15 ERP values
Technical information sheet Ubiflux Vigor W325 (Plus) in accordance with Ecodesign (ErP), no. 1254/2014 (Annex
IV)
Manufacturer:
Ubbink NV
Model:
Ubiflux Vigor W325 Plus
Climate
zone
Type of control
SEC Value in
kWh/m²/a
SEC
Class
Annual
electricity
consumption
(AEC) in kWh
Annual heating
saved (AHS) in
kWh
Average
manual
-40.99
A
233
4614
clock control
-41.59
A
215
4628
1x sensor (RV/CO
2
/VOC)
-42.72
A+
181
4657
2 or more sensors (RV/CO
2
/VOC)
-44.71
A+
124
4714
Cold
manual
-79.74
A+
770
9026
clock control
-80.48
A+
752
9054
1x sensor (RV/CO
2
/VOC)
-81.88
A+
718
9110
2 or more sensors (RV/CO
2
/VOC)
-84.42
A+
661
9222
Hot
manual
-16.17
E
188
2086
clock control
-16.69
E
170
2093
1x sensor (RV/CO
2
/VOC)
-17.66
E
136
2106
2 or more sensors (RV/CO
2
/VOC)
-19.33
E
79
2132
Type of ventilation unit:
Balanced residential ventilation appliance with heat recovery
Fan:
EC - fan with infinitely variable control
Type of heat exchanger:
Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency
91%
Maximum flow rate:
325m³/h
Maximum rated power:
145 W
Sound power level Lwa:
41 dB(A)
Reference flow rate:
228m³/h
Reference pressure:
50 Pa
Specific Power Input (SEL):
0.15 Wh/m³
Control factor:
1.0 in combination with multiple switch
0.95 in combination with clock control
0.85 in combination with 1 sensor
0.65 in combination with 2 or more sensors
Leakage*
Internal
2.85%
External
2.85%
Position dirty filter indication:
On the display of the appliance / on the multiple switch (LED) /
on the Air Control.
Attention!
For optimal energy efficiency and a proper
operation, a regular filter inspection, cleaning or replacement is
necessary.
Internet address for Assembly instructions:
http://www.ubbink.be
Bypass:
Yes, 100% Bypass
*
Measurements executed by TZWL according to the EN 13141-7 standard
Ubiflux Vigor W325 615743-G
Ubbink / 57