Operating instructions for Heatermax Compact 10 / 20 Swimming Pool Heat Pumps
1
14
Dear Customer,
We congratulate you on your purchase of the Heatermax Compact swimming pool heat pump. The Heatermax Compact heat pump warms up the water in your pool and keeps it at a constant temperature when
the outside temperature is between 12°C and 42°C. These operating instructions include all necessary information on installation, operation and maintenance of the swimming pool heat pump. Please read through
these operating instructions in detail and keep them carefully.
ATTENTION: The installer is responsible for the installation of the product and should follow all instructions related to the installation and maintenance of the device, as well as consider all
the applicable specifications.
Dimensions
Model
Heatermax Compact 10
Heatermax Compact 20
Article No.
7505503
7505504
Voltage / Frequency / Phase
220-240V ~ 50Hz / 1 Phase
Rated current
2,6 A
4,4 A
Recommended fuse protection
10 A
10 A
Mains cable
2.5 m / Plug with leakage current (Fi) protective circuit breaker
Protection class
I
I
Protection type
IP X4
IP X4
Heating capacity in case of Condition 1: Air 27°C / water 27°C/ humidity 80%
Heating power
2,50 kW
4,20 kW
Power consumption
0,59 kW
0,91 kW
Rate of performance (COP)
4,2
4,2
Heating capacity in case of Condition 2: Air 15°C / water 26°C / humidity 70%
Heating power
1,90 kW
3,20 kW
Power consumption
0,56 kW
0,91 kW
Rate of performance (COP)
3,9
3,5
Max. pool volume
10 m3
m3
Min. Water flow-through
2 m3/h
2 m3/h
Max. water pressure
15 kPa
15 kPa
Water temperature (operating range)
15°C - 35°C
Air temperature (operating range)
12°C - 42°C
Inlet / Outlet
38/32 mm
Compressor (type/brand)
Rotation/Mitsubishi
Rotation/Hitachi
Ventilation direction
Horizontal
Noise level at 1 m distance
57 dB(A)
55 dB(A)
Noise level at 10 m distance
48 dB(A)
46 dB(A)
Housing
Rust-free zinc-coated steel
Heat exchanger
Titanium (PVC container)
Cooling gas R32
150 g
280 g
GWP value
675
675
CO2 equivalent
0,19 t
0,10 t
Length
310 mm
434 mm
Width
356,5 mm
432,5 mm
Height
365 mm
460 mm
Net weight
18 kg
26 kg
Technical data
Model
A
B
C
D
E
F
G
Heatermax COMPACT 10
103mm
103mm
51mm
375mm
310mm
300mm 356.5mm
Heatermax COMPACT 20 132.5mm 168mm
50.7mm
460mm
434mm
371mm 432.5mm
Heatermax Compact 10 / 20 include fluorinated greenhouse gases. Right to changes reserved
Safety regulations
This device was built in accordance with the current state of the art of the technology and considering the existing safety regulations. In spite of this, dangers to persons and property can arise from this device
when it is used inappropriately or not in accordance with the intended purpose or the notes on safety are not considered.
ATTENTION! According to the harmonised European directives and safety standards, any installation, service and repair work on the device, as well as installation and/or maintenance of
the mains cable, must be implemented by an authorised and qualified specialist company. Before beginning with the installation, operation, service or maintenance work, the specialist
instructed with these tasks must have read and understood the operating instructions.
• The power supply must correspond to the product specifications. Do not connect the device if the power supply does not fulfil the specified specifications (VDE 0100-702)! You can be provided with further
information by your local, accredited electrical installer.
• The electrical circuit for the device must be fused over a residual-current device (FI or RCD) with a rated leakage current of max. 30 mA.
• The heat pump must be installed at a distance of minimum 2 m from the swimming pool.
• The electrical connection of the heat pump must be located minimum 3.5 m from the swimming pool.