Uberhaus 87795021 Operator'S Manual Download Page 3

To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage.

Your air conditioner should be used in such a way

that it is protected from moisture. e.g. condensation,

splashed water, etc. Do not place or store your air

conditioner where it can fall or be pulled into water

or any other liquid. Unplug immediately.

Always transport your air conditioner in a vertical

position and stand on a stable, level surface during

use.

Turn off the product when not in use.

Always contact a qualified person to carry out

repairs. If the supply cord is damaged it must be

repaired by a qualified repairer.

Keep an air path of at least 1 ft (30 cm) all around the

unit from walls, furniture and curtains.

If the air conditioner is knocked over during use,

turn off the unit and unplug from the mains supply

immediately.

!

Always do this

Do not operate your air conditioner in a wet room

such as a bathroom or laundry room.

Do not touch the unit with wet or damp hands or

when barefoot.

Do not press the buttons on the control panel with

anything other than your fingers.

Do not remove any fixed covers. Never use this

appliance if it is not working properly, or if it has

been dropped or damaged.

Never use the plug to start and stop the unit.

Always use the switch on the control panel.

Do not cover or obsturct the inlet or outlet grilles.

Do not use hazardous chemicals to clean or come

into contact with the unit. Do not use the unit in the

presence of inflammable substances or vapours such

as alcohol, insecticides, petrol,etc.

Do not allow children to operate the unit

unsupervised.

Do not use this product for functions other than

those described in this instruction manual.

Never do this

Energy Saving Tips

Use the unit in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.

Keep the filters clean.

Keep doors and windows closed to keep cool air in and warm air out.

The air conditioner must be operated within the temperature range indicated below:

Operating conditions

Safety rules

Suggested tools for window kit installation

1. Screwdriver(medium size Phillips)

2. Tape measure or ruler

3. Knife or scissors

4. Saw (In the event that the window kit needs to be cut down in size because

the window is too narrow for direct installation)

MODE

OOM TEMPERATURE

COOL

DRY

HEAT(electrical heat type)

Note: Perform ance may be reduc ed outside of these operating temperatures.

2

SAFETY PRECAUTIONS

Summary of Contents for 87795021

Page 1: ...l and the original sales invoice in a safe dry place for future reference Notre personnel du service la client le est disponible pour vous aider En cas de probl me avec votre achat ou pour obtenir plu...

Page 2: ...SAFETY PRECAUTIONS IDENTIFICATION OF PARTS AIR CONDITIONER FEATURES OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE TROUBLESHOOTING TIPS WAR ANTY R TABLE OF CONTENTS The rating d...

Page 3: ...d covers Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cov...

Page 4: ...cle is accessible after the unit installation WARNI NG For your safety Do not store or use gasoline or other flammable vapoursand liquids in the vicinity of this or any other appliance Avoid fire haza...

Page 5: ...ndle both sides Remote signal receptor 1 2 3 4 Fig 1 Fig 2 Rear 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Bottom tray drain outlet Drain Outlet Air intake Air intake Lower Air Filter...

Page 6: ...collected water away If error repeats call for service Display panel communication Unit malfunction Unplug the unit and plug it back in If error repeats call for service Error codes E1 Room temperatur...

Page 7: ...buttons at the same time for 3 seconds FAN operation SLEEP operation The air conditioner will control the room temperature automatically to the temperature point set by you Under AUTO mode you can no...

Page 8: ...up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically rever...

Page 9: ...floor strong enough to support the unit The unit has casters for easier placement but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to ro...

Page 10: ...ace the window slider kit on the window sill Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window See Fig 10 4 Close the window sash securely against the...

Page 11: ...is less than 22 1 inches Open the window sash and place the window slider kit on the window sill See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the wind...

Page 12: ...T DO NOT OVER BEND THE DUCT SEE Fig Fig 17 Note Cover the hole using the adaptor cap when not in use Fig 16 COOL HEAT heat pump type or AUTO mode FAN DEHUMIDIIFY or HEAT electrical heat type mode Inst...

Page 13: ...tom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 23 Reinstall the bottom drain plug and restart the mach...

Page 14: ...he lower filter by using the screws see Fig 26 Removal Cleaning Mounting O O 2 Unit enclosure Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Dry enclosure with a clean...

Page 15: ...room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Air is not cool enough Place the unit on a flat level ground if possible This sound i...

Page 16: ...Model INSTRUCTIONS Celsius Scale C RG51B31 CE RG51B31 CE RG51B31 CE 15...

Page 17: ...12 10 11 12 SET TEMPERATURE O O O O display TEMP AUTO MODE TEMP C screen Model INSTRUCTIONS RG51B31 CE 16 NOTE While the unit is running under SLEEP mode it would be cancelled if ON OFF FAN SPEED SLEE...

Page 18: ...MODE TEMP NOTE MODE TEMP 3 1 2 controlled NOTE 4 3 1 2 MODE TEMP NOTE 3 1 2 TEMP AUTO MODE TEMP C TEMP AUTO MODE TEMP C TEMP AUTO MODE TEMP C INSTRUCTIONS 17...

Page 19: ...INSTRUCTIONS 18...

Page 20: ...INSTRUCTIONS 19 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated...

Page 21: ...he next o o 30 minutes and by another 1 C 2 F after an additional 30 minutes This new temperature will be maintained for 6 on some models 7 hours before it returns to the originally selected temperatu...

Page 22: ...air other than by an authorized agent Heavy duty daily professional or hire usage are not guaranteed RONA is not responsible for any costs related to labour injuries or any other loss incurred during...

Reviews: