background image

 
 
 

 

 
 

 

OWNER’S MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 

COMMERCIAL ELECTROSTATIC AIR CLEANER 

 

 MODEL: 

SE 24  

 

 

Summary of Contents for Smokeeter SE 24

Page 1: ...OWNER S MANUAL COMMERCIAL ELECTROSTATIC AIR CLEANER MODEL SE 24 ...

Page 2: ......

Page 3: ...ION 740 Watts max AIR HANDLING CAPACITY Low Setting 350 875 CFM High Setting 390 1 020 CFM Factory preset for Low Setting Operation WEIGHT HANGING 118 lbs 53 5 KG SHIPPING 130 lbs 59 0 KG DIMENSIONS Height Length Width 17 465 8 227 8 43 2 cm 118 4 cm 58 1 cm MODEL SE 24 SPECIFICATIONS Nominal CFM ...

Page 4: ...LLOWING INFORMATION IS PROVIDED FOR TRAINED SERVICE PERSONNEL ONLY VII Periodic Maintenance and Troubleshooting 9 VIll Replacement Parts 11 IX Illustrated Parts 13 Wiring Diagram 18 IMPORTANT NOTICE BEFORE OPERATION PLEASE REMOVE ALL PACKING MATERIAL FROM INSIDE UNIT THIS CAN INCLUDE MARKED TIE DOWN SCREWS CARDBOARD STYROFOAM AND PLASTIC WRAP ON CARBON FILTER MODELS VARY IN MATERIAL USED ...

Page 5: ...rate at peak efficiency for many years Finally while we hope you never have any problems United Air Specialists Inc UAS is always ready to lend assistance We have factory trained distributors world wide Should you need information or service contact your local distributor or the Technical Support Dept at United Air Specialists Inc 4440 Creek Road Cincinnati Ohio 45242 1 800 252 4647 II INSPECTION ...

Page 6: ...ries of con voluted metal plates These plates act like a magnet and attract the charged particles removing them from the air The plates are alternately charged pos itive and ground The positive plates repel the par ticles while the ground plates attract them yielding a very high efficiency 4 OPTIONAL ACTIVATED CARBON AFTERFILTER Aids in removing odors from the air 5 POWER PACK Is a dual high volta...

Page 7: ...g replacing a 2 x 4 ceiling tile Remove ceiling tile where unit is to be installed Check location to ensure there is a minimum of 171 2 clearance above the ceiling tile Additional tiles adja cent to where the unit will be located should be remov ed to facilitate installation The Installation Parts Kit 03 0569 contains the following Part Item Quantity 10 2348 Hanging wire 12 ga 18 ft 10 2452 Corner...

Page 8: ...it and secure in approximate position Install four corner locating plates Attach with 8 screws Check alignment and gaps Each end should be the same distance to the T bar The hinge side should align flush with the T bar and be about 1 16 to 1 8 above the T bar For best results this gap should be constant along the T bar ...

Page 9: ... After alignment is complete secure fasteners If hanging wire supplied by UAS is used to support the unit wrap a minimum of five turns Install carbon filter after removing plastic bag Install unicell prefilter Attach high voltage leads to cell and ionizer and gently press speed control knob on shaft ...

Page 10: ...g 115V 1 60 lighting circuits so that the unit will be on whenever the lights are on The electrical branch should be checked to see that it will handle the additional load of the unit which draws 6 4 am peres and is 115 volts single phase 60 HZ 2 The unit can be run to a discrete wall switch to pro vide more convenient control This switch will pro vide on and off functions only Speed setting will ...

Page 11: ...its purpose Periodic cleaning is necessary to maintain efficiency and is confined to the unicell and mesh filter A regular cleaning schedule is suggested Frequency of cleaning depends upon the concentration and type of con taminants Your local distributor will be able to help you set up a schedule based on your requirements If a distributor is not available in your area please contact United Air S...

Page 12: ...ot water Shake off excess water and let components dry for 30 60 minutes Set the unicell so that its plates are in a vertical position for drainage Do not reinstall the unicell until it is thor oughly dry Vacuum the interior of the cabinet to remove any loose lint or dust that may have accumulated Clean the faceplate grille by wiping down with a lint free soft cloth and a suitable household cleane...

Page 13: ...tion consists of plates alternately charged with a nominal 5 500 volts DC positive and ground The field between the plates forces the charged particles to the ground plates and removes them from the airstream 4 Carbon Filter aids in odor removal 5 Motor Blower draws in contaminated air and discharges the clean air back to the room HOW THE HIGH VOLTAGE IS SUPPLIED TO THE COMPONENTS The power pack s...

Page 14: ...R VOLTAGE 1 Connect the ground clip of the positive polarity probe to the side of the cabinet 2 Engage the safety interlock switch and measure the collector high voltage by placing the probe s tip on the cell contact stud The voltage reading should be 4 0 to 6 0 KV DC If measurements are abnormal refer to the trouble shooting guide for cause and correction CHECKING THE POWER PACK OUTPUT 1 Remove t...

Page 15: ...ges disconnect the lead black wire coming from the wire box plug from the motor red wire and connect to the motor black wire See wiring diagram located on the unit VIII REPLACEMENT PARTS Any replacement parts can be ordered from your local distributor Should you need any further assistance call or write UNITED AIR SPECIALISTS INC 4440 CREEK ROAD CINCINNATI OHIO 45242 TEL 513 891 0400 800 252 4647 ...

Page 16: ...engaged 3 Safety interlock switch 3 Replace safety defective interlock switch 4 Control switch defective 4 Replace control switch D Motor operates on 1 Control switch defective 1 Replace control switch one speed only E Poor air quality 1 Unicell dirty 1 Clean unicell 2 Unicell malfunctioning 2 Check unicell for a Foreign matter between plates b Ionizer wire loose or broken c Defective insulators 3...

Page 17: ...13 IX ILLUSTRATED PARTS ...

Page 18: ...UIDE BLOCK 2 6 30 0316 RIVET 8 8 20 1379 JUNCTION BOX 1 9 20 1380 JUNCTION BOX COVER 1 10 21 1218 POWER PACK GREY PLASTIC CONSTRUCTION 1 11 30 0076 SCR HEX HD GREEN 10 32 x 3 8 LG 1 12 33 0124 AFTERFILTER CARBON 1 13 33 0125 PREFILTER ALUM MESH 1 14 42 0168 GASKET EDGE 1 5 ft 20 0290 CABLE TIE MOUNTING DEVICE 4 02 2597 WIRE HARNESS SE 24 1 42 0153 GASKET EPDM 3 16 x 1 1 12 2 ft 30 0479 SCREW 12 x ...

Page 19: ...2 LONG 4 3 37 0008 PVC CELL INSULATOR 8 4 36 0004 IONIZER WIRE SUPPORT SPRINGS 12 5 18 0709 IONIZER WIRE SUPPORT BAR 2 8 10 0158 CELL PLATE GROUND 18 9 10 0157 CELL PLATE HOT 24 10 10 1376 CELL PLATE IONIZER 5 12 10 1372 UNICELL END PLATE 2 13 30 0163 RETAINER CLIP 1 14 30 0165 RETAINER 1 15 35 0067 SPACER 188 16 30 0350 NUT ACORN 1 4 20 2 ...

Page 20: ...T 1 5 30 001 6 SCR RND HD 6 32 x 1 LG 2 6 30 0038 6 INTERNAL TOOTH LOCKWASHER 2 6 30 0001 6 32 HEX NUT 2 7 39 0097 KNOB 1 8 41 0280 LABEL INTERLOCK ENG FRENCH 1 9 41 1 040 LABEL WIRING DIAGRAM 1 10 41 1 039 LABEL CONTROL PLATE 1 12 02 31 24 H V LEADS ASSEMBLY SE 24 1 14 20 1244 STRAIN RELIEF 1 21 1218 POWER PACK 1 30 0065 1 4 FLAT WASHER 2 30 0500 1 4 LOCK NUT 2 NOT SHOWN SEE PAGES 14 AND 15 ...

Page 21: ...PTION QUANTITY 1 32 0149 BLOWER SE 24 1 2 02 2352 MOTOR ASSEMBLY 1 3 20 0569 CAPACITOR 1 5 30 0049 FLATWASHER 1 4 3 6 30 0233 BOLT HEX HD 1 4 20 x 1 3 7 41 0065 LABEL ROTATION 1 8 20 0290 WIRE TIE MOUNT 2 9 20 0138 WIRE TIE 2 10 30 0335 DRILL SCREW 8 32 x 1 2 2 ...

Page 22: ...18 WIRING DIAGRAM ...

Page 23: ......

Page 24: ...or normal wear and tear This warranty will be void with respect to equipment that is subject to unauthorized repairs or modifications UAS makes no warranty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUS...

Reviews: