4
Revised 03/15
MCB
Crossflow Dust Collector
3. SPECIFICATION TABLE
MCB 3 Foot Modules
MCB 6 Foot Modules
MCB 9 Foot Modules
4. INSTALLATION
4.1 OFF LOADING AND INSPECTION
UAS recommends using a forklift during unloading,
assembly and installation of the MCB dust collector.
A crane can be used for the individual modules.
Lifting lugs have been provided for each module.
Upon receipt of your unit, check for any shipping damage.
A damaged carton indicates that the equipment may have
received rough handling during shipping that may have
caused possible internal damage. Notify your delivery
carrier and enter a claim if any damage is found.
4.2 INSTALLATION PLANNING
For best installation and operation results, the MCB
booth should be installed on a flat concrete foundation
inside the factory. If the surface is not flat, modules and
booth walls must be shimmed to align bolt holes.
When calculating for the foundation, the weight of the
dust collector, material collected, MCB, booth and all
auxiliary equipment must be considered together for
seismic loads. Refer to individual specification drawing
for the MCB weight.
Choose the collector module location with consideration
for access to the dust collector, access to the dust
storage drawers located inside each module, creation
of the shortest run for electrical and air connections,
and ease of maintenance. If hazardous dust is involved,
consult local authorities for the best location for
the unit.
4.3 MODULE INSTALLATION
Each module comes in a 3’, 6’ or 9’ module width and
can be installed on either end or center interchangeably.
The booth assembly builds upon the modules,
therefore, it is important to locate the modules on a flat
surface. Refer to Figure 3 for assistance for both the
module and compressed air connection.
1. Position one of the modules as an "end unit" with
the inlet louver side facing the inside of the booth.
No rear or side access is required for the MCB dust
collector so the modules can be placed with the rear
or side against a wall if necessary.
2. If multiple modules are to be installed, the modules
need to be spaced with a 1" gap between side
panels. A UAS supplied trim strip will bridge
the gap between the units.
3. To install the trim strip, remove all fasteners
on the front panel of the adjoining corner from
both cabinets. Locate the trim strip so as to
match the cabinet bolt pattern and re-fasten
the screws. Repeat as necessary for
additional modules.
4.3.1 COMPRESSED AIR CONNECTION
1. Each MCB dust collector comes with four possible
compressed air supply points: two on the air inlet
side and two on the side panels of each module.
Each cabinet connection point is covered with a
removable finishing plug. To remove the plugs,
remove the front access panel and simply tap the
plugs out from the inside of the cabinet.
!
WA R N I N G
For lifting slings, use spreader bars and clevises, not hooks. Do not
lift the unit from any point other than the lifting lugs. Connect the
lifting sling to the four cabinet lifting lugs to distribute the load equally.
!
WA R N I N G
MCB dust collectors are not designed as explosion proof and/
or spark resistant units. Do not locate dust collector near dust
source in cases where the dust is explosive or a fire hazard.
Unit
CFM
# Filters Total sq. ft.
of Media
Face
Velocity ft/m
Booth Size
W’xH’xD’
MCB-06-01-H
9,000
8
2,720
200
150
200
150
200
150
150
200
6x7.5x8
6x7.5x8
12x7.5x8
12x7.5x8
18x7.5x8
18x7.5x8
24x7.5x8
24x7.5x8
6,750
8
2,720
5,440
5,440
8,160
8,160
10,880
10,880
18,000
16
13,500
16
627,000
24
20,250
24
36,000
36
27,000
36
MCB-06-01-S
MCB-12-02-H
MCB-12-02-S
MCB-18-03-H
MCB-18-03-S
MCB-24-04-H
MCB-24-04-S
Unit
CFM
# Filters Total sq. ft.
of Media
Face
Velocity ft/m
Booth Size
W’xH’xD’
MCB-09-10-H
13,500
12
4,080
200
150
200
150
200
150
150
200
9x7.5x8
9x7.5x8
18x7.5x8
18x7.5x8
27x7.5x8
27x7.5x8
36x7.5x8
36x7.5x8
10,125
12
4,080
8,160
8,160
12,240
12,240
16,320
16,320
27,000
24
20,250
24
40,500
36
30,375
36
54,000
48
40,500
48
MCB-09-10-S
MCB-18-20-H
MCB-18-20-S
MCB-27-30-H
MCB-27-30-S
MCB-36-40-H
MCB-36-40-S
!
C A U T I O N
Shut off and slowly release the pressure in the compressed
air piping and/or the MCB compressed air reservoir
manifold prior to servicing this equipment.
Unit
CFM
# Filters Total sq. ft.
of Media
Face
Velocity ft/m
MCB-03
4,500
4
1,360
200
Summary of Contents for CLARCOR MCB 06-01-S
Page 1: ...Cross Ventilation Cartridge Dust Collector l MCB Series OWNER S MANUAL ...
Page 6: ...2 Revised 03 15 MCB Crossflow Dust Collector Figure 1 MCB Operation Detail 44 10343 0001 ...
Page 9: ...5 Revised 03 15 MCB Crossflow Dust Collector Figure 3 MCB Installation Detail 44 10360 0001 ...
Page 12: ...8 Revised 03 15 MCB Crossflow Dust Collector Figure 5 MCB Booth Assembly 44 10361 0001 ...
Page 13: ...9 Revised 03 15 MCB Crossflow Dust Collector Figure 6 Booth Panel Interlock Connection ...
Page 20: ...16 Revised 03 15 MCB Crossflow Dust Collector 9 ILLUSTRATED PARTS 6 and 9 Foot Wide Module ...
Page 22: ...18 Revised 03 15 MCB Crossflow Dust Collector 11 ILLUSTRATED PARTS 3 Foot Wide Module ...