4

Connect the priming hose to the machine, turn the pump ON (2) and prime the air out of the pump.

When the water is clear (no air in it) turn the pump off and remove the priming hose.  NOTE: if priming

is difficult, place the open end of the priming hose into the vacuum inlet hose barb, and turn the vacuum

on (6).  Use you hand to block the open area in the hose barb.  This will allow the pump and the

vacuum to work together to get the water moving.  Priming may take 20-60 seconds, and the solution

tank should be full.  Once the pump is primed, turn the pump and the vacuum off.   Remove the

priming hose.

5

Add liquid cleaning chemical, with a pH between 6 and 9, to the solution tank.

6

Attach the spray hose to the solution quick disconnect and the vacuum hose to the hose barb on

the recovery tank. Pull the hoses out of the reel.  Attach the other ends of the hoses to the

cleaning tool.

6

Allow the heat exchanger two minutes to reach operating temperature.  The red light (5) will go out

when the heater has reached operating temperature.  NOTE:  the red light will be on nearly all the

time as you clean.

7

Turn the pump on and set the pressure selection switch (3) to the desired spraying pressure 300 or

50 PSI).  Turn the vacuum on (6).

8

Begin cleaning using the correct hoses and tool.

9

Use defoamer in the recovery tank any time foaming occurs.

10 Monitor the water level in the solution tank.  Do not let the pump run dry.

11 When the solution tank gets low, turn the pump and the vacuum off, fill the solution tank, empty

and clean the recovery tank.

12 When finished with the job, remove any unused solution from the solution tank, and run a few

gallons of clean water through the system.  Drain the recovery tank by placing the dump hose over

a drain, or into a bucket, and remove the hose cap.  Disconnect the hoses from the cleaning tool,

and reel the hoses up onto the hose spool.

NOTE: to remove the reel, with the hoses, from the machine, pull the vacuum hose loose from the hose

barb on the front of the tank.   Disconnect the solution hose quick coupling.  Push the vacuum hose into the

center of the spool.  Grasp the spool  on both sides, and lift it off the machine.  NOTE: before servicing any

component in the base cabinet, the hoses and spool must be removed from the machine before the tanks

can be lifted open.

This unique, patented system is operated by a solid state circuit.  It will inform the operator when the two

cords are plugged into separate circuits by turning on the circuit locator light.  This helps to prevent tripping

circuit breakers.   NOTE:  if the green, circuit locator light does not illuminate when the cords are plugged in,

then both cords are on the same circuit.  Try other outlets with one of the cords until you get the locator

light to come on.   NOTE: if the bypass switch is turned on when both cords are on the same circuit, the

breaker in the wall may trip.

REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE

BALL FLOAT SHUT-OFF

When the recovery tank is full, the ball float will disable the vacuum suction.  This will prevent water from

entering the vacuum motor.  The float may not work properly if the vacuum inlet float filter is dirty or if
there is heavy foam in the tank

.

CAUTION:  to avoid vacuum motor damage, always make sure the float filter is clean and that the

ball can travel freely before you operate the machine.  Always use a defoamer any time foam is

present.

ELECTRIC CIRCUIT LOCATOR

Summary of Contents for KING COBRA 310-CSA

Page 1: ...ANTY 1 Always use a defoamer when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not...

Page 2: ...ed into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cor...

Page 3: ...en 6 and 9 to avoid premature wear of the pump seals and or other components Damage caused by the use of strong chemicals is not covered by the warranty MAINTENANCE For optimum performance flush the m...

Page 4: ...INDICATES WHEN THE HEATER IS HEATING SELECT CARPET OR UPHOLSTERY 5 6 1 Inspect the machine hoses and cleaning tools for cleanliness and completeness 2 Fill the solution tank with water Using warm wate...

Page 5: ...m the solution tank and run a few gallons of clean water through the system Drain the recovery tank by placing the dump hose over a drain or into a bucket and remove the hose cap Disconnect the hoses...

Page 6: ...2 1 49 4 5 8 6 7 9 8 8 13 11 10 14 58 16 15 18 15A 17 19 54A 55 54 43 53 52 51 56 50 43 39 40 34 57 42 48 47 45 46 41 44 36 33 37 38 31 32 30 29 28 27 24 26 25 23 35 1 KC 310 120V 18A 12 20 20A 35A 3...

Page 7: ...power cord 35 45 Quick disconnect male 1 4 p t 35A 1146 Nipple S S 35B 1144 Tubing 4 3 4 36 910 Axle cut to length 21 37 2084 Wheel 10 38 27A Axle cap 39 923B Dual circuit sensor PCB 120V only 40 FP3...

Page 8: ...stage Ball float Positive displacement selectable pressure setting 140 Instant to 212 F 2000 Watts Stainless steel double bend twin tip 129 lbs SPECIFICATIONS KING COBRA 310 CSA 120V 425 322 0133 800...

Page 9: ...r emp cher d endommager le moteur d aspiration 2 Prot ger la machine de la pluie de la neige et des temp ratures extr mes la ranger dans un endroit chauff Utiliser la machine l int rieur Ne pas l util...

Page 10: ...tirer sur le cordon utiliser le cordon comme une poign e fermer un porte sur le cordon ou enrouler le cordon autour de bords ou de coins ac r s Ne pas faire passer la machine sur le cordon loigner le...

Page 11: ...afin demp cher l usure pr matur e de la pompe des joints d tanch it et autres composants La garantie ne couvre pas les dommages caus s par l utilisation de produits chimiques forts ENTRETIEN Pour une...

Page 12: ...LECTIONNER TAPIS OU MEUBLES CAPITONN S 5 6 1 Inspecter la machine les tuyaux flexibles et les outils de nettoyage pour v rifier si tout est propre et complet 2 Remplir d eau le r servoir solution Uti...

Page 13: ...n de toute solution inutilis e et faire couler plusieurs litres d eau claire dans le syst me Vidanger le r servoir de r cup ration en pla ant le tuyau de vidange au dessus d un drain ou dans un seau e...

Page 14: ...2 1 49 4 5 8 6 7 9 8 8 13 11 10 14 58 16 15 18 15A 17 19 54A 55 54 43 53 52 51 56 50 43 39 40 34 57 42 48 47 45 46 41 44 36 33 37 38 31 32 30 29 28 27 24 26 25 23 35 1 KC 310 120V 18A 12 20 20A 35A 3...

Page 15: ...ine S S 35B 1144 Tube 4 3 4 36 910 Essieu coup la longueur 21 37 2084 Roue 10 38 27A Chapeau d essieu 39 923B Capteur deux circuits carte de circuits imprim s 120V uniquement 40 FP336 Mont sur carte d...

Page 16: ...Garantie vie 7 2 po 3 tages Flotteur D placement positif pression r glable 140 po 356 cm Instant to 212 F 2000 watts Acier inox double courbure embout double 58 6 kg 129 lb SP CIFICATIONS KING COBRA 3...