TROUBLESHOOTING
Problem Cause
Solution
E1
Electrical short on both temperature
sensor and PCB
Contact Customer Service for
repair
E2
Electrical short of temperature sensor copper
tube and PCB wiring
Contact Customer Service for
repair
E3
Refrigerant leaking from the copper tube
Contact Customer Service for
repair
E4
Indicates water tank is full or drainage
plug is not positioned properly
Pull out the rubber stopper located
at the bottom of the unit, to drain
the water. Replace plug correctly
and start unit.
SPECIFICATIONS
Model No.
PC10-AMD
Power Source
120V~ 60Hz
Cooling Capacity
10,000 BTU/hr
Heating Capacity
10,000 BTU/hr
Refrigerant R410A
Dimensions (W x H x D)
12” x 31” x 20”
(30 x 77.8 x 50.5 cm)
(CE) N 842/2006:
R410A is a fluorinated greenhouse gas covered by the Kyoto Protocol.
Its total global warming potential (GWP) is 1975.
Please discard or recycle your product and its packaging
according to your municipal bylaws.
EXHAUST OF AIR OUTDOORS
(
OPTIONAL
)
1
.
Install the flexible exhaust hose and the adjustable window slider kit
as depicted in Fig.1
&
Fig.1a.
CONVERSION FROM COOLING TO
HEATING MODE
To convert unit from cooling to heating mode, please change the exhaust pipe as
follows:
1
.
Remove the outlet grille (fig.1) and replace with the exhaust pipe assembly (fig.2).
Insert exhaust pipe as indicated (Fig.3).