Ubert RT Series User Manual Download Page 23

Maintenance 

23 

printed: 03/2012  Subject to change! 

 

<

 RTUserManual.doc 

rectly on the cleaning rag and wipe it off this way. With this method it is possible to 
clean the Rotisserie Wall of Flame easily and without stripes.. 

6.1.5  Daily Cleaning 

1.  Make sure that the unit is cooled down bevor you start the cleaning procedure! 

2.  Unplug the unit. 

3.  Close the main gas supply. 

 

4.  Take out all removable Parts of the unit: 

·

  Open the glasdoors (optional). 

·

  Remove all remaining spits and/or baskets. 

·

  Empty the drip tray: 

·

  Put a suitable container below the discharge valve. 

·

  Open the discharge valve. 

·

  Discharge all liquid into the container and dispose it appropriate. 

·

  Remove the rest. 

·

  Remove the drip tray. 

·

  Remove the reflector sheets between the burners. 

5.  Clean all removable parts with a suitable detergent. Dry all parts. 

6.  Clean all parts of the rotisserie with a suitable detergent. Dry all parts. 

7.  Clean the gall doors (optional) with a soft cloth. Avoid scratching of the glas doors. 

 
Make sure, that no water/grease residues reach the burners or temperatur probes. 

 

 

Summary of Contents for RT Series

Page 1: ...User Manual Infrared Rotisserie RT Series...

Page 2: ......

Page 3: ...2 5 Special safety notes for the user 6 3 Product information 8 3 1 Introduction 8 3 2 Special Features 8 3 3 Technical Data 9 4 Initial Installation Procedure 14 4 1 Unpacking 14 4 2 Installation 14...

Page 4: ...nce hereby confirm the following That they know about the basic safety instructions and do know the regulations how to prevent possible accidents That they have read the safety chapter and warnings in...

Page 5: ...regular maintenance of any parts being subject to wear and tear In case of nonprofessional service In case of any force majeure 2 3 Explaination of Symbols and notes for the user Within this operatio...

Page 6: ...teps These operating instructions shoud be kept always together with the appliance Supplementing to the operation instructions within this manual all local regulations for accident prevention and for...

Page 7: ...ng and repairing is performed Make sure that all loose screw connections are fixed and secured again Check all safety devices and their proper function carefully at the end of all mainte nance service...

Page 8: ...ce available and where a reliable large capacity is required Built with a compact design the Infrared Rotisserie allows a capacity of up to 90 chicken or equivalent food products within 2 m A user fri...

Page 9: ...00mm RT3G 3 1280mm 700mm 700mm 876mm 100mm RT33G 5 1280mm 700mm 700mm 876mm 100mm RT4G 4 1280mm 700mm 865mm 1041mm 100mm RT44G 7 1280mm 700mm 865mm 1041mm 100mm RT5G 5 1280mm 700mm 1030mm 1206mm 100mm...

Page 10: ...0Hz 0 03kW RT5G R 25kW 230V 1 N 50Hz 0 03kW RT55G R 25kW 230V 1 N 50Hz 0 03kW RT6G R 30kW 230V 1 N 50Hz 0 03kW RT66G R 30kW 230V 1 N 50Hz 0 03kW RT7G R 35kW 230V 1 N 50Hz 0 03kW RT77G R 35kW 230V 1 N...

Page 11: ...190 open fixed 2 5 RT4 44G 20 14 3 Propane 4 95 95 fixed 2 5 RT4 44G 20 14 3 Natural H 4 165 open fixed 2 5 RT4 44G 20 14 3 Natural L 4 190 open fixed 2 5 RT5 55G 25 17 9 Propane 5 95 95 fixed 2 5 RT5...

Page 12: ...22G Propane 0 78 RT2 22G Natural H 1 06 RT2 22G Natural L 1 23 RT3 33G Propane 1 17 RT3 33G Natural H 1 59 RT3 33G Natural L 1 85 RT4 44G Propane 1 56 RT4 44G Natural H 2 12 RT4 44G Natural L 2 46 RT5...

Page 13: ...3 3 7 The units correspond to kind of construction B11 The type plate is fixed on the front side of the unit and bears the following indications Serial number type Order number kind of construction ac...

Page 14: ...r things which could block the slots Take care that the area around the rotisserie is free in order to load unload clean the unit or that maintenance works can be done smoothly The unit has to be set...

Page 15: ...i cated kind of gas on the type plate with the existing kind of gas If this is not the case an adjustment according to the local requirements is necessary The gas connection depends on the rotisserie...

Page 16: ...ting kind of gas If you adjust the unit for other gas types please check the indication of the nozzles The nominal heat load re sults from using the right nozzle with connection pressure of 20 mbar wi...

Page 17: ...front of the unit 4 5 1 Replacement of main nozzle Close the main gas supply and unplug the unit Remove reflector sheet to get access to the tie rod at the back of the burner Unlock tie rod Remove bur...

Page 18: ...gas to escape Use a suitable lighter eg Ubert special gas lighter P N GAZ After succesfull ignition keep the knob pushed for 15 20 seconds After releasing the knob the burner is in maximum position Tu...

Page 19: ...ens nicht unkontrolliert hin und her bewegen Stecken Sie das H hnchen mit der Kopfseite voran auf den Grillspie F hren Sie den Vierkant stab des Spie es dabei durch das Loch an der Kopfseite in das H...

Page 20: ...auf den Grillspie und verfah ren Sie weiter wie oben beschrieben Stecken Sie die Fl gelenden dann in das Loch am Fu ende des vorherigen H hnchens fest Fixieren Sie die H hnchenreihe mit der Endklammer...

Page 21: ...3 2012 Subject to change RTUserManual doc 5 2 2 Use of baskets Legen Sie die H hnchen auf das Unterteil des Grillkorbes Stecken Sie das Oberteil des Grillkor bes auf das Unterteil und befestigen Sie d...

Page 22: ...s It is absolutely necessary to watch out for some fundamental things to keep this longliving high grade steel machine working always keep the high grade steel surface clean watch out that there is al...

Page 23: ...lasdoors optional Remove all remaining spits and or baskets Empty the drip tray Put a suitable container below the discharge valve Open the discharge valve Discharge all liquid into the container and...

Page 24: ...24 Maintenance printed 03 2012 Subject to change RTUserManual doc 6 2 Wiring Diagram 6 2 1 All Models 240V 50 60Hz 1 N...

Page 25: ...es will cause a loss of any warranty claims Also all certificates such as CE UL VDE GS and others will not be valid anymore 6 3 1 List of Spare Parts lamp socket 340412 halogen lamp 200W 340620 temper...

Page 26: ...switch 16A 341115 dial scale I O 360203 shockproof plug 341301 plug for motor female 341401 plug for motor male 341302 burner 190583 ceramic inlay large 350805 ceramic inlay small 350806 wire mesh 190...

Page 27: ...Maintenance 27 printed 03 2012 Subject to change RTUserManual doc 6 4 Declaration of Conformity...

Reviews: