background image

4

Revised 03/15

MCB

Crossflow Dust Collector

3.  SPECIFICATION TABLE

MCB 3 Foot Modules

MCB 6 Foot Modules

MCB 9 Foot Modules

4.  INSTALLATION

4.1 OFF LOADING AND INSPECTION

UAS recommends using a forklift during unloading, 

assembly and installation of the MCB dust collector.  

A crane can be used for the individual modules.  

Lifting lugs have been provided for each module.

Upon receipt of your unit, check for any shipping damage. 

A damaged carton indicates that the equipment may have 

received rough handling during shipping that may have 

caused possible internal damage. Notify your delivery 

carrier and enter a claim if any damage is found.

4.2 INSTALLATION PLANNING

For best installation and operation results, the MCB 

booth should be installed on a flat concrete foundation 

inside the factory. If the surface is not flat, modules and 

booth walls must be shimmed to align bolt holes.
When calculating for the foundation, the weight of the 

dust collector, material collected, MCB, booth and all 

auxiliary equipment must be considered together for 

seismic loads. Refer to individual specification drawing 

for the MCB weight.
Choose the collector module location with consideration 

for access to the dust collector, access to the dust 

storage drawers located inside each module, creation  

of the shortest run for electrical and air connections, 

and ease of maintenance. If hazardous dust is involved, 

consult local authorities for the best location for  

the unit.

4.3 MODULE INSTALLATION

Each module comes in a 3’, 6’ or 9’ module width and 

can be installed on either end or center interchangeably.  

The booth assembly builds upon the modules, 

therefore, it is important to locate the modules on a flat 

surface.  Refer to Figure 3 for assistance for both the 

module and compressed air connection.
1.  Position one of the modules as an "end unit" with  

the inlet louver side facing the inside of the booth.  

No rear or side access is required for the MCB dust 

collector so the modules can be placed with the rear 

or side against a wall if necessary.

2.  If multiple modules are to be installed, the modules 

need to be spaced with a 1" gap between side 

panels.  A UAS supplied trim strip will bridge  

the gap between the units.  

3.  To install the trim strip, remove all fasteners  

on the front panel of the adjoining corner from  

both cabinets.  Locate the trim strip so as to  

match the cabinet bolt pattern and re-fasten  

the screws.  Repeat as necessary for  

additional modules.

4.3.1 COMPRESSED AIR CONNECTION

1.  Each MCB dust collector comes with four possible 

compressed air supply points: two on the air inlet 

side and two on the side panels of each module.  

Each cabinet connection point is covered with a 

removable finishing plug.  To remove the plugs, 

remove the front access panel and simply tap the 

plugs out from the inside of the cabinet.

 

!

  WA R N I N G

For lifting slings, use spreader bars and clevises, not hooks. Do not 

lift the unit from any point other than the lifting lugs. Connect the 

lifting sling to the four cabinet lifting lugs to distribute the load equally.

 

!

  WA R N I N G

MCB dust collectors are not designed as explosion proof and/

or spark resistant units. Do not locate dust collector near dust 

source in cases where the dust is explosive or a fire hazard.

Unit

CFM

# Filters Total sq. ft.

of Media

Face

Velocity ft/m

Booth Size

W’xH’xD’

MCB-06-01-H

9,000

8

2,720

200
150
200
150
200
150

150

200

6x7.5x8
6x7.5x8

12x7.5x8
12x7.5x8
18x7.5x8
18x7.5x8
24x7.5x8
24x7.5x8

6,750

8

2,720
5,440
5,440
8,160
8,160

10,880
10,880

18,000

16

13,500

16

627,000

24

20,250

24

36,000

36

27,000

36

MCB-06-01-S
MCB-12-02-H
MCB-12-02-S
MCB-18-03-H
MCB-18-03-S
MCB-24-04-H
MCB-24-04-S

Unit

CFM

# Filters Total sq. ft.

of Media

Face

Velocity ft/m

Booth Size

W’xH’xD’

MCB-09-10-H

13,500

12

4,080

200
150
200
150
200
150

150

200

9x7.5x8
9x7.5x8

18x7.5x8
18x7.5x8
27x7.5x8
27x7.5x8
36x7.5x8
36x7.5x8

10,125

12

4,080
8,160
8,160

12,240
12,240
16,320
16,320

27,000

24

20,250

24

40,500

36

30,375

36

54,000

48

40,500

48

MCB-09-10-S
MCB-18-20-H
MCB-18-20-S
MCB-27-30-H
MCB-27-30-S
MCB-36-40-H
MCB-36-40-S

 

!

  C A U T I O N

Shut off and slowly release the pressure in the compressed 

air piping and/or the MCB compressed air reservoir 

manifold prior to servicing this equipment.

Unit

CFM

# Filters Total sq. ft.

of Media

Face

Velocity ft/m

MCB-03

4,500

4

1,360

200

Summary of Contents for CLARCOR MCB 06-01-S

Page 1: ...Cross Ventilation Cartridge Dust Collector l MCB Series OWNER S MANUAL ...

Page 2: ...mation available when contacting UAS UAS ORDER __________________________________________________________ UNIT MODEL _ ________________________________________________________ UNIT SERIAL _ ________________________________________________________ CARTRIDGE FILTER PART ______________________________________________ SYSTEM ACCESSORIES _________________________________________________________________...

Page 3: ... 5 1 1 Digital Pulse Monitor DPM Panel Installation 10 5 1 2 Digital Pulse Control DPC Panel Installation 10 5 1 3 Final Connections For All Gauge Options 10 5 2 Electrical Connections For Booth Lights 10 5 3 Solenoid Valve Enclosure Wiring 10 6 OPERATION 10 6 1 Start Up 10 6 2 Operating Adjustments 12 6 2 1 Digital Pulse Monitor Panel DPM 12 6 2 2 Digital Pulse Control Panel DPC 12 7 SERVICE 12 7...

Page 4: ...accumulation which may result in flash over or fire damage The MCB system should not be used for support of personnel or material Operate only in safe and serviceable condition DANGER WARNING CAUTION C A U T I O N This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and the word DANG...

Page 5: ...eaning in the work environment or as part of your manufacturing process As you review this manual refer to Figure 1 and 2 for assistance in locating unit parts 2 3 AIR FILTERING OPERATION During the air filtering operation contaminated air enters the Mcb dust collector through the door louvers The inlet louvers allows heavier particles to fall into the dust storage drawer The contaminated air then...

Page 6: ...2 Revised 03 15 MCB Crossflow Dust Collector Figure 1 MCB Operation Detail 44 10343 0001 ...

Page 7: ...3 Revised 03 15 MCB Crossflow Dust Collector Figure 2 Typical MCB Dust Collector With Booth Enclosure Installation 44 10344 0003 ...

Page 8: ... to be installed the modules need to be spaced with a 1 gap between side panels A UAS supplied trim strip will bridge the gap between the units 3 To install the trim strip remove all fasteners on the front panel of the adjoining corner from both cabinets Locate the trim strip so as to match the cabinet bolt pattern and re fasten the screws Repeat as necessary for additional modules 4 3 1 Compresse...

Page 9: ...5 Revised 03 15 MCB Crossflow Dust Collector Figure 3 MCB Installation Detail 44 10360 0001 ...

Page 10: ...t wall bracket only has one See Figure 5 2 On the inlet side of all modules remove the top row of fasteners excluding the ones holding the trim strip in place Locate the top panel support bracket using the fasteners attach to each module 3 Starting at a corner lay the wall base channel in place squared to the unit and against the vertical corner channel Sections of the base channel should fit tigh...

Page 11: ...7 Revised 03 15 MCB Crossflow Dust Collector Figure 4 Motor Installation Diagram 44 10342 0001 ...

Page 12: ...8 Revised 03 15 MCB Crossflow Dust Collector Figure 5 MCB Booth Assembly 44 10361 0001 ...

Page 13: ...9 Revised 03 15 MCB Crossflow Dust Collector Figure 6 Booth Panel Interlock Connection ...

Page 14: ...ol DPC panel remove it from the box Instructions for mounting and connecting the panel are available in the DPM DPC Installation and Owner s Manual The panel should be installed within close proximity of the unit as shown in Figure 7 The DPM DPC panel requires field electrical connections 5 1 3 FINAL CONNECTIONS FOR ALL GAUGE OPTIONS For all pulse control panels connect the black plastic pressure ...

Page 15: ...11 Revised 03 15 MCB Crossflow Dust Collector Figure 7 MCB Pressure Gauge Installation 44 10350 0001 ...

Page 16: ... a pulse If the delivery capability of your compressed air source cannot return the manifold pressure to above 90 PSIG during the Pulse Delay factory set at 10 sec interval adjust the pulse delay at the timerboard and monitor the pressure A longer interval will raise the operating pressure which is the pulse delay Adjust from position 2 or position 3 on the timerboard Allow sufficient time for the...

Page 17: ...13 Revised 03 15 MCB Crossflow Dust Collector Figure 8 Solenoid Wiring to Pulse Controls 61 10017 0001 REV B ...

Page 18: ...ng grease The recommended grease is Chevron SRI 2 Periodically inspect the fan wheel coupling mounting bolts for tightness Re tighten as necessary to ensure the fan wheel does not loosen and come in contact with and rub the inlet bell C A U T I O N Drawers may be heavy due to weight of collected dust 2 Replacement cartridge filters should be ordered when the differential pressure across the filter...

Page 19: ...l excessive pressure drop over 5 on filter monitor panel Compressed air supply problems Check incoming compressed air for proper pressure 90 110 PSIG 6 4 7 2 BAR pulse flow 1 7 SCF standard cubic feet 48 1 liters per pulse and pulse duration 100 milli seconds Correct any problems Pulse cleaning system not functioning properly Check incoming 110 115 VAC power to cleaning control panel Check for blo...

Page 20: ...16 Revised 03 15 MCB Crossflow Dust Collector 9 ILLUSTRATED PARTS 6 and 9 Foot Wide Module ...

Page 21: ...ER BOARD Not Shown SOLENOID ENCLOSURE 4 POSITION SOLENOID ENCLOSURE 6 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown LIGHTING FIXTURE 2 BULB FLUORESCENT FINISHING PLUG 2 1 4 DIA SCREW HEX WASHER 5 16 18 x 3 4 LG SWAGEFORM BLOWER WHEEL SIZE SPECIFIC TO UNIT BLOWER INLET CONE CONSULT UAS CARTRIDGE FILTER VIEW LABEL ON END OF FILTER AND CONSULT UAS 1 4 NYLON TUBING FITTIN...

Page 22: ...18 Revised 03 15 MCB Crossflow Dust Collector 11 ILLUSTRATED PARTS 3 Foot Wide Module ...

Page 23: ...OSURE 2 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown FINISHING PLUG 2 1 4 DIA SCREW HEX WASHER 5 16 18 x 3 4 LG SWAGEFORM BLOWER WHEEL BLOWER INLET CONE CARTRIDGE FILTER VIEW LABEL ON END OF FILTER AND CONSULT UAS TUBE FITTING 90 DEG ELBOW I 8 NPT MALE x 1 4 TUBE PLUG PIPE 1 NPT BLACK IRON LATCH HANDLE INLET LOUVER DOOR BLOWER ASSEMBLY SEALANT GORE TEX CONSULT UAS 02...

Page 24: ...authorized repairs or modifications UAS makes no warranty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANT...

Reviews: