com download unifi Adopting the UniFi Switch 1 From the UniFi Controller dashboard click Devices in the left menu bar USW Industrial Quick Start Guide ...

Page 13: ... Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 13 18 2 On the Devices screen locate the UniFi Switch in the list of devices under the Model column To adopt the UniFi Switch click Adopt USW Industrial Quick Start Guide ...

Page 14: ...turn blue to confirm that it has been successfully adopted Specifications USW Industrial Dimensions 254 x 235 x 60 mm 10 x 9 25 x 2 36 Weight 3 85 kg 8 49 lb Interfaces Networking 8 10 100 1000 802 3bt PoE RJ45 Ports 2 10 100 1000 RJ45 Ports Management Ethernet In Band Power Method 100 240 VAC 50 60 Hz Universal Input USW Industrial Quick Start Guide ...

Page 15: ... 450W 40 to 50 C 40 to 122 F Internal AC DC 240W 40 to 60 C 40 to 140 F Operating Humidity 5 to 95 Noncondensing Certifications CE FCC IC Safety Notices 1 Read follow and keep these instructions 2 Heed all warnings 3 Only use attachments accessories specified by the manufacturer WARNING Failure to provide proper ventilation may cause fire hazard Keep at least 20 mm of clearance next to the ventila...

Page 16: ...nded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The equipment requires the use of the ground wire as a part of the safety certification modification or misuse can provide a shock hazard that can result in serious injury or death c ...

Page 17: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is lik...

Page 18: ...k Start Guide https dl ubnt com qsg USW Industrial USW Industrial_EN html 18 18 RoHS WEEE Compliance Statement Declaration of Conformity Online Resources 2016 2019 Ubiquiti Inc All rights reserved USW Industrial Quick Start Guide ...