Installation Procedures 

skySensor is a wingtip, forward, right position light. The assembly should be mounted 
as far outboard on the aircraft as practical, parallel to the vertical and horizontal 
centerlines of the aircraft. Ensure that when mounted, the fin and top of the assembly 
are free from obstructions. 
 
1.  Remove the existing right position light. 
2.  Detach the power wire(s). 
3.  Connect the red wire to the switched power wire.  
4.  skySensor is grounded to the aircraft structure via the mounting screws.    
     However, it may be necessary to connect the black wire to the airframe ground. 
5.  Mount skySensor using the three supplied 6-32 screws and o-rings.   
     See diagram page 3 
Changes to the existing position light circuit breaker rating are not required. 

 

 
 
 
 
 
 
 
 
 
 
 
Connecting an Electronic Flight Bag 

1.  Apply power to skySensor by turning the position lights on. 
2.  Connect your wireless device to the skySensor SSID. 
3.  Once connected follow the instructions for your electronic flight bag application. 
4.  Traffic, weather and GPS data will be available to the application. 

Applications supporting GDL90 

 
 
 

 
 
 
 
 

Wiring Considerations 

Connect the red wire to the switched power wire.  
 
Connecting the black wire to the aircraft structure should be suitable but 
it may be necessary to connect the black wire to the battery ground in 
some cases. 
 
Connect the yellow wire to the strobe switch. The strobe high voltage 
power supply must be bypassed for the skyBeacon.   Connecting 
skyBeacon to the HV strobe power supply will damage the device.    

Summary of Contents for skySensor

Page 1: ...e MOPs of DO 260B and DO 282B Position Light Meets performance requirements of TSO C30c Type I Static Pressure Integrated precision temperature controlled static pressure sensor accurate to 80 000ft GPS Integrated RAIM processor for Security and Integrity protection SBAS corrections and health messages used to detect and correct satellite range errors Satellite pseudo range step errors detected an...

Page 2: ...raft structure via the mounting screws However it may be necessary to connect the black wire to the airframe ground 5 Mount skySensor using the three supplied 6 32 screws and o rings See diagram page 3 Changes to the existing position light circuit breaker rating are not required Connecting an Electronic Flight Bag 1 Apply power to skySensor by turning the position lights on 2 Connect your wireles...

Page 3: ...__________________________________________________________________ uAvionix reserves the right to alter product services offerings specifications and pricing at any time without notice Copyright 2017 uAvionix All rights reserved www uavionix com UAV 1001479 001 Installation Diagram Mounting template 1 1 scale ...

Page 4: ...cks 7 2 Equipment tested to Category B Crash Safety 7 3 Equipment tested to Category B type 5 Vibration 8 0 Aircraft zone 2 type 3 4 5 to Category S level M type 1 Helicopters to Category U level G Explosion 9 0 Equipment identified as Category X no test Waterproofness 10 0 Equipment identified as Category X no test Fluids Susceptibility 11 0 Equipment identified as Category X no test Sand and Dus...

Reviews: