background image

5

Daily

Monthly

Yearly

P

M

U

P

&

S

E

N

I

L

H

S

U

L

F

X

R

E

T

L

I

F

T

A

O

L

F

M

U

U

C

A

V

N

A

E

L

C

X

R

E

T

L

I

F

N

O

I

T

U

L

O

S

N

A

E

L

C

X

S

Y

A

W

R

I

A

T

E

L

N

I

K

C

E

H

C

X

E

N

I

H

C

A

M

E

L

A

C

S

E

D

X

S

E

H

S

U

R

B

R

O

T

O

M

M

U

U

C

A

V

K

C

E

H

C

X

MAINTENANCE

TROUBLESHOOTING

CHECK THIS

Solution tank is empty
Clogged spray tip
Pump not running
Valve on tool not operating

Solution path is clogged.  Pump only runs when spraying occurs
Solution tank may be empty, or nearly empty
No power to pump.  Test the switch.  Test the pump motor.

Partially clogged solution path (hose, heater, tool)
Worn pressure switch in pump.  Adjust pressure sensor in pump head.

Debris plugging cleaning tool or vacuum hose
Drain gate is not completely closed, or seals are damaged
Internal vacuum hose is cracked
Recovery tank lid is not closed, is cracked or gasket is damaged
Recovery tank is warped or cracked
Debris impeding air movement on vac motor impellors

No power to motor.  Test the switch. Test the vacuum motor.

IF PROBLEM OCCURS

NO SPRAY

PUMP
DOESN’T
RUN

PUMP

PULSATES

LOW

SUCTION

NO SUCTION

If you are unable to diagnose the problem,
contact the company from which you purchased your  Cobra-C2

Summary of Contents for COBRA-C2

Page 1: ...er regularly monthly or more often to prevent a build up of minerals or chemicals in the pump and heat systems Follow the flush with a clear water rinse to remove any particles and to rinse the acid f...

Page 2: ...sure to go to www usproducts com to register your warranty on line Do not leave the maching unattended when it is plugged in Unplug the unit from the outlet when not in use and before servicing To avo...

Page 3: ...float Shut OFF can also be accessed through this opening for maintenance Vacuum Inlet 5 This is where the vacuum hose attaches to the machine Latch 6 Open the latches to access the base compartment w...

Page 4: ...n the recovery tank any time foaming occurs 8 Monitor the water level in the solution tank Do not let the pump run dry 9 When the solution tank gets low turn off the pump fill the solution tank empty...

Page 5: ...ower to pump Test the switch Test the pump motor Partially clogged solution path hose heater tool Worn pressure switch in pump Adjust pressure sensor in pump head Debris plugging cleaning tool or vacu...

Page 6: ...7 9 12 10 15 17 18 18 3 20 25 21 22 40 41 42 43 44 45 46 47 48 49 58 50 51 52 62 69 14 16 66 COBRA C2 230 March 2007 19 56 11 12 13 14 30 61 60 59 58 69 57 55 54 53 29 64 56 1 6 5 3 2 4 8 22 23 30 30...

Page 7: ...p t 26 91 Elbow brass 1 4 n p t 27 2012 Hose 66 cm 28 108 Elbow Hose barb 29 925 Hose pump inlet 30 166 Hose Clamp 34 2017 Pump 100 psi 230V 40 270 Bolt 1 4 20 X 12 7 cm 41 137 Washer split lock 42 1...

Page 8: ...8 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com NOTES COB C2 230CEN A...

Reviews: