background image

3

INSPECTION:

Carefully unpack and inspect the OASIS PLUS for shipping damage.  Each unit is tested and
inspected before shipment.  Any damage incurred is the responsibility of the carrier, who
should be notified immediately.

All cleaning and maintenance work should be completed before
using the Ozone machine.
Ozone treatment should be the final step in room maintenance.
NOTE: the air flowing into the machine must be clean and dry.
NOTE: if the air intake filter is dirty or missing warranty is voided.

OPERATION:

NOTE: OZONE IS A TOXIC GAS.  FOLLOW ALL SAFETY PRECAUTIONS.

1. Make certain all people, pets, and plants are out of area.  Close all windows and doors.

2. Make sure the filter in front of the cooling fan is installed and is clean.

3. Place the Oasis Plus unit on a shelf or tabletop as high as possible in the area to be treated.

4 Plug the power cord into a grounded, 3-prong outlet.

5. Set the timer to the desired length of time.  Momentarily pressing  the UP timer button for one second

will increase the time setting by one minute at a time.  Hold the button for 1 -3 seconds to change
the time value by two minutes per second.  Hold the button for longer than 3 seconds and the time
setting will change in 20 minutes increments.  The maximum time setting is 29:59 hours. After
reaching the maximum time, the timer will wrap back to 00:00 and then continue increasing. When
the time is being decreased and reaches 00:00, it will wrap to 29:59 and continue decreasing.

6. Select the desired power level:   25%; 50%; 75% 100%.  The Oasis Plus always defaults to 100%

when you plug it in.  When the output level is set to 100%, the machine makes ozone continuously
until the timer runs out or the OFF button is pressed.  At other power level settings, the machine will
produce ozone for the fraction of a minute the level is set at.  For example, if the output level is set to
75%, the machine will produce ozone for 75% (45 seconds) of each minute.  At 50%, ozone is
generated for 30 seconds of each minute, and at 25%, the ozone generation lasts for 15 seconds of
each minute.  On any setting other than 100%, the ozone generator will be cycling the ozone ON and
OFF.

7. Turn the unit on by pressing the ON button.  Leave the area immediately.

8. When treatment is complete, unplug the ozone machine and ventilate the area completely until all

smell of ozone is gone.  Do NOT allow people, pets, or plants back into the area until all smell of
ozone has dissipated.

Summary of Contents for OASIS-PLUS

Page 1: ...er Limited exposure can cause irritation to eyes throat and nose and it may cause nausea Do not re inhabit a treated area until it has been well ventilated Prolonged exposure can also affect certain o...

Page 2: ...it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Keep the cord away from heated surfaces To unplug grasp...

Page 3: ...inutes per second Hold the button for longer than 3 seconds and the time setting will change in 20 minutes increments The maximum time setting is 29 59 hours After reaching the maximum time the timer...

Page 4: ...cal contamination and odor in areas up to 40 000 FT3 Use the following times as a guideline Hotel Motel Room 20 60 Minutes Automobiles 20 30 Minutes Fire Flood Restoration 12 72 Hours For Automobiles...

Page 5: ...r FP242 7A Electrode Assembly FP241 8 Hose Clamp 198 9 Fan 2014 10 Lock nut 324 10A Bolt 8 32 X 2 1 2 323 11 Fan cover filter 2015A 12 Filter only 2015B 13 Screw 4 40 X 5 8 S S 328 14 Bracket for safe...

Page 6: ...D SCREW 16 GREEN 14 GA 16 1 2 GREEN 18 GA 9 65 12 12 GREEN 14 GA 9 1 4 146 334 320 320 3 PAIR 6 WIRES 147 64 BLACK 16 GA WASHER 1096 LOCKNUT 358 HIGH VOLTAGE ELECTRODE CHAMBER RING CONNECTOR 334 16 1...

Page 7: ...ugged in Check the outlet to make sure it has power in it Look at the circuit breaker on the bottom of the machine to make sure it has not tripped Check the internal safety switch to make sure it is a...

Page 8: ...8 NOTES OASIS PLUS 120V 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com...