background image

7

SOLUS-310R

21

8

25

(18)

32

31

26

30

31

45

42

41

36

37

39

48

46

51

55

57

56

58

62

60

64

65

66

67

53

52

35

73

72

50

05.20.2008

49

1

2

3

3A

7

30

29

28

31

43

24

10

10A

12

16

18

15

14

19

20

22

19

13

17

74

69

70

77

31

11

47A

70

1

40

3B

34

47

Pump Inlet

Hose

63

54

54A

Pump to 

Gauge Hose

9

23

{

32

68

Heat 

Recirculation

Hose

61

13A

15A

31

Bypass

Hose

44

78

Heater to 

Outlet Hose

Pump to 

Heater Hose

14A

Summary of Contents for SOLUS-310R

Page 1: ...ent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Use the machine indoors 3 Do not let the pump ru...

Page 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Page 3: ...e to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motor and the pump do not require any scheduled maintenance however the mot...

Page 4: ...d to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy manoeuvreing and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Page 5: ...icates that the heater is turned on Once the heater reaches temperature this light will go out Expect this light to be lit most of the time as you clean CARPET UPHOLSTERY SWITCH 5 This rocker switch a...

Page 6: ...NOTE the time that it will take for your solution to reach 125 F will vary with the temperature of the solution that you put into the tank the ambient temperature the amount of solution in your tank...

Page 7: ...3 52 35 73 72 50 05 20 2008 49 1 2 3 3A 7 30 29 28 31 43 24 10 10A 12 16 18 15 14 19 20 22 19 13 17 74 69 70 77 31 11 47A 70 1 40 3B 34 47 Pump Inlet Hose 63 54 54A Pump to Gauge Hose 9 23 32 68 Heat...

Page 8: ...Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2062 Solenoid pump pressure 120V 47A FP...

Page 9: ...is is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch...

Page 10: ...10 NOTES 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com SOLUS 310R...

Reviews: