SAFETY PRECAUTIONS

We have provided many important safety messages in this manual and on the MCB unit. Always read and obey all safety 

messages.

•  Use two or more people to move and install the 

 

MCB system.

• The air cleaner must be properly grounded.
• Disconnect power before servicing.
• Replace all access panels before operating.
•  Wear protective clothing and safety glasses when handling 

collection components or servicing the air cleaner.

•  Electrical connections should only be made by qualified 

 

personnel, and be in accordance with local and national 

codes and regulations.

• Do not use in explosive atmospheres.

• Use nonflammable cleaners.
• Do not collect emissions which are explosive.
•  Keep flammable materials and vapors, such as gasoline, 

away from air cleaner.

•  The unit should be inspected frequently and dirt removed 

to prevent excessive accumulation which may result in 

flash-over or fire damage.

•  The MCB system should not be used for 

 

support of personnel or material.

• Operate only in safe and serviceable condition.

!

 

 

!

   

D A N G E R

!

 

WARNING

!

 

 C A U T I O N

C A U T I O N

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.  All safety messages will follow the 

safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words mean:

Indicates a hazardous situation which, if not avoided, will result in death or 

serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result 

in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result 

in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially 

hazardous situation which, if not avoided, may result in property damage.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of fire, electric shock, or injury when using the air cleaner, follow these basic precautions:

!

 

WARNING

Summary of Contents for CLARCOR MCB Series

Page 1: ...Cross Ventilation Cartridge Dust Collector l MCB Series OWNER S MANUAL...

Page 2: ...ation available when contacting UAS UAS ORDER __________________________________________________________ UNIT MODEL _ ________________________________________________________ UNIT SERIAL _ ___________...

Page 3: ...5 1 1 Digital Pulse Monitor DPM Panel Installation 10 5 1 2 Digital Pulse Control DPC Panel Installation 10 5 1 3 Final Connections For All Gauge Options 10 5 2 Electrical Connections For Booth Lights...

Page 4: ...ccumulation which may result in flash over or fire damage The MCB system should not be used for support of personnel or material Operate only in safe and serviceable condition DANGER WARNING CAUTION C...

Page 5: ...aning in the work environment or as part of your manufacturing process As you review this manual refer to Figure 1 and 2 for assistance in locating unit parts 2 3 AIR FILTERING OPERATION During the ai...

Page 6: ...2 Revised 03 15 MCB Crossflow Dust Collector Figure 1 MCB Operation Detail 44 10343 0001...

Page 7: ...3 Revised 03 15 MCB Crossflow Dust Collector Figure 2 Typical MCB Dust Collector With Booth Enclosure Installation 44 10344 0003...

Page 8: ...to be installed the modules need to be spaced with a 1 gap between side panels A UAS supplied trim strip will bridge the gap between the units 3 To install the trim strip remove all fasteners on the f...

Page 9: ...5 Revised 03 15 MCB Crossflow Dust Collector Figure 3 MCB Installation Detail 44 10360 0001...

Page 10: ...wall bracket only has one See Figure 5 2 On the inlet side of all modules remove the top row of fasteners excluding the ones holding the trim strip in place Locate the top panel support bracket using...

Page 11: ...7 Revised 03 15 MCB Crossflow Dust Collector Figure 4 Motor Installation Diagram 44 10342 0001...

Page 12: ...8 Revised 03 15 MCB Crossflow Dust Collector Figure 5 MCB Booth Assembly 44 10361 0001...

Page 13: ...9 Revised 03 15 MCB Crossflow Dust Collector Figure 6 Booth Panel Interlock Connection...

Page 14: ...l DPC panel remove it from the box Instructions for mounting and connecting the panel are available in the DPM DPC Installation and Owner s Manual The panel should be installed within close proximity...

Page 15: ...11 Revised 03 15 MCB Crossflow Dust Collector Figure 7 MCB Pressure Gauge Installation 44 10350 0001...

Page 16: ...a pulse If the delivery capability of your compressed air source cannot return the manifold pressure to above 90 PSIG during the Pulse Delay factory set at 10 sec interval adjust the pulse delay at th...

Page 17: ...13 Revised 03 15 MCB Crossflow Dust Collector Figure 8 Solenoid Wiring to Pulse Controls 61 10017 0001 REV B...

Page 18: ...g grease The recommended grease is Chevron SRI 2 Periodically inspect the fan wheel coupling mounting bolts for tightness Re tighten as necessary to ensure the fan wheel does not loosen and come in co...

Page 19: ...excessive pressure drop over 5 on filter monitor panel Compressed air supply problems Check incoming compressed air for proper pressure 90 110 PSIG 6 4 7 2 BAR pulse flow 1 7 SCF standard cubic feet...

Page 20: ...16 Revised 03 15 MCB Crossflow Dust Collector 9 ILLUSTRATED PARTS 6 and 9 Foot Wide Module...

Page 21: ...R BOARD Not Shown SOLENOID ENCLOSURE 4 POSITION SOLENOID ENCLOSURE 6 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown LIGHTING FIXTURE 2 BULB FLUORESCENT FINISHING PLUG 2 1...

Page 22: ...18 Revised 03 15 MCB Crossflow Dust Collector 11 ILLUSTRATED PARTS 3 Foot Wide Module...

Page 23: ...SURE 2 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown FINISHING PLUG 2 1 4 DIA SCREW HEX WASHER 5 16 18 x 3 4 LG SWAGEFORM BLOWER WHEEL BLOWER INLET CONE CARTRIDGE FILTER...

Page 24: ...uthorized repairs or modifications UAS makes no warranty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a...

Reviews: